Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

111 results
Display

Reproducibility of Lateral Cephalometric Landmarks According to Radiographic Image Enhancement

Ryu HS, Hwang HS

  • KMID: 1976552
  • Korean J Orthod.
  • 2002 Feb;32(1):59-69.
The purpose of this study was to evaluate the reproducibility of lateral cephalometric landmarks according to radiographic image enhancement, and to contribute to the identification of cephalometric landmarks. Lateral cephalograms...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of digital image processing for noise reduction on observer performance

Jung YC, Choi BR, Huh KH, Yi WJ, Heo MS, Lee SS, Choi SC

  • KMID: 2034193
  • Korean J Oral Maxillofac Radiol.
  • 2010 Sep;40(3):103-107.
PURPOSE: This study was performed to examine the effects of image filter on observer performance by counting the number of holes at each wedge step on a radiographic image. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora(R)

Oh KR, Choi EH, Kim JD

  • KMID: 1537419
  • J Korean Acad Oral Maxillofac Radiol.
  • 1998 Aug;28(2):415-433.
Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient's exposure time and may...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Soft Copy Digital Mammography

Kim HH

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

Shin JW, Choi HM, Heo MS, Lee SS, Choi HB, Choi SC

  • KMID: 2034001
  • Korean J Oral Maxillofac Radiol.
  • 2002 Dec;32(4):213-220.
PURPOSE: Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques. During CR...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of digital noise reduction on the accuracy of endodontic file length determination

Mehdizadeh M, Khademi AA, Shokraneh , Farhadi N

PURPOSE: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An ROC study detecting ability of idiopathic pulmonary fibrosis using digital radiography

Chung EC, Im JG, Han MC, Kim JH

  • KMID: 2367257
  • J Korean Radiol Soc.
  • 1991 Mar;27(2):259-265.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study of digital and conventional radiography for the diagnostic ability of artificial proximal surface caries

Cho YG, Park SS

Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the image quality of digital radiography system and film-screen system; radiologists' rating ofthe visibility of normal anatomic

Song KS, Kim YG, Lee JB, Kim KS

Digital image aquisition and display is widely used in CT, ultrasonography, digital subtraction angiography, nuclear medicine and magnetic resonance image. But most of the radiological examinations performed in radiologydepartement are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array

Choi YN, Cho HM, Kim YS, An SJ, Kim HJ

  • KMID: 2243945
  • Korean J Med Phys.
  • 2010 Mar;21(1):9-15.
Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

Rovaris K, Vasconcelos KdF, do Nascimento EHL, Oliveira M, Freitas DQ, Haiter-Neto F

PURPOSE: The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Multispectral X-ray imaging to distinguish among dental materials

Peter AC, Schnaubelt M, Gente M

PURPOSE: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study

Kim SH, Suh TS, Choe BY, Lee HK

  • KMID: 2243960
  • Korean J Med Phys.
  • 2008 Dec;19(4):201-208.
Physical evaluations provide the basis for an objective and quantitative analysis of the image quality. Nonetheless, there are limitations in using physical evaluations to judge the utility of the image...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of image acquisition control of digital X-ray system on radiodensity quantification

Seong WJ, Kim HC, Jeong S, Heo Y, Song WB, Ahmad M

  • KMID: 2316840
  • Restor Dent Endod.
  • 2013 Aug;38(3):146-153.
OBJECTIVES: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

de Molon R, Morais-Camillo JAND, Sakakura C, Ferreira M, Loffredo L, Scaf G

PURPOSE: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. MATERIALS AND METHODS: Forty 2-wall bone...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary?

Naidoo K, Alazzawi S, Montgomery A

BACKGROUND: We investigated the value of using contrast as an additional aid to confirm the accuracy of needle placement for caudal epidural injections under intraoperative image intensifier guidance. METHODS: A total...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Storage Phosphor Digital Radiography in Portable Chest Imaging: Comparison of Image Quality with Conventional Film-Screen System with Variation of mAs

Park KJ, Ji H, Lee EJ, Chung KI, Suh JH

  • KMID: 2117278
  • J Korean Radiol Soc.
  • 1995 Dec;33(6):883-888.
PURPOSE: To compare image quality of storage phosphor digital radiography(DR) with film-screen radiography in portable chest imaging, and to assess the minimum X-ray dose that can be applied to DR in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A New Full-Field Digital Mammography System with and without the Use of an Advanced Post-Processing Algorithm: Comparison of Image Quality and Diagnostic Performance

Ahn HS, Kim SM, Jang M, Yun BL, Kim B, Ko ES, Han BK, Chang JM, Yi A, Cho N, Moon WK, Choi HY

OBJECTIVE: To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation the Reliability of Singh Index in Elderly Patients with Proximal Femoral Fractures Using Digital Radiographic Image

Yun HH, Kang JW, Lee GY, Lee JW, Lee JW, Jang HW, Park SC

  • KMID: 1455855
  • J Korean Orthop Res Soc.
  • 2010 Dec;13(2):60-67.
PURPOSE: To evaluate the reliability of Singh index (SI) values, determined on image software processed digital radiographs in elderly patients with proximal femoral fractures, with respect to its value as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Physical principles of digital radiographic imaging system

Choi JW, Yi WJ

  • KMID: 2074831
  • Korean J Oral Maxillofac Radiol.
  • 2010 Dec;40(4):155-158.
Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr