Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

49 results
Display

Comparative Study of Absorbable Suture Material and Nonabsorbable Suture Material in Micro - Vascular Anastomosis: An Experimental Study on 1 mm Diameter Arterial Anastomosis in the Garotid Artery of Rat

Bae DK, Yoo MC, Kim DW

The suture materials influence the success of microvascular anastomosis importantly. The purpose of this experiment is to observe the effect of absorbable suture material and nonabsorbable suture material in microvascular...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endoscopic Management of Gastrointestinal Leaks and Perforation with Polyglycolic Acid Sheets

Han S, Chung H, Park JC, Shin SK, Lee SK, Lee YC

Gastrointestinal (GI) leakage, fistulae, and perforations can be serious and life threatening. There has been a paradigm shift in the management approach of these conditions, from surgical to conservative, including...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Staple Line Coverage with a Polyglycolic Acid Patch and Fibrin Glue without Pleural Abrasion after Thoracoscopic Bullectomy for Primary Spontaneous Pneumothorax

Hong KP, Kim DK, Kang KH

BACKGROUND: This study was conducted to determine the efficacy of staple line coverage using a polyglycolic acid patch and fibrin glue without pleural abrasion to prevent recurrent postoperative pneumothorax. METHODS: A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fluorouracil-Polyglycolic Acid Composite as an Intraperitoneal Chemotherapeutic Agent

Noh SM

  • KMID: 2206576
  • J Korean Surg Soc.
  • 1999 Oct;57(4):475-481.
BACKGROUND: There is a great need for a new drug delivery system that provides higher sustained exposure of the anticancer drug to the peritoneal surface or lymphatics with a lower...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Iatrogenic Tracheal Posterior Wall Perforation Repaired with Bronchoscope-Guided Knotless Sutures Through Tracheostomy

Jung YC, Sung K, Cho JH

A 68-year-old man presented with a posterior tracheal wall injury caused by percutaneous dilatational tracheostomy. The wound was immediately covered with an absorbable polyglycolic acid sheet. Ten days after the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study

Khiste SV, Ranganath , Nichani AS

PURPOSE: The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. METHODS: Three suture materials...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tissue reactions to suture materials in the oral mucosa of beagle dogs

Kim JS, Shin SI, Herr Y, Park JB, Kwon YH, Chung JH

PURPOSE: The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tissue-Engineered Tracheal Regeneration: Current Status

Shin YS

Tracheal regeneration is very challenging clinical demand because the trachea is not a simple windpipe, but a multilayered, complex structure. The tissue-engineering technique is widely accepted as promising strategy in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Role of Bioabsorbable Plates and Screws in Genioplasty

Chung SM, Kim SY, Chang SC

  • KMID: 2119715
  • J Korean Soc Plast Reconstr Surg.
  • 2001 Jan;28(1):49-53.
The use of bioabsorbable fixation system for the craniomaxillofacial surgeon has become available for prevention of intracranial migration, growth restriction by metal implants in pediatric patients as well as palpability...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical study of guided bone regeneration of extracted socket with PLA/PGA membrane and silk fibroin membrane

Hwang WJ, Jeong SN, Kim YS, Pi SH, You HK, Chung CP, Shin HS

PURPOSE: This study was designed to compare the bond regeneratiom effects of treatment using silk fibroin membrane ( Nanogide-S (R)) resorbable barrier with control group treated by polyactic acid /...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Kidney Preserving Surgery in Renal Trauma:. Experience by Early Vascular Approach Technique

Lee JB, Hwang SG, Moon JC

  • KMID: 2290061
  • Korean J Urol.
  • 1998 Oct;39(10):972-976.
PURPOSE: To evaluate the usefulness and safety of unified technique of vascular control before renal exposure in reconstructive surgery of renal trauma. MATERIALS AND METHODS: From July 1995 to June...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

Kim YM, Lee JH

BACKGROUND: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS),...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Engineered Tissue for Augmentation Penoplasty Using Chondrocytes and Biodegradable Polymers

Park HJ, Kwon CH

  • KMID: 2292301
  • Korean J Urol.
  • 2001 Aug;42(8):864-869.
PURPOSE: Materials used in penoplasty have several disadvantages upto now. It would be attractive to make enough tissue without any drawbacks for plastic surgery from autologous tissue. In this study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Absorbable Plate-Related Infection after Facial Bone Fracture Reduction

Choi SH, Lee JH

Absorbable plates are used widely for fixation of facial bone fractures. Compared to conventional titanium plating systems, absorbable plates have many favorable traits. They are not palpable after plate absorption,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparative Study of Tensile Strength in Vitro and Histologic Reaction on Rabbits between TRISORB Suture Materials and Traditional Suture Materials ( Dexon , Vicryl , Medifit )

Jeong SM, Doo JK

  • KMID: 2075574
  • Korean J Obstet Gynecol.
  • 1997 Oct;40(10):2217-2222.
Objective: Our purpost was to study effectiveness and clinical application of TRISO-RB suture materials and the find the most appropriate coating ingredient. The tensile str-ength and histologic reaction of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of poly(lactide-co-glycolide) (PLGA) on bone regeneration in rabbit calvaria

Park JY, Hwang WJ, Jeong SN, Kim YS, Pi SH, You HK, Shin HS

PURPOSE: The purpose of this study is to histologically and histomorphometrically evaluate the effect of PLGA on bone regeneration compared with bone graft material. METHODS:The experimental study was conducted in 10...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Sutureless Gastroduodenostomy

Kim JY, Lee JI, Jeong JH

  • KMID: 2372697
  • J Korean Gastric Cancer Assoc.
  • 2002 Mar;2(1):29-32.
A gastroduodenostomy is the most physiological reconstruction after a distal gastrectomy. However, a gastroduodenostomy with either sutures or staples has many complications. These include bleeding, leakage and stenosis. A sutureless...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Osteosynthesis using bioabsorbable skeletal fixation system in facial bone fracture

Kim YS, Lew DH, Lee HK, Park BY

  • KMID: 2119451
  • J Korean Soc Plast Reconstr Surg.
  • 1998 Aug;25(6):1053-1059.
In the practice of modern craniomaxillofacial surgery, there is a general agreement in favor of obtaining solid bony union through the use of titanium and vitallium rigid fixation. These metallic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Esophageal Stricture Prevention after Endoscopic Submucosal Dissection

Jain D, Singhal S

Advances in diagnostic modalities and improvement in surveillance programs for Barrett esophagus has resulted in an increase in the incidence of superficial esophageal cancers (SECs). SEC, due to their limited...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Stainless Steel Foreign body in the Knee Joint With Synovitis: A Case Report

Lee YT, Kim SJ, Kim HJ, Kang JH

  • KMID: 2105208
  • J Korean Orthop Assoc.
  • 1997 Dec;32(7):1531-1535.
A foreign body reaction to biodegradable fixation materials for internal fixation of a variety of fractures and osteotomies has been described since nineteen eighty five. Polyglycolide and other biodegradable poly-alpha-hydroxyacids...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr