J Korean Radiol Soc.  1982 Dec;18(4):865-871. 10.3348/jkrs.1982.18.4.865.

A study on correlation of roentgen pelvimetry and delivery mode in Korean primigravida

Abstract

Pelvimetry by Colcher-Sussman method was performed in 130 primigravida at Eul Ji hospital during the period ofFeb. 1977 to Sep. 1980. They were divided by mode of delivery retrospectively in 2 groups --- A group was 99cases who had vaginal delivery, and B group was 31 cases who have been delivered by cesarean section. Thecomparison was made between 2 groups by ANOVA test and X2 - test. The results were as followings. 1. Themeasurements of X-ray pelvimetry for 2 groups. (cm) A group B group 1. Pelvic inlet A-Pdiameter;12.80±0.9512.07±0.95 Transverse diameter;13.14±0.66 12.58±0.69 Mean diameter;12.97±0.55 12.33±0.62 2. Mid-pelvis A-Pdiameter; 12.29±0.86 11.62±0.88 Transverse diameter; 10.18±0.74 9.75±0.76 Mean diameter; 11.23±0.5510.69±0.57 3. Pelvis outlet A-P diameter; 7.76±1.07 7.68±1.18 Transverse diameter;10.19±0.79 9.43±0.80 Meandiameter ;8.94±0.73 8.60±0.68 4. Fetal head Average diameter; 10.43±0.38 10.64±0.40 All the measurementsdescribed above except for the A-P diameter of the pelvic outlet were significant between 2 groups by ANOVA test(p<0.05)