Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

19 results
Display

Density Change of Local Anesthetics and a Mixed Solution Can Be Estimated by Refractometry

Hong JE, Park JC

BACKGROUND: Baricity of the local anesthetics is a major determinant of the distribution of local anesthetics in CSF. The purpose of this study was to assess the value...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Astigmatic Correlation between the Automated Refractometry and Dual Scheimpflug Analyzer in Pseudophakic Eyes

Park SH, Song IS, Seong MC, Cho HY, Kang MH

PURPOSE: To examine the relationship between the refractive astigmatism by automated refractometry and the corneal astigmatism by a dual Scheimpflug analyzer in pseudophakic eyes. METHODS: Prospectively, 75 patients (100 eyes) were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of Three Intraocular Lens-power Formulas in Predicting Refractive Outcomes in Different Intraocular Lenses

Kang SI, Moon K, Jun JH

PURPOSE: To compare the accuracy of different power-calculation formulas in predicting the postoperative refraction of three-piece and one-piece intraocular lenses (IOL). METHODS: We retrospectively reviewed the medical records of 74 eyes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Investigations on the effects of mouthrinses on the colour stability and surface roughness of different dental bioceramics

Soygun K, Varol O, Ozer A, Bolayir G

PURPOSE: In this study, three bioceramic materials, [IPS Empress CAD (Ivoclar), IPS e.max CAD (Ivoclar), and Lava Ultimate CAD (3M ESPE)] were treated with three commercial mouthrinses [Listerine, Tantum Verde,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship Between Corneal Curvatures and Refractive Error in Korea

Park CS, Kim JM

  • KMID: 2336469
  • J Korean Ophthalmol Soc.
  • 1988 Feb;29(1):35-40.
The purpose of this study was to detect the relationship between the diopters and corneal curvature. The objects were 752 eyes of 376 people (male 116, female 260) who visited...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Corneal Topographic Changes after Surgery in Epiblepharon Children

Baek SH, Heo NH, Lee KS

  • KMID: 2206191
  • J Korean Ophthalmol Soc.
  • 2002 Oct;43(10):1841-1846.
PURPOSE: This study was designed to evaluate the postoperative changes of astigmatism and corneal refractive power after surgical correction of epiblepharon using computerized topography. METHODS: The surgical data were investigated retrospectively...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Unique Red Blood Cell Morphology Detected in a Patient with Myelodysplastic Syndrome by Three-dimensional Refractive Index Tomography

Koo SE, Jang S, Park CJ, Cho YU, Park Y

The three-dimensional (3-D) shape of erythrocytes is strongly associated with various diseases. However, conventional optical imaging approaches with Wright's staining only provide information on two-dimensional morphology. Here, we employed optical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Optical characteristics of resin composite before and after polymerization

Eom AH, Kim DS, Lee SH, Byun CW, Park NH, Choi KK

OBJECTIVES: The aim of this study was to evaluate the optical characteristics such as color and translucency changes before and after light curing, to quantify the CQ and to measure...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Higher-order Aberrations in Pseudophakia with Different Intraocular Lenses

Kwon HL, Park HR, Koo BS, Kim TI

  • KMID: 2126184
  • J Korean Ophthalmol Soc.
  • 2005 Jun;46(6):954-960.
PURPOSE: To compare high-order aberrations in the pseudophakia with different types of intraocular lenses (IOLs), as well as with normal phakic eyes. METHODS: This single-center prospective study comprised 80 cataract...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Cataract Operation Using Iris Retractor in Congenital Microcoria

Park JH, Jin KH

PURPOSE: To report an case regarding phacoemulsification and intraocularlens (IOL) implantation using an iris retractor in a congenital microcoria patient. CASE SUMMARY: A 53-year-old male patient visited the office with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Corneal Topographic Changes after Horizontal Rectus Muscles Surgery

Paik HJ, Park SO

  • KMID: 2205658
  • J Korean Ophthalmol Soc.
  • 1999 Nov;40(11):3187-3194.
The refractive changes following extraocular muscles surgery are considered to be caused by corneal refractive changes which are caused by changes of tension on the globe after strabismus surgery. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Corneal Astigmatic Change in Corneal Topography After Upper Eyelid Surgery

Kang KH, Baek SH, Lee KS

  • KMID: 2206097
  • J Korean Ophthalmol Soc.
  • 2002 Jul;43(7):1113-1122.
PURPOSE: The study was conducted to determine if there is a corneal astigmatic changes after upper eyelid surgery by using corneal topography and if these changes are the reason why some...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of Astigmatic Correction Using Toric Intraocular Lens by Position and Size of Corneal Incision

Park W, Kim MS, Kim EC

PURPOSE: To assess the accuracy of toric intraocular lens (IOL) implantation by the location and size of the corneal incision. METHODS: We retrospectively reviewed the medical records of 98 patients (98...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In-vivo Optical Measurement of Neural Activity in the Brain

Kim SA, Jun SB

The optical neural recording techniques are promising tools in recent years. Compared to the traditional electrophysiological recording, the optical means offer several advantages including no inclusion of electrical noise, simultaneous...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Refractive Power on Retinal Volume Measurement Using Spectral Domain Optical Coherence Tomography

Lee M, Nam K, Lee S, Lee S

PURPOSE: To investigate the change of retinal volume according to anterior segment refractive power using contact lens by spectral domain optical coherence tomography (SD-OCT). METHODS: The retinal volume was measured using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Isosorbide Concentration in Perilymph of the Guinea Pig After Oral Administration Versus That After Round Window Perfusion

Kim M, Do KH, Kim KS

OBJECTIVES: The aims of this study were to investigate the feasibility of isosorbide delivery into perilymph through the round window membrane (RWM), and to compare the intracochlear isosorbide concentration in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of resin thickness on polymerization characteristics of silorane-based composite resin

Son SA, Roh HM, Hur B, Kwon YH, Park JK

OBJECTIVES: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. MATERIALS AND METHODS: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Scleral Fixation of Intraocular Lens and Retropupillary Fixation of Iris Claw Lens for Aphakic Eyes

Kim JY, Park CH, Whang WJ, Na KS, Kim HS

PURPOSE: To compare the efficacy and complications of scleral fixation of posterior chamber intraocular lens (IOL) and retropupillary fixation of iris claw IOL for dislocated IOL or aphakia without sufficient...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Quality Assurance Software for PRESAGE(REU) Gel Dosimetry

Cho W, Lee J, Kim HS, Wu HG

The aim of this study is to develop a new software tool for 3D dose verification using PRESAGE(REU) Gel dosimeter. The tool included following functions: importing 3D doses from treatment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr