J Korean Radiol Soc.
1998 Jul;39(1):137-142.
Plugging the Biopsy Tract in Rabbit Liver: Gelfoam, Fibrin Sealant and NBCA
- Affiliations
-
- 1Department of Diagnostic Radiology, National Medical Center, Korea.
- 2Department of Radiology, Sung Ae General Hospital, Korea.
- 3Department of Pathology, National Medical Center, Korea.
- 4Department of Radiology, Chung-Ang University College of Medicine, Korea.
Abstract
-
PURPOSE: To evaluate the effect of plugging the biopsy tract in rabbit liver and the pathologic changes caused by plugging materials.
MATERIALS AND METHODS
Thirty-two New Zealand White rabbits were divided into four groups(eight rabbits in each) and compared with one another. They were labeled group A(control), B(gelfoam),C(fibrin sealant) or D(NBCA). The liver was exposed and biopsied with an 18G disposible biopsy gun. The inner Tru-cut needle was withdrawn and plugging was undertaken through the outer cannula of the biopsy gun. Bleeding times of each material were compared. The rabbits were sacrificed and pathologically evaluated for 17 days.
RESULTS
Mean bleeding times were 46.7+/-34.5 sec in group A, 42.9+/-54.7 sec in group B, 12.6+/-15.0 sec in group C, and 0 sec in group D. In groups C and D, these results were statistically significant(p<0.01). Pathologically, fibrin sealant was lowest in foreign body reaction and fibrosis. NBCA was effective for the prevention of hemorrhage.
CONCLUSION
NBCA and fibrin sealant effectively plug the biopsy tract through the outer cannula of an18 G biopsy gun.