A review on the accuracy assessment methods of 3-dimensional digital dental models

Park JS, Lim YJ, Lee J, Kim B

The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions

Joo YH, Lee JH

PURPOSE: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Evaluation of Validity of Measurements using Digital Caliper and Three-dimensional Virtual Dental Models

Lee JH, Paik KS, Chang MS, Lee SP

  • KMID: 2030764
  • Korean J Anat.
  • 2004 Apr;37(2):209-218.
The measurement of tooth and the space analysis of dental study models are essential for precise diagnosis and treatment plan for orthodontic or prosthodontic cases. Traditionally, these have been done...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography

Kwon HJ, Kim KK, Yi WJ

PURPOSE: The objective of this study was to compare the accuracy of digital models from 3 dimentional (3D) optical scanner and cone beam computed tomography (CBCT). MATERIALS AND METHODS: We obtained...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the dental arch characteristics of bialveolar protrusion patients using a three-dimensional digital model

Lee SK, Kwon OW, Sung JH

  • KMID: 2273282
  • Korean J Orthod.
  • 2006 Feb;36(1):45-54.
Recent beauty trends have caused an increase in the number of bialveolar protrusion patients seeking treatment of lip protrusion. But studies of these patients are not common. Studies using their...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

Jiang T, Lee SM, Hou Y, Chang X, Hwang HS

OBJECTIVE: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

Kim JH, Kim KB, Kim WC, Kim JH, Kim HY

OBJECTIVE: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
2 cases of intracavitary radium moulding treatment with dental modeling compound for vaginal cancer

Yoon WK, Choi BS, Lee JU, Zang IJ

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

Jeong YG, Lee WS, Lee KB

PURPOSE: To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mixed-reality simulation for orthognathic surgery

Fushima K, Kobayashi

BACKGROUND: Mandibular motion tracking system (ManMoS) has been developed for orthognathic surgery. This article aimed to introduce the ManMoS and to examine the accuracy of this system. METHODS: Skeletal and dental...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Image fusion accuracy for the integration of digital dental model and 3D CT images by the point-based surface best fit algorithm

Kim BC, Lee CE, Park WS, Kang JW, Yi CK, Lee SH

  • KMID: 2005388
  • J Korean Assoc Oral Maxillofac Surg.
  • 2008 Oct;34(5):555-561.
PURPOSE: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps

Kim SH, Park YS, Kim MK, Kim S, Lee SP

PURPOSE: Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methods of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

Park JY, Kim D, Han SS, Yu HS, Cha JY

PURPOSE: This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The accuracy evaluation of digital surgical stents according to supported type

Lee J, Yoon M, Park T, Chun I, Yun K

PURPOSE: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. MATERIALS AND METHODS: 5 sets of dental models which have tooth supported...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the normal dental arch form of Korean adult

Chung HI

  • KMID: 2393199
  • Korean J Orthod.
  • 1972 Dec;3(1):7-13.
Many geometric curves are presented as representative form of normal dental arches by many authors; circle, ellipse, parabola or catenary curve. Among them those except circle seems difficult to be...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Construction of an ideal set-up model for lingual orthodontic treatment

Bae GS, Son WS

  • KMID: 1975957
  • Korean J Orthod.
  • 2005 Dec;35(6):459-474.
Making a precise and ideal set-up model is an essential part in the indirect bonding procedure for lingual orthodontic treatment. To evaluate the accuracy of the making a set-up model,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on morphologic characteristics of lingual surface of crown and lingual archform of Korean adult with normal occlusion

Kim YL, Sung JH

  • KMID: 2271183
  • Korean J Orthod.
  • 1995 Apr;25(2):209-221.
The purpose of this study was to obtain the lingual morphology(angulation, inclination, horizontal and vertical contour) and lingual arch form of Korean adult with normal occlusion in order to provide...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Maxillary first molar wear: a longitudinal study of children

Kim WH, Nam SE, Park YS, Lee SP

The aim of this study is to examine the correlation between tooth wear and age by quantitatively measuring maxillary first molar wear in children. A total of 150 maxillary dental...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

Han G, Li J, Wang S, Liu Y, Wang X, Zhou Y

OBJECTIVE: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. METHODS: Fourteen...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

Yun D, Choi DS, Jang I, Cha BK