Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

21 results
Display

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

Kim KH, Choi J, Lee CH, Cho BJ, Kook MS

PURPOSE: To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Management of choroidal neovascularization following laser photocoagulation for central serous chorioretinopathy

Ha TW, Ham DI, Kang SW

Little is known about the natural history and management of choroidal neovascularization (CNV) which developed as a complication of laser photocoagulation for central serous chorioretinopathy (CSC). We experienced two patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dacryoscintigraphic Findings in the Children with Tearing

Kim HC, Cho AR, Lew H

PURPOSE: To investigate the diagnostic effectiveness of dacryoscintigraphy in children with tearing; to evaluate tear clearance rate as a diagnostic factor of dacryoscintigraphy in children with tearing; and to analyze...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Correlation of Routine Tear Function Tests and Conjunctival Impression Cytology in Dry Eye Syndrome

Kumar P, Bhargava R, Kumar M, Ranjan S, Kumar M, Verma P

PURPOSE: To establish the strength of the association between routine tear function tests and conjunctival impression cytology (CIC) and to determine whether they simulate the morphological and cytological changes that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Simple New Method for Identifying the Proximal Cut End in Lower Canalicular Laceration

Cho SH, Hyun DW, Kang HJ, Ha MS

PURPOSE: We report a simple and effective method of identifying the medial cut end of lower canalicular laceration cases. METHODS: Twenty-seven eyes with lower canalicular lacerations as a result...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship between the Retinal Thickness Analyzer and the GDx VCC Scanning Laser Polarimeter, Stratus OCT Optical Coherence Tomograph, and Heidelberg Retina Tomograph II Confocal Scanning Laser Ophthalmoscopy

Ma KT, Lee SH, Hong S, Park KS, Kim CY, Seong GJ, Hong YJ

PURPOSE: To assess the relationship between the retinal thickness analyzer (RTA) parameters, and those of the GDx VCC scanning laser polarimeter (GDx VCC), Stratus OCT optical coherence tomography (Stratus...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Correlation between Angle Kappa and Ocular Biometry in Koreans

Choi SR, Kim US

PURPOSE: To investigate normative angle kappa data and to examine whether correlations exist between angle kappa and ocular biometric measurements (e.g., refractive error, axial length) and demographic features in Koreans. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dark-room Prone-position Test for Intermittent Angle Closure

Kim TW, Park KH, Hong C

PURPOSE: To determine the efficacy and safety of the dark-room prone-position test (DRPT) for intermittent angle closure (IAC) and to investigate the correlation between A-scan ultrasound biometric measurements and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

Lee SY, Ha DW, Kook MS

We investigated the ability of the GDx-Nerve Fiber Analyzer (NFA) to discriminate between normal and early glaucomatous eyes among Korean individuals by reviewing the medical records of 217 consecutive subjects:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ocular Motility Disturbances in Orbital Wall Fracture Patients

Lee SH, Lew H, Yun YS

It is difficult to identify the exact cause of ocular motility disturbances in orbital wall fracture patients. By performing CT and ocular motility tests before and after surgery, this study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Pupillography Using Image Processing

Lee IB, Choi B, Park KS, Kim SS, Hwang JM

PURPOSE: Pupillary examination is an important objective method to diagnose lesions of the anterior visual pathways. However, errors and faults may easily alter the interpretation and value of the test...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anterior Chamber Measurements by Pentacam and AS-OCT in Eyes With Normal Open Angles

Yi JH, Lee H, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY

PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Laser Peripheral Iridotomy with Iridoplasty in Primary Angle Closure Suspect: Anterior Chamber Analysis by Pentacam

Lee JR, Choi JY, Kim YD, Choi J

PURPOSE: To compare conventional laser peripheral iridotomy (LPI) and LPI combined with laser peripheral iridoplasty in eyes with primary angle closure suspect (PACS) by assessment of anterior chamber dimensional changes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cost-Utility Analysis of Screening Strategies for Diabetic Retinopathy in Korea

Kim SW, Kang GW

This study involved a cost-utility analysis of early diagnosis and treatment of diabetic retinopathy depending on the screening strategy used. The four screening strategies evaluated were no screening, opportunistic examination,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship of Hypertropia and Excyclotorsion in Superior Oblique Palsy

Lee JJ, Chun KI, Baek SH, Kim US

PURPOSE: To evaluate the correlation between hypertropia and excyclotorsion in acquired superior oblique palsy (SOP). METHODS: Thirty-one patients with acquired unilateral SOP were recruited for this study. The torsional angle of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Internal and Total Optical Aberrations for 2 Aberrometers: iTrace and OPD Scan

Won JB, Kim SW, Kim EK, Ha BJ, Kim TI

PURPOSE: To compare and evaluate the total and internal aberrations measured by two aberrometers: the laser ray tracing aberrometer (iTrace, Tracey Technology) and the automatic retinoscope aberrometer (OPD Scan,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Higher-order Aberrations between Eyes with Natural Supervision and Highly Myopic Eyes in Koreans

Kim M, Lee YG, Seo KR, Kim EK, Lee HK

PURPOSE: To describe the characteristics and investigate the differences of higher-order aberrations (HOAs) between the eyes with a natural, uncorrected visual acuity (UCVA) of 20/12 and eyes with highly...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Oh JH, Kim YY

PURPOSE: To compare the ability of scanning laser polarimetry with variable corneal compensation (GDx-VCC) and Stratus optical coherence tomography (OCT) to detect photographic retinal nerve fiber layer (RNFL) defects. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer

Shin JY, Choi JS, Oh JY, Kim MK, Lee JH, Wee WR

PURPOSE: To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS: We recruited 26 patients who had received unilateral...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of OCT and HRT Findings Among Normal, Normal Tension Glaucoma, and High Tension Glaucoma

Shin IH, Kang SY, Hong S, Kim SK, Seong GJ, Tak MK, Kim CY

PURPOSE: To evaluate the relationship between optic disc and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina topography (HRT) in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr