Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

58 results
Display

RE: Pediatric Novel Influenza A (H1N1) Virus Infection: the Imaging Findings

Wiwanitkit V

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

Dantas RV, Sarmento H, Duarte RM, Meireles Monte Raso SS, de Andrade AKM, Dos Anjos-Pontual ML

PURPOSE: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. MATERIALS AND METHODS: Specimens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Computer-Aided Diagnosis for Evaluating Lung Nodules on Chest CT: the Current Status and Perspective

Goo JM

As the detection and characterization of lung nodules are of paramount importance in thoracic radiology, various tools for making a computer-aided diagnosis (CAD) have been developed to improve the diagnostic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D Computer-Aided Detection for Digital Breast Tomosynthesis: Comparison with 2D Computer-Aided Detection for Digital Mammography in the Detection of Calcifications

Chu AJ, Cho N, Chang JM, Kim WH, Lee SH, Song SE, Shin SU, Moon WK

PURPOSE: To retrospectively evaluate the performance of 3D computer-aided detection (CAD) for digital breast tomosynthesis (DBT) in the detection of calcifications in comparison with 2D CAD for digital mammography (DM). MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

Kim JH, Cha JH, Kim N, Chang Y, Ko MS, Choi YW, Kim HH

  • KMID: 2319365
  • Ultrasonography.
  • 2014 Apr;33(2):105-115.
PURPOSE: The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). METHODS: Eighty-nine two-dimensional images (20 cysts, 42 benign...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nodule Detection in a Lung Region that's Segmented with Using Genetic Cellular Neural Networks and 3D Template Matching with Fuzzy Rule Based Thresholding

Ozekes S, Osman O, Ucan ON

OBJECTIVE: The purpose of this study was to develop a new method for automated lung nodule detection in serial section CT images with using the characteristics of the 3D appearance...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Value of Coronal Reformatted Images Using Multi-detector Computed Tomography for Nodal Staging in Non Small Cell Lung Cancer Cases

Shim YS, Choi SJ, Park CH, Lee JI, Kim HS, Park CH

PURPOSE: The aim of our study was to evaluate the value of coronal reformatted images using multi-detector computed tomography (MDCT) imaging in non small cell lung cancer (NSCLC) for the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fractal Dimension Analysis of MDCT Images for Quantifying the Morphological Changes of the Pulmonary Artery Tree in Patients with Pulmonary Hypertension

Haitao S, Ning L, Lijun G, Fei G, Cheng L

OBJECTIVE: The aim of this study was to use fractal dimension (FD) analysis on multidetector CT (MDCT) images for quantifying the morphological changes of the pulmonary artery tree in patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
New method of assessing the relationship between buccal bone thickness and gingival thickness

Kim YJ, Park JM, Kim S, Koo KT, Seol YJ, Lee YM, Rhyu IC, Ku Y

PURPOSE: The aim of this study was to determine the relationship between buccal bone thickness and gingival thickness by means of a noninvasive and relatively accurate digital registration method. METHODS: In...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Application of Helical Tomotherapy for Two Cases of Advanced Hepatocellular Carcinoma

Kim JS, You CR, Jang JW, Bae SH, Choi JY, Yoon SK, Kay CS

The role of radiotherapy in the treatment of hepatocellular carcinoma (HCC) has been limited to date, because the liver has a low tolerance to radiation. However, reconstructing tumors and surrounding...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of Dual-Energy CT with Non-Linear Blending on Abdominal CT Angiography

Li S, Wang C, Jiang X, Xu G

OBJECTIVE: To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Exophytic Benign and Malignant Hepatic Tumors: CT Imaging Features

Kim HJ, Lee DH, Lim JW, Ko YT, Kim KW

Our objective is to describe the CT features of exophytic hepatic tumors those may pose a diagnostic challenge because of the uncertainty of tumor origin. The beak sign and the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Multislice CT Virtual Intravascular Endoscopy for Assessing Pulmonary Embolisms: a Pictorial Review

Sun Z, Dosari SA, Ng C, al-Muntashari A, Almaliky S

Multislice CT has been widely used in clinical practice for diagnosing cardiovascular disease due to its reduced invasiveness and its high spatial and temporal resolution. As a reliable alternative to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pilot Study of Low-Dose Nonenhanced Computed Tomography With Iterative Reconstruction for Diagnosis of Urinary Stones

Park SH, Kim KD, Moon YT, Myung SC, Kim TH, Chang IH, Kwon JK

PURPOSE: To evaluate the efficacy of low-dose computed tomography (LDCT) for detecting urinary stones with the use of an iterative reconstruction technique for reducing radiation dose and image noise. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
CT Radiation Dose Optimization and Estimation: an Update for Radiologists

Goo HW

In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
18F-Fluorodeoxyglucose PET/CT in a Patient with Esophageal and Genital Leiomyomatosis

An YS, Kim DY

Diffuse esophageal leiomyomatosis is a rare benign tumor, which can be associated with leiomyoma in female genital tracts involving the uterus, vagina, and vulva. Alport syndrome, an inherited disorder that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

Qi W, Li J, Du X

OBJECTIVE: To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. MATERIALS AND METHODS: The image noise...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quantitative Analysis of the Effect of Iterative Reconstruction Using a Phantom: Determining the Appropriate Blending Percentage

Kim HG, Chung YE, Lee YH, Choi JY, Park MS, Kim MJ, Kim KW

PURPOSE: To investigate the optimal blending percentage of adaptive statistical iterative reconstruction (ASIR) in a reduced radiation dose while preserving a degree of image quality and texture that is similar...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Risk assessment of hepatocellular carcinoma development for indeterminate hepatic nodules in patients with chronic hepatitis B

Shin H, Jung YW, Kim BK, Park JY, Kim DY, Ahn SH, Han KH, Kim YY, Choi JY, Kim SU

BACKGROUND/AIMS: A risk prediction model for the development of hepatocellular carcinoma (HCC) from indeterminate nodules detected on computed tomography (CT) (Rad(CT) score) in patients with chronic hepatitis B (CHB)-related cirrhosis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols

Ahn SJ, Hong SH, Chai JW, Choi JY, Yoo HJ, Kim SH, Kang HS

OBJECTIVE: To compare the image quality of shoulder CT arthrography performed using 120 kVp and 140 kVp protocols. MATERIALS AND METHODS: Fifty-four CT examinations were prospectively included. CT scans were performed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2025 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr