J Korean Neurol Assoc.  1992 Jun;10(2):188-196.

Clinical Studies on Electro-Oculography: Quantitative analysis of Smooth pursuit, OKN, and Bithermal Caloric test

Affiliations
  • 1Department Neurology, Hallym University.
  • 2Department Otorhinolaryngology, Hallym University.
  • 3Department of Neurology, Hanyang University.
  • 4Department of Neurology, Kyung-Hee University.
  • 5Department of Neurology, Seoul National University.

Abstract

Electrooculography (EOG or ENG) is the simplest and most readily available diagnostic tool for recording and quantitatively analysing the pathologic nystagmus, visually guided eye movements (saccades, pursuits, OKN) and Vestibular-ocular reflexes. By using our standard method, we analyzed the normal ranges of smooth pursuit velocity and its gain, slow component velocity of OKN, and the bitherrnal caloric response. Our results of ENG tests for normal controls would be used as a basic quantitative data in evaluating vestibular dysfunction, and ocular motility disorders.


MeSH Terms

Caloric Tests*
Electrooculography
Eye Movements
Nystagmus, Pathologic
Ocular Motility Disorders
Pursuit, Smooth*
Reference Values
Reflex