Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

34 results
Display

Dimensional stability and wettability of rubber impression materials

Kang CH, Vang MS

  • KMID: 1959716
  • J Korean Acad Prosthodont.
  • 1992 Aug;30(2):233-245.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wettability of titanium implants depending upon surface properties

Han YS, Shin SW

STATEMENT OF PROBLEM: When an implant is fixed, a fixture comes into contact with a tissue fluid. Adhesion of a tissue fluid to a surface of implant is various...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of various surface treatments for titanium on surface micro roughness, static wettability, fibronectin adsorption

Shin HS, Kim YS, Shin SW

  • KMID: 2000675
  • J Korean Acad Prosthodont.
  • 2006 Aug;44(4):443-454.
Purpose: This study aims to get the fundamental data which is necessary to the development direction of implant surface treatment hereafter, based on the understanding the surface structure and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wettability of denture relining materials under water storage over time

Jin NY, Lee HR, Lee H, Pae A

STATEMENT OF PROBLEM: Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE: Purpose of this study is to compare and evaluate wettability of nine...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS

Cho LR, Chung KH, Kim KN

  • KMID: 2196018
  • J Korean Acad Prosthodont.
  • 2000 Apr;38(2):191-199.
Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wet tability of impression...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wear Properties of Surface Modified Ultra-high Molecular Weight Polyethylene

Kim KT, Choi JB, Choi KW

  • KMID: 2199178
  • J Korean Orthop Res Soc.
  • 1998 Oct;1(2):167-173.
The wear debris of ultra-high molecular weight polyethylene (UHMWPE) used as a bearing material in total joint arthroplasty evokes a serious adverse biological reaction (osteolysis). In this study, therefore, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the contact angle and wettability of the dental stones

Cho LR, Chung KH, Kim KN

  • KMID: 1959470
  • J Korean Acad Prosthodont.
  • 2003 Feb;41(1):61-70.
The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wettability and cellular response of UV light irradiated anodized titanium surface

Park KH, Koak JY, Kim SK, Heo SJ

PURPOSE: The object of this study was to investigate the effect of UV irradiation (by a general commercial UV sterilizer) on anodized titanium surface. Surface characteristics and cellular responses were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect Of Abutment Materials And Surface Treatment On Rubber Base Impression

Jeong DJ, Yang HS

  • KMID: 2127533
  • J Korean Acad Prosthodont.
  • 2001 Apr;39(2):146-156.
The purpose of this study was twofold. One was to evaluate the wettability of 4 elastomeric impression materials on tooth and different kinds of filling materials. The other was to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wettability and drug delivery of functionally graded nano-micro porous titanium surface

Yun KD, Vang MS, Yang HS, Park SW, Park HO, Lim HP

  • KMID: 2118762
  • J Korean Acad Prosthodont.
  • 2008 Jun;46(3):307-319.
STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of various intraoral repair systems on the shear bond strength of composite resin to zirconia

Han IH, Kang DW, Chung CH, Choe HC, Son MK

PURPOSE: This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS: Thirty zirconia specimens were divided into three...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of saline soaking on the removal torque of titanium implants in rabbit tibia after 10 days

Park JH, Cho SA

PURPOSE: The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface analyses of titanium substrate modified by anodization and nanoscale Ca-P deposition

Lee JM, Kim CW, Lim YJ, Kim MJ

  • KMID: 2195635
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):795-804.
STATEMENT OF PROBLEM: Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Wettability for Ocular Prosthesis Depending on Different Kinds of Artificial Tear Eye Drops

Jang SR, Yun IS, Lim HS, Kook KH

PURPOSE: In this study we compared the surface wettability of ocular prosthesis and depositions depending on different types of artificial tear eye drops. METHODS: The artificial tear eye drops contain sodium...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
EFFECTOF SOLDERING CONDITION ON THE TENSILE STRENGTH TITANIUM SOLDER JOINT WITH 14K GOLD SOLDER

Choi JH, Kim TJ, Song KY, Park CW

  • KMID: 2118583
  • J Korean Acad Prosthodont.
  • 1997 Sep;35(3):566-576.
This study was performed to evaluate the tensile strength of solder joint in titanium and the wettability of 14K gold solder on titanium. Two pieces of titanium rod 30 mm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of various cleansing techniques on dentin wettability and its influence on shear bond strength of a resin luting agent

Munirathinam D, Mohanaj D, Beganam M

PURPOSE: To evaluate the shear bond strength of resin luting agent to dentin surfaces cleansed with different agents like pumice, ultrasonic scaler with chlorhexidine gluconate, EDTA and the influence of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Normal Conjunctival Goblet Cell Density in Korean Measured by Impression Cytology

Kim SD, Kim JK, Han HK

  • KMID: 2123070
  • J Korean Ophthalmol Soc.
  • 1992 May;33(5):427-435.
Conjunctival goblet cells are thought to be the main source of tear mucin, and it is believed that this mucin plays an important role on increasing the tear film stability...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Biocompatibility Evaluation of Hydroxyapaite·Titania Surface for Dental Implant

Kang MK, Bae SS

The objective of this study was to fabricate hydroxyapatite (HA) containing titania layer by HA blasting and anodization method to obtain advantages of both methods and evaluated biocompatibility. To fabricate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
DIMENSIONAL ACCURACY OF EPOXY RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS

Chang SK, Chang IT, Yim SH

  • KMID: 2118626
  • J Korean Acad Prosthodont.
  • 1999 Jun;37(3):383-394.
The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface Modification of Stent Material: Experimental Study of Adhesion and Migration of Human AorticEndothelial Cells on Stent Material

Lee MS, Park JW, Lee JH, Kwon EY, Hong IS, Kim YJ

PURPOSE: To evaluate the relative adhesion and migration rate of cultured human aortic endothelial cells onto modified stent material in vitro. MATERIALS AND METHODS: Flat 1 x 1cm square, stainless...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr