Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

14 results
Display

Tibial Base Plate for Total Knee Arthroplasty: Symmetric or Asymmetric?

Bozkurt M, Akkaya M, Tahta M, Gursoy S, Firat A

BACKGROUND: Ideal positioning and best coverage of the tibial base plate are essential in total knee arthroplasty. There are 2 types of tibial base plates: symmetric and asymmetric. The superiority...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture

Cho CH, Lee KJ, Song KS, Bae KC

Although extensor tendon rupture often occurs after volar plating for a distal radius fracture, a flexor tendon rupture is extremely rare. Most reported instances of flexor tendon ruptures after volar...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cortical Margining Capabilities of Fins Associated with Ventral Cervical Spine Instrumentation

Jin BH, Kwon HD, Cho YE

Fins incorporated into the design of a dynamic cervical spine implant have been employed to enhance axial load- bearing ability, yet their true biomechanical advantages, if any, have not been...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results

Lee SC, Jung KA, Nam CH, Jung SH, Hwang SH

BACKGROUND: This study examined the results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft as a surgical technique for the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
External Fixation Using Femoral Less Invasive Stabilization System Plate in Tibial Proximal Metaphyseal Fracture

Zhang J, Ebraheim N, Li M, He X, Liu J, Zhu L, Yu Y

BACKGROUND: The locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biplanar Open Wedge High Tibial Osteotomy in the Medial Compartment Osteoarthritis of the Knee Joint: Comparison between the Aescula and TomoFix Plate

Kyung HS, Lee BJ, Kim JW, Yoon SD

BACKGROUND: The purpose of this study was to compare the results of Aescula and TomoFix plates used for biplanar open wedge high tibial osteotomy in medial osteoarthritis of the knee...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Targon FN System for the Management of Intracapsular Neck of Femur Fractures: Minimum 2-Year Experience and Outcome in an Independent Hospital

Osarumwense D, Tissingh E, Wartenberg K, Aggarwal S, Ismail F, Orakwe S, Khan F

BACKGROUND: The Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation of Intertrochanteric Valgus Osteotomy with T Plate in Treatment of Developmental Coxa Vara

Elzohairy , Khairy HM

BACKGROUND: Although the valgus subtrochanteric osteotomy is considered as a standard surgical treatment for coxa vara, there is no consensus on the optimal method of fixation and osteotomy technique. Fixation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Operative Treatment of Clavicle Midshaft Fractures: Comparison between Reconstruction Plate and Reconstruction Locking Compression Plate

Cho CH, Song KS, Min BW, Bae KC, Lee KJ

BACKGROUND: To compare the outcomes of reconstruction plate and reconstruction locking compression plate (LCP) for the treatment of clavicle midshaft fractures. METHODS: Forty one patients with a clavicle midshaft fracture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of PEEK Cages and Plate Augmentation in Three-Level Anterior Cervical Fusion of Elderly Patients

Song KJ, Kim GH, Choi BY

BACKGROUND: To evaluate the clinical efficacy of three-level anterior cervical arthrodesis with polyethyletherketone (PEEK) cages and plate fixation for aged and osteoporotic patients with degenerative cervical spinal disorders. METHODS: Twenty one...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biomechanical Analysis of a Novel Wedge Locking Plate in a Porcine Tibial Model

Ha JK, Yeom CH, Jang HS, Song HE, Lee SJ, Kim KH, Chung KS, Bhat MG, Kim JG

BACKGROUND: The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Locking Plate for Proximal Humeral Fracture in the Elderly Population: Serial Change of Neck Shaft Angle

Pawaskar A, Lee KW, Kim JM, Park JW, Aminata IW, Jung HJ, Chun JM, Jeon IH

BACKGROUND: We conducted this radiographic study in the elderly population with proximal humeral fracture aiming to evaluate 1) the serial changes of neck-shaft angle after locking plate fixation and 2)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

Kim JH, Lee HJ, Kim J, Kim MB, Rhee SH, Gong HS, Lee YH, Baek GH

BACKGROUND: Distal radius fracture is the most common fracture of the upper extremity, and approximately 60,000 distal radius fractures occur annually in Korea. Internal fixation with an anatomical volar locking...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Is Anterior Bridge Plating for Mid-Shaft Humeral Fractures a Suitable Option for Patients Predominantly Involved in Overhead Activities? A Functional Outcome Study in Athletes and Manual Laborers

Mahajan AS, Kim YG, Kim JH, D'sa P, Lakhani A, Ok HS

BACKGROUND: To assess the functional and radiological outcomes of minimally invasive anterior bridge plating (ABP) for mid-shaft humerus fractures in patients predominantly involved in overhead activities (athletes and manual laborers). METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr