Korean J Anesthesiol.  2004 Mar;46(3):363-366. 10.4097/kjae.2004.46.3.363.

Arterial Puncture Unrecognized by Pressure Waveform Monitoring after Central Venous Catheterization: A case report

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

Abstract

Central venous catheters are useful for acute hemodynamic monitoring, fluid resuscitation, drug administration, the aspiration of air embolism and total parenteral nutrition. However, various complications may occur during central venous catheterization and the most common complication of the internal jugular approach is arterial puncture. Arterial puncture can be easily identified by a pulsatile blood flow and the bright red color of blood. It is usually confirmed by connecting catheter to a pressure transducer and observing venous waveforms and venous pressure. We experienced a patient in whom arterial cannulation was unrecognized by pressure recording, but was confirmed by blood gas analysis.

Keyword

arterial puncture; blood gas analysis; central venous catheter; complications; pressure monitoring

MeSH Terms

Blood Gas Analysis
Catheterization
Catheterization, Central Venous*
Catheters
Central Venous Catheters*
Embolism, Air
Hemodynamics
Humans
Parenteral Nutrition, Total
Punctures*
Resuscitation
Transducers, Pressure
Venous Pressure
Full Text Links