Toxicol Res.  2013 Jun;29(2):121-127.

Comparison of Toxicity and Deposition of Nano-Sized Carbon Black Aerosol Prepared With or Without Dispersing Sonication

Affiliations
  • 1Center for Chemicals Safety and Health Research, Occupational Safety and Health Research Institute, Daejeon, Korea. limch@kosha.net

Abstract

Nanotoxicological research has shown toxicity of nanomaterials to be inversely related to particle size. However, the contribution of agglomeration to the toxicity of nanomaterials has not been sufficiently studied, although it is known that agglomeration is associated with increased nanomaterial size. In this study, we prepared aerosols of nano-sized carbon black by 2 different ways to verify the effects of agglomeration on the toxicity and deposition of nano-sized carbon black. The 2 methods of preparation included the carbon black dispersion method that facilitated clustering without sonication and the carbon black dispersion method involving sonication to achieve scattering and deagglomeration. Male Sprague-Dawley rats were exposed to carbon black aerosols 6 hr a day for 3 days or for 2 weeks. The median mass aerodynamic diameter of carbon black aerosols averaged 2.08 microm (for aerosol prepared without sonication; group N) and 1.79 microm (for aerosol prepared without sonication; group S). The average concentration of carbon black during the exposure period for group N and group S was 13.08 +/- 3.18 mg/m3 and 13.67 +/- 3.54 mg/m3, respectively, in the 3-day experiment. The average concentration during the 2-week experiment was 9.83 +/- 3.42 mg/m3 and 9.08 +/- 4.49 mg/m3 for group N and group S, respectively. The amount of carbon black deposition in the lungs was significantly higher in group S than in group N in both 3-day and 2-week experiments. The number of total cells, macrophages and polymorphonuclear leukocytes in the bronchoalveolar lavage (BAL) fluid, and the number of total white blood cells and neutrophils in the blood in the 2-week experiment were significantly higher in group S than in normal control. However, differences were not found in the inflammatory cytokine levels (IL-1beta, TNF-alpha, IL-6, etc.) and protein indicators of cell damage (albumin and lactate dehydrogenase) in the BAL fluid of both group N and group S as compared to the normal control. In conclusion, carbon black aerosol generated by sonication possesses smaller nanoparticles that are deposited to a greater extent in the lungs than is aerosol formulated without sonication. Additionally, rats were narrowly more affected when exposed to carbon black aerosol generated by sonication as compared to that produced without sonication.

Keyword

Carbon black; Nano; Deposition; Toxicity

MeSH Terms

Aerosols
Animals
Bronchoalveolar Lavage
Carbon
Humans
Interleukin-6
Lactic Acid
Leukocytes
Lung
Macrophages
Male
Nanoparticles
Nanostructures
Neutrophils
Particle Size
Rats
Rats, Sprague-Dawley
Sonication
Soot
Tumor Necrosis Factor-alpha
Aerosols
Carbon
Interleukin-6
Lactic Acid
Soot
Tumor Necrosis Factor-alpha
Full Text Links
  • TR
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr