J Korean Acad Prosthodont.  2014 Apr;52(2):97-104. 10.4047/jkap.2014.52.2.97.

Comparative study on the radiopacity of different resin-based implant cements

Affiliations
  • 1Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University, Repubulic of Korea. wddc@korea.ac.kr

Abstract

PURPOSE
This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography.
MATERIALS AND METHODS
Four resin-based implant cements ((Estemp Implant(TM) (Spident, Incheon, Korea), Premier(R) Implant (Premier, Pennsylvania, USA), Cem-Implant(TM) (B.J.M lab, Or-yehuda, Israel), InterCem(TM) (SCI-PHARM, California, USA)) and control group (Elite Cement 100(TM) (GC, Tokyo, Japan)) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), Image J 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. RESULT: Among the 5 cements, Elite cement 100(TM) (control group) showed the highest radio-opacity in all thickness. In the experimental group, InterCem(TM) had the highest radio-opacity followed by Premier(R) Implant Cement(TM), Cem-Implant(TM) and Estemp Implant(TM). In addition, InterCem(TM) showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard.
CONCLUSION
Among the implant resin-based cements tested in the study, Premier(R) Implant Cement and Estemp Implant(TM) did not show appropriate radio-opacity. Only InterCem(TM) and Cem-Implant(TM) 0.5 mm specimen had the proper radiopacity and met the experiment standard.

Keyword

Radiopacity; Implant cement; Cement-type; Peri-implantitis

MeSH Terms

Aluminum
Berlin
California
Fungi
Incheon
National Institutes of Health (U.S.)
Pennsylvania
Peri-Implantitis
Radiographic Image Enhancement
Aluminum

Figure

  • Fig. 1. Metal mold for specimens.

  • Fig. 2. 99% Aluminum step wedge.

  • Fig. 3. Radiographic image of specimen and Aluminum step wedge. (A) 0.5 mm thickness, (B) 1.0 mm thickness, (C) 2.0 mm thickness.

  • Fig. 4. Aluminum wedge equivalent thickness values of experimental groups. ∗ : No significant difference.


Cited by  1 articles

A literature review on cementation of implant prosthesis
Eun-Suk Lee, Kyung-Ho Ko, Yoon-Hyuk Huh, Chan-Jin Park, Lee-Ra Cho
J Korean Acad Prosthodont. 2016;54(4):458-467.    doi: 10.4047/jkap.2016.54.4.458.


Reference

1.De Rouck T., Collys K., Cosyn J. Single-tooth replacement in the anterior maxilla by means of immediate implantation and pro-visionalization: a review. Int J Oral Maxillofac Implants. 2008. 23:897–904.
2.Lee A., Okayasu K., Wang HL. Screwversus cement-retained implant restorations: current concepts. Implant Dent. 2010. 19:8–15.
3.Chee W., Jivraj S. Screw versus cemented implant supported restorations. Br Dent J. 2006. 201:501–7.
Article
4.Chaar MS., Att W., Strub JR. Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review. J Oral Rehabil. 2011. 38:697–711.
Article
5.Michalakis KX., Hirayama H., Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants. 2003. 18:719–28.
6.Nissan J., Narobai D., Gross O., Ghelfan O., Chaushu G. Long-term outcome of cemented versus screw-retained implant-supported partial restorations. Int J Oral Maxillofac Implants. 2011. 26:1102–7.
7.Ramp MH., Dixon DL., Ramp LC., Breeding LC., Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent. 1999. 81:510–4.
Article
8.Koka S., Ewoldsen NO., Dana CL., Beatty MW. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: a pilot study. Implant Dent. 1995. 4:32–5.
Article
9.Clayton GH., Driscoll CF., Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants. 1997. 12:660–5.
10.Akça K., Iplikçioğlu H., Cehreli MC. Comparison of uniaxial resistance forces of cements used with implant-supported crowns. Int J Oral Maxillofac Implants. 2002. 17:536–42.
11.GaRey DJ., Tjan AH., James RA., Caputo AA. Effects of ther-mocycling, load-cycling, and blood contamination on cemented implant abutments. J Prosthet Dent. 1994. 71:124–32.
Article
12.Cho-Yan Lee J., Mattheos N., Nixon KC., Ivanovski S. Residual periodontal pockets are a risk indicator for peri-implantitis in patients treated for periodontitis. Clin Oral Implants Res. 2012. 23:325–33.
Article
13.Shapoff CA., Lahey BJ. Crestal bone loss and the consequences of retained excess cement around dental implants. Compend Contin Educ Dent. 2012. 33:94–6. 98–101.
14.Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol. 2009. 80:1388–92.
15.Dumbrigue HB., Abanomi AA., Cheng LL. Techniques to minimize excess luting agent in cement-retained implant restorations. J Prosthet Dent. 2002. 87:112–4.
Article
16.Schwedhelm ER., Lepe X., Aw TC. A crown venting technique for the cementation of implant-supported crowns. J Prosthet Dent. 2003. 89:89–90.
Article
17.Wadhwani C., Piñeyro A. Technique for controlling the cement for an implant crown. J Prosthet Dent. 2009. 102:57–8.
Article
18.Wadhwani C., Rapoport D., La Rosa S., Hess T., Kretschmar S. Radiographic detection and characteristic patterns of residual excess cement associated with cement-retained implant restorations: a clinical report. J Prosthet Dent. 2012. 107:151–7.
Article
19.Pauletto N., Lahiffe BJ., Walton JN. Complications associated with excess cement around crowns on osseointegrated implants: a clinical report. Int J Oral Maxillofac Implants. 1999. 14:865–8.
20.Gapski R., Neugeboren N., Pomeranz AZ., Reissner MW. Endosseous implant failure influenced by crown cementation: a clinical case report. Int J Oral Maxillofac Implants. 2008. 23:943–6.
21.O'Rourke B., Walls AW., Wassell RW. Radiographic detection of overhangs formed by resin composite luting agents. J Dent. 1995. 23:353–7.
22.Soares CJ., Santana FR., Fonseca RB., Martins LR., Neto FH. In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs. Clin Oral Investig. 2007. 11:331–6.
Article
23.Reis JM., Jorge EG., Ribeiro JG., Pinelli LA., Abi-Rached FO., Tanomaru-Filho M. Radiopacity evaluation of contemporary luting cements by digitization of images. ISRN Dent. 2012. 2012:1–5.
Article
24.Pette GA., Ganeles J., Norkin FJ. Radiographic appearance of commonly used cements in implant dentistry. Int J Periodontics Restorative Dent. 2013. 33:61–8.
Article
25.ISO 4049. Dentistry: Polymer-based restorative materials. Geneva: ISO International Organization for Standardization;2009.
26.Wadhwani C., Hess T., Faber T., Pin ̃eyro A., Chen CS. A descriptive study of the radiographic density of implant restorative cements. J Prosthet Dent. 2010. 103:295–302.
Article
27.Agar JR., Cameron SM., Hughbanks JC., Parker MH. Cement removal from restorations luted to titanium abutments with simulated subgingival margins. J Prosthet Dent. 1997. 78:43–7.
Article
28.Altintas SH., Yildirim T., Kayipmaz S., Usumez A. Evaluation of the radiopacity of luting cements by digital radiography. J Prosthodont. 2013. 22:282–6.
Article
29.Begoña Ormaechea M., Millstein P., Hirayama H. Tube angulation effect on radiographic analysis of the implant-abutment interface. Int J Oral Maxillofac Implants. 1999. 14:77–85.
30.Attar N., Tam LE., McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent. 2003. 89:127–34.
Article
31.Callan DP., Cobb CM. Excess cement and peri-implant disease. J Implant Adv Clin Dent. 2009. 1:61–8.
32.Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol. 2009. 80:1388–92.
Full Text Links
  • JKAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr