Tuberc Respir Dis.  1997 Aug;44(4):785-795.

Clinical Application of Serum CEA, SCC, Cyfra2l-1, and TPA in Lung Cancer

Abstract

BACKGROUND: Tumor markers have been used in diagnosis, predicting the extent of disease, monitering recurrence after therapy and prediction of prognosis. But the utility of markers in lung cancer has been limited by low sensitivity and specificity. TPA-M is recently developed marker using combined monoclonal antibody of Cytokeratin 8, 18, and 19. This study was conducted to evaluate the efficacy of new tumor marker, TPA-M by comparing the estabilished markers 8CC, CEA, Cyfra2 I - I in hmg cancer.
METHODS
An immunoradiometric assay of serum CEA, SCC, Cyfra2l-I, and TPA-M was performed in 49 pathologically confirmed lung cancer patients who visited Keimyung University Hospital from April 1996 to August 1996, and 29 benign lung diseases. Commercially available kits, Ab bead CM (Eiken) to CEA, SCC RIA BEAD (DAINABOT) to SCC, CA21-1 (TEE) to Cyfra21-1, arid TPA-M (DAIICHI) to TPA-M were used for this study.
RESULTS
The mean serum values of lung cancer group and control group were 10.05 +/- 38.39 micro/L, l.59+/-0.94 micro/L in CEA, 3.04+/-5.79 micro/L, 1.58+/-2.85 micro/L in SCC, 8.27+/-11.96 micro/L, 1.77+/-2.72 micro/L in Cyfra21-1, and 132.02+/-209.35 U/L, 45.86+/-75.86 U/t in TPA-M respectively. Serum values of Cyfra21-1 and TPA-M in lung cancer group were higher than control group (p<0.05). Using cutoff value recommended by the manufactures, that is 2.5 micro/L, in CEA, 3.0 micro/L in Cyfra21-1, 70.0 U/L in TPA-M, arid 2.0 micro/L in SCC, sensitivity and specificity of lung cancer were 33.3%, 786% in CEA, 50.0%, 89.7% in Cyfra2l-l, 52.3%, 89.7% in TPA-M, 23.8%, 89.3% in SCC. Sensitivity and specificity of nonsmall cell lung cancer were 36.1%, 78.1% in CIA, 50.1%, 89.7% in Cyfra2l-1, 53.1%, 89.7% in TPA-M, 33.8%, 89.3% in SCC. Sensitivity and specificity of small cell king cancer were 25.0%, 78.5% in CEA, 50.0%, 89.6% in Cyfra2l-1, 50.0%, 89.6% in TPA-M, 0%, 89.2% in SCC. Cutoff value according to ROC(Receiver operating characteristics) curve was l.25 micro/L in CEA, 1.5 micro/L in Cyfra2l-1, 35 U/L in TPA-M, 0.6 micro/L in SCC. With this cutoff value, sensitivity, specificity, accuracy and kappa index of Cyfra21-1 and TPA-M were Letter than CEA and SCC. SCC only was related with statistic significance to TNM stages, dividing to operable stages(TNM stage I to IIIA) and inoperable stages (IIIB and IV) (p<0.05). But no tumor markers showed any correlation with significance with tumor size(p>0.05).
CONCLUSION
Serum TPA-M and Cyfra21-1 shows higher sensitivity and specificity than CEA and SCC in overall lung cancer and nonsmall cell lung cancer those were confirmed pathologically. SCC has higher specificity in nonsmall cell lung cancer. And the level of serum SCC are significantly related with TNM staging.

Keyword

Lung cancer; TPA-M; Cyfra21-1; SOC

MeSH Terms

Carcinoma, Non-Small-Cell Lung
Diagnosis
Humans
Immunoradiometric Assay
Keratin-8
Lung Diseases
Lung Neoplasms*
Lung*
Neoplasm Staging
Prognosis
Recurrence
Biomarkers, Tumor
Keratin-8
Full Text Links
  • TRD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr