Korean J Ophthalmol.  1993 Dec;7(2):59-64. 10.3341/kjo.1993.7.2.59.

Superior oblique lengthening procedure with silicone expander in rabbits

Affiliations
  • 1Department of Ophthalmology, St. Mary's Hospital, Catholic University Medical College, Seoul, Korea.

Abstract

Using a rabbit model, we assessed the postoperative status and histopathologic findings of superior oblique tenotomy with silicone expander procedure. In the control group we marked and cut the superior oblique, and in the experimental group we inserted a silicone 240 retinal band 4 mm in length along the edges of incision. At the postoperative weeks 1,3,5 and 7, we randomly chose five rabbits and made a histopathologic examination after hematoxylin-eosin and Masson's trichrome stain. The distance between the incised edges was various in the control group, but constant in the experimental group. With time inflammation decreased and fibrosis of the superior oblique increased. Foreign body reaction occurred around the suture material in both groups., but not around the silicone expander. At 5 weeks atrophy of the superior oblique was observed in both groups.From the above results, we concluded that the superior oblique lengthening procedure using silicone expander is a useful surgical method for weakening the superior oblique muscle.

Keyword

lengthening procedure; superior oblique muscle; silicone expander; tenotomy

MeSH Terms

Animals
Female
Fibrosis
Male
Oculomotor Muscles/pathology/*surgery
Rabbits
*Silicone Elastomers
Tendons/pathology/*surgery
Silicone Elastomers
Full Text Links
  • KJO
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr