Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

38 results
Display

Iopamidol Myelography

Kim SJ, Park HC, Kim YS

  • KMID: 2068279
  • J Korean Neurosurg Soc.
  • 1986 Sep;15(3):453-460.
In a comparative, prospective randomized study 200 patients underwent myelography using iopamidol (150 patients) or metrizamide (50 patients) as contrast medium. Adverse reactions were few, mild, and short in duration...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Clinical Trial of Iopamidol Myelography in 27 Cases

Yoo YR, Kim NK, Chung HY

  • KMID: 2068131
  • J Korean Neurosurg Soc.
  • 1983 Dec;12(4):589-597.
27 Myelographies with Iopamidol and 27 myelographies with metrizamide were performed in order to compare adverse reactions, radiographic quality and effects on vital signs of the two contrast media after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Microsurgical Posterolateral Approach for a Thoracic Disc Herniation

Kim SJ, Sung KH, Park SP, Doh JO

  • KMID: 1953130
  • J Korean Neurosurg Soc.
  • 1988 Dec;17(6):1441-1448.
The authors describe the case of a man who presented with T2-T3 disc herniation. The lesion was successfully identified by computed tomography with iopamidol myelogram and other radiological examinations. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of side effects in myelography with Iopamidol and Metrizamide

Lee Y, Kang HS, Chang KH, Han SH, Kwon OS, Myung HG

The study was conducted to compare the side effects in myelography of the two non-ionic water-soluble contrastmedias, Iopamidol(Niopam) and Metrizamide(Amipaque). A total of 111 patients were examined, 64 with Iopamidol...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Paired Comparison of Iopamidol and Iopromide in Hepatic Arteriography

Choi YH, Chung JW, Choi GM, Yoon CJ, Kim KH, Moon SG, Kim HC, Park JH

PURPOSE: To compare the clinical efficacy of iopamidol 370 and iopromide 370, as used in hepatic arteriography, in terms of their safety, patient tolerance, and image quality. MATERIALS AND METHODS: Between...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Phase III Clinical Trial Comparing Iopamidol 250 mgI/mL and Iopamidol 300mgI/mL in Cerebral Angiography: Multicenteric, Randomized and Double Blind Study

Seo H, Han MH, Kwon BJ, Im SH, Jung C, Kim SH, Kim JH

PURPOSE: To evaluate and compare the safety, tolerance and the image quality of cerebral angiography images with the use of the nonionic monomeric contrast agent, iopamidol at 250 mgI/mL or...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization

Gu MJ, Yi JH, Kim YH, Lee HJ, Kang UR, Ji SW

PURPOSE: This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Thoracic Disc Herniation Treated by Transthoracic Transpleural Approach

Kim MS, Lee IW, Jo TH, Song JU, Kim CK

  • KMID: 2068318
  • J Korean Neurosurg Soc.
  • 1987 Mar;16(1):297-303.
Thoracic disc herniation is uncommon and only represents 0.25% to 0.75% of all symptomatic disc lesions. The difficulty in diagnosis has been the one of the major problems in the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Myelography Induced Fatal Complications; Seizure and Rhabdomyolysis

Cha KC, Kim JH, Moon BG, Kang HI, Lee SJ

  • KMID: 2070926
  • Korean J Spine.
  • 2010 Sep;7(3):192-194.
Myelography has been generally regarded as a safe procedure. However, epidural hematoma and some allergic reactions have been reported, although rarely, as complications of myelography. Herein, we report a patient...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Aseptic Purulent Meningitis Complicating Niopam CT Cisternography

Lee DK, Yi SD, Park YC

  • KMID: 2065853
  • J Korean Neurol Assoc.
  • 1988 Jun;6(1):78-82.
Niopam is a newer, nonionic, watersoluble contrast medium used predominately in cisternographic and myelographic studies with metrizamide lately. The former has fewer, less severe and shorter adverse reactions than the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Delayed, Unusual Non-Cardiogenic Pulmonary Edema after Intravascular Administration of Non-Ionic, Low Osmolar Radiocontrast Media for Coronary Angiography

Kang MH, Nah JC

Non-cardiogenic pulmonary edema (NCPE) is a rare adverse reaction to iodinated radiocontrast media (RCM), in which all previous cases were immediate reactions. A 56-year-old male was given iopamidol, a non-ionic,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Efficacy of Iopamidol (Pamiray 370(R)) in Aortic and Extremity CT Angiography

Lee Y, Lee J, Lee HJ, Park J

PURPOSE: To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray(R)370) during an aortic and extremity CT angiography. MATERIALS AND METHODS: Between August and December of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiocontrast media-induced acute generalized exanthematous pustulosis: A safe administration of alternative radiocontrast media using patch tests

Kim SH, Lee SY, Choi YH, Kim CH, Hyun IK, Choi JH

Acute generalized exanthematous pustulosis (AGEP) is rarely caused by radiocontrast media (RCM). The role of skin tests for the diagnosis and evaluation of cross-reactivity in a delayed type of RCM-induced...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Local tissue reaction after injection of contrast media on gastric wall of mouse: experimental study for application of contrast media to computed tomography lymphography

Hwang SH, Kim HH, Park DJ, Jee YS, Lee KH, Kim YH, Lee HS, Lee HJ, Yang HK

PURPOSE: Computed tomography (CT) lymphography is a simple technique of sentinel node navigation but tissue reaction after injection of contrast media has not been reported yet. METHODS: Ninety mice used in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computed tomography of arachnoid cyst

Jung MG, Bae WT, Kim JK, Park JG, Kang HK, Chung HD

The preoperative diagnosis of intracranial arachnoid cysts has been simplified, and made more rapid andaccurate with CT. Using CT cisternography, detailed anatomic and phsiologic informations of arachnoid cysts couldbe obtained....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of the Suprasellar Arachnoid Cyst

Lee JK, Lee JC, Kim DW, Yim MB, Kim IH

  • KMID: 2068315
  • J Korean Neurosurg Soc.
  • 1987 Mar;16(1):277-282.
We report a case of the suprasellar arachnoid cyst with hydrocephalus which was incidental finding after minor head injury. Preoperatively, we studied the CT cisternography through lumbar route with niopam....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cinical Application of Iopamidol (Pamiray(R) 300) for Cerebral Angiography

Park SH, Suh SH, Kim J, Kim EY, Kim DJ, Lee SK, Kim DI

PURPOSE: The aim of this study was to assess the clinical safety and efficacy of Pamiray(R) 300 (Iopamidol; Dongkook Pharm., Seoul, Korea) as a nonionic contrast medium for cerebral angiography. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Utility of Iopamidol (Pamiray(R)370) for Cardiac CT

Kim MH, Choi S, Seon HJ, Kim YH, Kim JK, Park JG, Kang HK

PURPOSE: We evaluated the utility of iopamidol-based nonionic contrast media (Pamiray(R)370) for cardiac CT, with assessment of its image quality and safety. MATERIALS AND METHODS: The study included 100 patients who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Chronic Spontaneous Thoracic Spinal Epidural Hematoma: Case Report

Jo HR, Rho DS, Lee CR, Kim SC

  • KMID: 2187653
  • J Korean Neurosurg Soc.
  • 1989 Feb;18(2):331-338.
The spontaneous spinal epidural hematoma has a rare occurrence. Recently the authors have experienced a case of chronic spontaneous thoracic epidural hematoma in a 26 year old woman. She presented...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Preoperative Imaging of Sentinel Lymph Nodes in Gastric Cancer Using CT Lymphography

Hyung WJ, Kim YS, Lim JS, Kim MJ, Noh SH, Kim KW

PURPOSE: Preoperative identification of the sentinel lymph node (SLN) in gastric cancer (GC) patients may have great advantages for the minimally invasive treatment. This study was performed to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr