Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

57 results
Display

3D Multislice CT Angiography in Post-Aortic Stent Grafting: A Pictorial Essay

Sun Z

Helical CT angiography has been widely used in both pre- and post-aortic stent grafting and it has been confirmed to be the preferred modality when compared to conventional angiography. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Low-Dose and Normal-Dose Gadobutrol in MR Renography and Renal Angiography

Bayrak IK, Ozmen Z, Nural MS, Danaci M, Diren B

OBJECTIVE: It has been advocated that a reduced injection volume with highly concentrated (1 M) contrast material can produce a sharper bolus peak and an increased intravascular first-pass gadolinium concentration...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
RE: Hemangiopericytoma of the Greater Omentum: A Potential Imaging Pitfall and Cause of Repeatedly Unsuccessful Angiographic Embolization

Virgilio E, Antonelli , Bocchetti , Balducci G

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

Song JS, Kwak HS, Chung GH

OBJECTIVE: We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simplified Correction of Ischemic Index in Diabetic Retinopathy Evaluated by Ultra-widefield Fluorescein Angiography

Kim JH, Jung HG, Chung HJ, Lee K, Sohn J

PURPOSE: To develop a novel, simplified method for correcting the ischemic index of nonperfused areas in diabetic retinopathy (DR). METHODS: We performed a retrospective review of 103 eyes with naive DR...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility and Utility of Transradial Cerebral Angiograpy: Experience during the Learning Period

Kim JH, Park YS, Chung CG, Park KS, Chung DJ, Kim HJ

OBJECTIVE: We wanted to present our experiences for performing transradial cerebral angiography during the learning period, and we also wanted to demonstrate this procedure's technical feasibility and utility in various...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Incidence and Risk Factors for Rebleeding during Cerebral Angiography for Ruptured Intracranial Aneurysms

Lim YC, Kim CH, Kim YB, Joo JY, Shin YS, Chung J

PURPOSE: The purpose was to evaluate the incidence and risk factors for rebleeding during cerebral angiography in ruptured intracranial aneurysms. MATERIALS AND METHODS: Among 1896 patients with ruptured intracranial aneurysms between...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ultrawide-field Fluorescein Angiography for Evaluation of Diabetic Retinopathy

Kong M, Lee MY, Ham DI

PURPOSE: To investigate the advantages of ultrawide-field fluorescein angiography (FA) over the standard fundus examination in the evaluation of diabetic retinopathy (DR). METHODS: Ultrawide-field FAs were obtained in 118 eyes of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the Forearm Dominancy Artery for Invasive Vascular Procedure with 3D-CT Angiography

Ki SH, Choi JH

The aim of this study was to evaluate the vascular dominance in the forearm as a factor in determining the choice of invasive vascular procedures in arteries of the forearm,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
ICG-enhanced digital angiography and photocoagulation of choroidal neovascularization in age-related macular degeneration

Kim SH, Lee DE, Park YJ

Choroidal neovascular membranes are often poorly defined on fluorescein angiography because of fluorescein leakage or blockage of hyperfluorescence by overlying hemorrhage, lipid, turbid fluid, or pigment. Indocyanine green (ICG) is...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

Lee JJ, Chang YM, Kang DS

OBJECTIVE: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. MATERIALS AND METHODS: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Coronary Artery Imaging in Children

Goo HW

Coronary artery problems in children usually have a significant impact on both short-term and long-term outcomes. Early and accurate diagnosis, therefore, is crucial but technically challenging due to the small...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Incidence and Anatomy of Accessory Pudendal Arteries as Depicted on Multidetector-Row CT Angiography: Clinical Implications of Preoperative Evaluation for Laparoscopic and Robot-Assisted Radical Prostatectomy

Park BJ, Sung DJ, Kim MJ, Cho SB, Kim YH, Chung KB, Kang SH, Cheon J

OBJECTIVE: To help preserve accessory pudendal arteries (APAs) and to ensure optimal postoperative sexual function after a laparoscopic or robot-assisted radical prostatectomy, we have evaluated the incidence of APAs as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiation Dose Reduction without Compromise to Image Quality by Alterations of Filtration and Focal Spot Size in Cerebral Angiography

Kim DJ, Park MK, Jung DE, Kang JH, Kim BM

OBJECTIVE: Different angiographic protocols may influence the radiation dose and image quality. In this study, we aimed to investigate the effects of filtration and focal spot size on radiation dose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images

Cho YD, Kim KM, Lee WJ, Sohn CH, Kang HS, Kim JE, Han MH

OBJECTIVE: The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

Zhang JJ, Liu T, Feng Y, Wu WF, Mou CY, Zhai LH

OBJECTIVE: We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). MATERIALS AND METHODS: The coronary arteries...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility and Diagnostic Accuracy of Whole Heart Coronary MR Angiography Using Free-Breathing 3D Balanced Turbo-Field-Echo with SENSE and the Half-Fourier Acquisition Technique

Kim YJ, Seo JS, Choi BW, Choe KO, Jang Y, Ko YG

OBJECTIVE: We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic Performance of CT Angiography in Patients Visiting Emergency Department with Overt Gastrointestinal Bleeding

Kim J, Kim YH, Lee KH, Lee YJ, Park JH

OBJECTIVE: To investigate the diagnostic performance of computed tomography angiography (CTA) in identifying the cause of bleeding and to determine the clinical features associated with a positive test result of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Fundus Photography and Fluorescein Angiography in Nonarteritic Anterior Ischemic Optic Neuropathy and Optic Neuritis

Kim MK, Kim US

PURPOSE: We evaluated fundus and fluorescein angiography (FAG) findings and characteristics that can help distinguish nonarteritic anterior ischemic optic neuropathy (NAION) from optic neuritis (ON). METHODS: Twenty-three NAION patients and 17...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of Dual-Energy CT with Non-Linear Blending on Abdominal CT Angiography

Li S, Wang C, Jiang X, Xu G

OBJECTIVE: To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr