Korean J Anesthesiol.  2004 Feb;46(2):164-169. 10.4097/kjae.2004.46.2.164.

Does Level of Sensory Block by Epidural Anesthesia Affect the Degree of Sedation?

Affiliations
  • 1Department of Anethesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.

Abstract

BACKGROUND
Epidural anesthesia has been shown to have a direct sedative effect, and to markedly reduce the hypnotic requirement of intravenous anesthetics. The purpose of this study was to investigate whether the level of sensory block by epidural anesthesia is related with the degree of sedation, and to the hypnotic requirement of propofol. In addition, we tested whether bispectral index (BIS) monitoring can quantify the sedative effects of epidural anesthesia.
METHODS
Thirty two patients scheduled for elective upper abdominal or lower extremity surgery were allocated into two groups. 2% lidocaine 15 ml was administered through an epidural catheter at the T9 T10 level (group T, n = 16) or at the L3-L4 level (group L, n = 16). Observer's assessment of alertness/sedation (OAA/S) and BIS were evaluated 20 min after the epidural injection. Hypnotic doses of propofol were then determined by evaluating the loss of open eyes in response to a verbal command as an end point while propofol was administered by target controlled infusion (target effect concentration 5microgram/ml, induction time 3 min). At the time of induction of hypnosis, the target effect concentration and BIS were recorded.
RESULTS
The average level of sensory block was up to T3 in group T, and up to T11 in group L. Compared with the group L, more decreases were noticed in group T in terms of the hypnotic dose of propofol (1.13+/-0.31 mg/kg vs. 1.67+/-0.36 mg/kg; P = 0.03). A decrease in the OAA/S scale from 5 to 4 was more frequently noticed in group T than in group L (93.7% vs. 12.5%, P < 0.05). BIS recorded at the time of induction of hypnosis was higher in group T than in group L (94.8+/-2.8 vs. 82.6+/-2.2; P < 0.001).
CONCLUSIONS
A higher sensory block observed in group T than in group L induced a more profound sedative effect and hypnotic induction with a lesser dose of propofol. These results support the condition that the level of sensory block by epidural anesthesia affects the degree of sedation. Moreover, BIS monitoring could not quantify the sedative effect induced by epidural anesthesia.

Keyword

epidural anesthesia; lidocaine; propofol; bispectral index; sedation

MeSH Terms

Anesthesia
Anesthesia, Epidural*
Anesthetics, Intravenous
Catheters
Humans
Hypnosis
Hypnotics and Sedatives
Injections, Epidural
Lidocaine
Lower Extremity
Propofol
Anesthetics, Intravenous
Hypnotics and Sedatives
Lidocaine
Propofol
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr