Effects of cementless fixation of implant prosthesis: A finite element study

Lee H, Park S, Kwon KR, Noh G

PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

Yi Y, Heo SJ, Koak JY, Kim SK

PURPOSE: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS: The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of different electronic torque drivers: A comparative evaluation

Ko BD, Son K, Kang SH, Lee KB

PURPOSE: This study aims to evaluate the loosening torque on the implant fixture, and to assess the accuracy of difference electronic torque drivers. MATERIALS AND METHODS: Three electronic torque drivers were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure

Chen B, Yang L, Lu Z, Meng H, Wu X, Chen C, Xie H

PURPOSE: Shear bond strength (SBS) test is the most commonly used method for evaluating resin bond strength of zirconia, but SBS results vary among different studies even when evaluating the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study

Findakly M, Jasim HH

PURPOSE: The aim of the study was to evaluate and compare the fracture resistance and modes of fracture of monolithic zirconia crowns with two preparation designs. MATERIALS AND METHODS: Forty human...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

Iturrate M, Lizundia E, Amezua X, Solaberrieta E

PURPOSE: The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close