Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes

Kim M, Lee JM, Yoon JH, Son H, Choi JW, Han JK, Choi BI

OBJECTIVE: To evaluate the impact of the adaptive iterative dose reduction (AIDR) three-dimensional (3D) algorithm in CT on noise reduction and the image quality compared to the filtered back projection...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Which Phantom Is Better for Assessing the Image Quality in Full-Field Digital Mammography?: American College of Radiology Accreditation Phantom versus Digital Mammography Accreditation Phantom

Song SE, Seo BK, Yie A, Ku BK, Kim HY, Cho KR, Chung HH, Lee SH, Hwang KW

OBJECTIVE: To compare between the American College of Radiology (ACR) accreditation phantom and digital mammography accreditation phantom in assessing the image quality in full-field digital mammography (FFDM). MATERIALS AND METHODS: In...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy

Kim H, Park CM, Lee SM, Lee HJ, Goo JM

OBJECTIVE: To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom

Kim SJ, Choi CG, Kim JK, Yun SC, Jahng GH, Jeong HK, Kim EJ

OBJECTIVE: To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Relationship between Subjective and Objective Parameters in CT Phantom Image Evaluation

Park HJ, Jung SE, Lee YJ, Cho WI, Do KH, Kim SH, Kim KH

OBJECTIVE: To evaluate whether there is a relationship between subjective parameters determined by a reviewer (spatial resolution, low contrast resolution, and artifacts) and objective parameters (the CT number of water,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Unmonochromatized Synchrotron Radiation and Conventional X-rays in the Imaging of Mammographic Phantom and Human Breast Specimens: A Preliminary Result

Jung H, Kim HJ, Kim EK, Hong JO, Je JH, Hwu Y, Tsai WL, Magaritondo G, Yoo HS

A simple imaging setup based on the principle of coherence-based contrast X-ray imaging with unmonochromatized synchrotron radiation was used for studying mammographic phantom and human breast specimens. The use of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Digital Tomosynthesis of the Chest: Comparison of Patient Exposure Dose and Image Quality between Standard Default Setting and Low Dose Setting

Hwang HS, Chung MJ, Lee KS

OBJECTIVE: To determine the optimum low dose (LD) digital tomosynthesis (DT) setting, and to compared the image quality of the LD DT with that of the standard default (SD) DT. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study

Lee MJ, Kim MJ, Yoon CS, Song SY, Park K, Kim WS

OBJECTIVE: Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Estimating the Absorbed Dose to Critical Organs During Dual X-ray Absorptiometry

Dizaji MM, Sharafi AA, Larijani B, Mokhlesian N, Hasanzadeh H

OBJECTIVE: The purpose of this study is to estimate a patient's organ dose (effective dose) during performance of dual X-ray absorptiometry by using the correlations derived from the surface dose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quantitative Analysis of the Effect of Iterative Reconstruction Using a Phantom: Determining the Appropriate Blending Percentage

Kim HG, Chung YE, Lee YH, Choi JY, Park MS, Kim MJ, Kim KW

PURPOSE: To investigate the optimal blending percentage of adaptive statistical iterative reconstruction (ASIR) in a reduced radiation dose while preserving a degree of image quality and texture that is similar...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Optimization of the Scan Protocol for the Reduction of Diaphragmatic Motion Artifacts Depicted on CT Angiography: a Phantom Study Simulating Pediatric Patients with Free Breathing

Baek JH, Lee W, Chang KH, Chung JW, Park JH

OBJECTIVE: This study was designed to optimize the scan protocol of CT angiography to reduce diaphragmatic motion artifacts in pediatric patients with free-breathing. MATERIALS AND METHODS: A phantom with twelve...
CITED
export Copy
Close
SHARE
Twitter Facebook