Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

32 results
Display

The Changes of Natural Frequency and Damping Coefficient of Disposable Pressure Transducer according to the Catheter Length and Time Assigned

Lim KJ, Kim D, Ahn W, Lee NJ

BACKGOUND: The accuracy of a disposable blood pressure transducer (DBPT) is determined by its physical properties: natural frequency (NF) and damping coefficient (DC). We planned this study to investigate whether...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Erroneously Recorded Esophageal Retrograde Peristalsis due to a Manometric Catheter Inadvertently Hooked in the Esophagus

Kim JY, Kim CY, Park SM, Park KH, Park JJ, Kim JS, Bak YT

  • KMID: 2304962
  • Korean J Gastrointest Motil.
  • 2003 Jun;9(1):59-61.
Esophageal retrograde peristalsis is known to be absent normally. This rare finding, if it happens, usually suggests a possibility that proximal ends of the manometric catheter are connected to the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Ginseng Extract on Blood Pressure and Intracranial Pressure in Cats

Kim KM, Chung HY

  • KMID: 2424920
  • J Korean Neurosurg Soc.
  • 1976 Jun;5(1):21-24.
There are two contradictive opinions of the therapeutic administration of Ginseng in the conditions of cerebrovascular accident and/or hypertensive heart diseases. This experimental study was performed to observe the effects...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Alpha-Chymotrypsin on the Outflow Facility in Rabbit Eyes

Chang BL, Youn WS

  • KMID: 1948585
  • J Korean Ophthalmol Soc.
  • 1968 Dec;9(4):1-6.
Alpha-chymotrypsin solutions, 200 unit/ml and 1,000 unit/ml, were injected into the anterior chamber of albino rabbit eyes fonowed by irrigation with normal saline after 3 minutes. Intraocular pressure was recorded...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Arterial Puncture Unrecognized by Pressure Waveform Monitoring after Central Venous Catheterization: A case report

Hwang WG, Kim GH

Central venous catheters are useful for acute hemodynamic monitoring, fluid resuscitation, drug administration, the aspiration of air embolism and total parenteral nutrition. However, various complications may occur during central venous...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An investigation into the effect of denture adhesives on incisal bite force of complete denture wearers using pressure transducers: a clinical study

Kalra P, Nadiger R, Shah FK

  • KMID: 2392035
  • J Adv Prosthodont.
  • 2012 May;4(2):97-102.
PURPOSE: Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Role of the Vestibular System on the Control of Blood Pressure in Rats

Park JC, Park OK, Park BL

BACKGROUND: The paired vestibular end organs lie within the semicircular canal of the inner ear in the temporal bones. It plays a role on the control of posture through the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Blast-Induced Hearing Loss

Cho SI

Blast injuries are increasing worldwide from combat and explosions in heavy industry. Primary blast injury is direct injury due to the high pressure effects and pressure differentials of the blast...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Biomechanical Analysis on Disc Pressure Distribution Changes with Interspinous Spinal Spacer Insertion for Lumbar Spinal Stenosis

Kwon SY, Jun SC, Moon SJ, Tack GR, Lee SJ, Shin KC

PURPOSE: To assess the biomechanical effects and effectiveness of an interspinous spinal spacer (ISS) on the intradiscal pressure using in vitro biomechanical tests. MATERIALS AND METHODS: Six calf spine specimens (less...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of Propofol or Thiopental on the Intracranial Pressure in the Patients for Transsphenoidal Approach

Shin YS, Jang JH, Lee KY, Chung SS

The effects of propofol and thiopental on the intracranial pressure (ICP) were investigated in forty, male or female adult patients with transsphenoidal approach for pituitary tumors. A 7-French epidural catheter...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes in Epidural Pressure during Genernal Anesthesia

Jung WS, Lee YM, Min HK, Cho IH, Choi Y, Chung SL, Lee C

BACKGROUND: Epidural pressure is reported to change in accordance with intracranial pressure (ICP). As ICP changes during general anesthesia, it is also possible that epidural pressure may change during general...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An experimental study on the diagnosis of esophageal ruptures by pressure change in the esophageal balloon

Song HY, Chung JY, Kuh JH, Kim BY, Chae SW, Park BC

  • KMID: 2348784
  • J Korean Radiol Soc.
  • 1992 Feb;28(1):1-7.
To make an accurate diagnosis of esophageal rupture during balloon dilatation without the help of esophagograph, an infusion pump, a pressure transducer and a radiopaque esophageal balloon were connected through...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes of Blood Gases, Plasma Catecholamine Concentrations and Hemodynamic Data in Anesthetized Dogs during Graded Hypoxia Induced by Nitrous Oxide

Kim SY, Song SO, Bae JI, Cheun JK, Bae JH

The sympathoadrenal system plays an important role in homeostasis in widely varing external environments. Conflicting findings, however, have been reported on its response to hypoxia. We investigated the effect of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanism of Action of Cholecystokinin on Colonic Motility in Isolated, Vascularly Perfused Rat Colon

Ko BS, Han JH, Jeong JI, Chae HB, Park SM, Youn SJ, Lee KY

  • KMID: 2326192
  • J Neurogastroenterol Motil.
  • 2011 Jan;17(1):73-81.
BACKGROUND/AIMS: It is generally believed that cholecystokinin (CCK) stimulates colonic motility, although there are controversial reports. It has also been suggested that postprandial peptide YY (PYY) release is CCK-dependent. Using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Nasal Airflow Pressure Monitoring and the Measurement of Airway Pressure Changes in Obstructive Sleep Apnea Syndrome and Upper Airway Resistance Syndrome

Kim H, Hong SB

  • KMID: 2317336
  • Sleep Med Psychophysiol.
  • 2000 Jun;7(1):27-33.
OBJECTIVES: The sensitivity and accuracy of thermistor airflow signal has been debated. The purposes of this study were to compare apnea-hypopnea index(AHI) detected from a conventional thermistor signal and a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Arterio-Venous Line Connection for Effective Intracardiac Deairing after Open Heart Surgery

Chung SW, Kim JW, Park JH

  • KMID: 1987628
  • Korean J Thorac Cardiovasc Surg.
  • 2003 Nov;36(11):834-838.
BACKGROUND: Deairing from the heart after open heart surgery(cardiopulmonary bypass) is a very important procedure. Artificial arteriovenous fistula was used to remove air, and the efficiency was evaluated by transesophageal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Immunohistochemical Study for Expression of cFos-like Protein Induced by Acute Hypotension in Rat Brain

Wi DH, Park JH

  • KMID: 2331236
  • J Korean Soc Emerg Med.
  • 1998 Dec;9(4):505-514.
BACKGROUND: It has been well known that cFos protein, one of the immediate-early gene proteins, was a cellular marker to characterize physiological or anatomical property of neural networks in mammalian...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spectral Analysis of Blood Pressure and Heart Rate Variability during Hemorrhage after Losartan Administration into the Lateral Ventricle

Lee DW, Kim KS, Kim HJ, Lee WJ

This study was aimed to elucidate the effect of intracerebroventricular losartan administration on arterial pressure regulation during hemorrhage in rats by power spectral analysis of blood pressure and heart rate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spectral Analysis of Heart Rate and Blood Pressure Variability during Hemorrhage in Thiopental-anesthetized Rats

Koo YH, Lee KH, Kim HJ, Hong JG

BACKGROUND: This study was aimed to elucidate the effect of thiopental anesthesia on circulatory response to hemorrhage in rats by power spectral analysis of heart rate and blood pressure variability. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Is Peak Penile Blood Flow Volume Velocity with Electromagnetic Blood Flowmeter Suitable for the Index of Penile Erection Evaluation in a Rat as Intracavernous Pressure?

Song YS, Park YH, Kim HG

  • KMID: 2292398
  • Korean J Urol.
  • 2002 Feb;43(2):169-174.
PURPOSE: The development of a new series drugs for treating erectile dysfunction presents the a need for an easy and inexpensive animal experimental models for evaluating the drug effects on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr