Korean J Anesthesiol.  2002 Dec;43(6):698-703. 10.4097/kjae.2002.43.6.698.

Does Bispectral Index Monitoring Detect the Sedative Effect of Epidural Anesthesia?

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea. hyewonmd@unitel.co.kr

Abstract

BACKGROUND: Epidural anesthesia has been shown to a have direct sedative effect and to markedly reduce the amount of hypnotic agents required for sedation. A Bispectral Index (BIS) is a useful monitor of the level of sedation and loss of consciousness for several anesthetics including propofol. In this study, we investigated whether BIS monitoring could detect the sedative effect of epidural anesthesia during propofol induction.
METHODS
Twenty patients scheduled for elective lower abdominal surgery were included. A Target controlled infusion (target effect concentration 5micro gram/ml, induction time 3 min) of propofol was administered to the patients with or without epidural anesthesia (2% lidocaine 15 ml) at the L2-3 level. The OAA/S scale and BIS were evaluated 20 min after epidural injection. Hypnotic requirements of propofol were determined using loss of eye opening in response to verbal command as an endpoint. At the time of induction of hypnosis, the target concentration, target effect concentration and BIS were recorded.
RESULTS
Epidural lidocaine significantly decreased the hypnotic dose of propofol (1.0 +/- 0.2 micro gram/ml vs. 1.3 +/- 0.1 micro gram/ml; P = 0.0008), hypnotic calculated concentration (3.3 +/- 0.6 micro gram/ml vs. 4.1 +/- 0.3 micro gram/ml; P = 0.0007), and the hypnotic effect concentration (0.7 +/- 0.3micro gram/ml vs. 1.1 +/- 0.1 micro gram/ml; P = 0.0007). In the patients with epidural anesthesia, the OAA/S scale was decreased without a change of the BIS after epidural anesthesia and BIS recorded at the time of induction of hypnosis was much higher in patients with epidural anesthesia than in patients without epidural anesthesia (92.7 +/- 2.2 vs. 85.5 +/- 6.2; P = 0.0029)
CONCLUSIONS
Epidural anesthesia induced a sedative effect without a change of the BIS and then induced the hypnosis with lesser dose of propofol. At the time of hypnosis, a higher BIS was noticed with epidural anestheia. These results concluded that BIS monitoring could not detect the sedative effect induced with epidural anesthesia.

Keyword

Bispectral index; epidural anesthesia; lidocaine; propofol

MeSH Terms

Anesthesia, Epidural*
Anesthetics
Consciousness Monitors*
Humans
Hypnosis
Hypnotics and Sedatives*
Injections, Epidural
Lidocaine
Propofol
Unconsciousness
Anesthetics
Hypnotics and Sedatives
Lidocaine
Propofol
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr