Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

31 results
Display

Right ventricle perforation after Swan-Ganz catheterization in a patient undergoing CABG surgery: A case report

Kim JE, Kim DG, Koo MS, Kim GH, Kwon MY

We report an extremely rare case of right ventricle perforation by a Swan-Ganz catheter during open heart surgery. Even when pulmonary artery catheters are inserted with the utmost care, serious...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report

Sugiyama D, Ikeno S, Tsuchihashi T, Yokota S, Ina H, Kono T, Yamashita , Kawamata M

Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparisons of the Oxygen Saturation Between Right Atrial and Pulmonary Arterial Blood Immediately After Emergence from Cardiopulmonary Bypass During Open Heart Surgery in Pediatric Patients

Hwang JT, Yum KW, Ahn WS, Kim SD

BACKGROUND: Mixed venous oxygen saturation (SO2) monitoring turned out to be invaluable in following up systemic cardiovascular status. But balloon-tipped flow-directed thermodilution catheter (Swan-Ganz catheter) insertion carries additional inherent risks...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary Artery Catheterization and Mixed Venous Oximetry

Choi JM

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Central Venous Pressure, Diastolic Pulmonary Artery Pressure and Pulmonary Capillary Wedge Pressure and Pulmonary Capillary Wedge Pressure as Estimates of Left Atrial Pressure

Jo DH, Kim YJ, Kim YL

BACKGROUND: To evaluate the left heart function, left atrial pressure(LAP) has been monitored directly via LA catheter and indirectly via Swan-Ganz catheter. But indirect pressure monitor cannot often reflect the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Uncommon Complications Related to Pulmonary Artery Catheterization (CCOmbo Swan-Ganz catheter): Two case report

Park JY, Lee SJ, Choi IC

Case 1: A 30-year-old woman was scheduled for mitral valvuloplasty. A pulmonary artery (PA) catheter (Swan-Ganz CCOmbo model: 744HF75, Edwards(r), USA) was inserted via an introducer (8.5 Fr) placed in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Removal of Knotted Pulmonary Artery Catheter: A Case Report

Kim BI, Kim H, Son ST, Jung TY, Jung WS, Kim YH, Kang JH, Jee HO

  • KMID: 1915486
  • Korean J Thorac Cardiovasc Surg.
  • 1999 Mar;32(3):315-317.
The complications associated with the use of pulmonary artery catheter include dysrhythmias, heart block, pulmonary artery rupture, pulmonary infarction, endocardial damage, balloon rupture, arterial puncture, thromboembolism, air embolism, infection, pneumothorax,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A double-knotted pulmonary artery catheter with large loop in the right internal jugular vein: A case report

Yoon KS, Kim JA, Hong JI, Kim JH, Park SY, Choi SR

Knotting of a pulmonary artery catheter (PAC) is a rare, but well-known complication of pulmonary artery (PA) catheterization. We report a case of a double-knotted PAC with a large loop...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case Report of Primary Pericardial Malignant Epitheloid Mesothelioma

Chung MH, Hyun MS, Kim YJ, Shim BS, Kim CS, Lee DH, Lee CJ, Kang MS

Primary pericardial mesothelioma is a rare tumor of mesodermal origin that is infrequently diagnosed antemortem and survival is short. A 60 year old male case of pericardial mesothelioma (epitheloid type)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of IPV ( Intrapulmonary Percussive Ventilation ) on Cardiopulmonary Hemodynamics and Oxygenation in Dogs

Kim SD, Baik HJ, Kang H

To evaluate effects of IPV (Intrapulmonary Percussive Ventilation) on cardiopulmonary hemodynamics and oxygenation, we compared IPV with conventional IPPV (Intermittent Positive Pressure Ventilation} in eight mongrel dogs. After Swan-Ganz catheterization...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Persistent Left Superior Vena Cava Detected Incidentally after Pulmonary Artery Catheterization

Lee HJ, Kim N, Lee H, Shim JK, Song JW

We present a case of pulmonary artery catheter (PAC) placement through the right internal jugular vein, bridging vein and coronary sinus in a patient with previously unrecognized persistent left superior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
J-guide Wire Knotting during the Central Venous Catheterization: A case report

Kim SY, Jang YH

The purposes of central venous catheterization (CVC) are as followings, central venous pressure monitoring, pulmonary artery catheterization and monitoring, transvenous cardiac pacing, temporary hemodialysis, drug administration, rapid infusion of fluids,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes in the Sympathetic Activity after Percutaneous Mitral Balloon Valvuloplasty in Patients with Rheumatic Mitral Stenosis

Hong TJ, Ahn BJ

BACKGROUND AND OBJECTIVES: As mitral stenosis worsens, the cardiac output can be reduced, with a compensatory increase in the sympathetic nervous activity. An accelerated sympathetic nervous activity is responsible for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Systemic Hemodynamic and Renal Effects of Nicardipine Administration Followed by Supraceliac Aortic Cross Clamping and Unclamping in Experimental Dogs

Hong JH, Choe US, Bae JI, Kim JM, Kim AR, Jang YH

BACKGROUND: The incidence of renal insufficiency is reported about 18-27% during the thoracoabdominal aneurysm surgery. The possible mechanisms are reduction and maldistribution of renal blood flow, activation of renin angiotensin...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Transjugular Intrahepatic Portosystemic Shunt on Systemic Hemodynamics in Liver Cirrhosis

Baik SK, Kim YJ, Park JW, Suh JI, Kim JW, Park SJ, Kim HS, Lee DK, Kwon SO, Uh Y

  • KMID: 2084970
  • Korean J Gastroenterol.
  • 2001 Jan;37(1):21-25.
BACKGROUND/AIMS: We conducted this prospective study to identify whether hemodynamic changes occur immediately after transjugular intrahepatic portosystemic shunt (TIPS) in patients with liver cirrhosis and to find out the factors...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic and Therapeutic Impacts of Hemodynamic Data from Pulmonary Artery Catheterization in Critically Ill Patients

Bang EC, Koh SO, Nam SH, Kim JR, Cho HW

BACKGROUND: The hemodynamic status of critically ill patients is poorly predicted from clinical examination and chest x-ray findings, so equipments such as pulmonary artery catheter are needed for monitoring of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Congenital Pulmonary Vein Stenosis Diagnosed in an Infant with Recurrent Hemoptysis

Jung CW, Lee SY, Yu J, Kim BJ, Yun TJ, Ko JK, Hong SJ

  • KMID: 2314579
  • Pediatr Allergy Respir Dis.
  • 2007 Dec;17(4):434-439.
Congenital pulmonary vein stenosis is a rare cardiac malformation with a poor prognosis and is not easy to diagnose, because symptoms emerge in infants accompanying progressively worsening pulmonary hypertension. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Unusual venous route of pulmonary artery catheter in a liver transplant recipient: pericardiophrenic or highest intercostal vein?: a case report

Park JH, Sim KC, Lee S, Hwang GS

We report an extraordinary case in which the venous route for pulmonary artery catheterization was unusual. A 41 year-old woman with an end-stage liver disease underwent a living-donor liver transplantation....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recovery Trajectory in Tachycardia Induced Heart Failure Model

O JH, Park SI, Won JH, Kim EK, Lee CK

  • KMID: 1968887
  • Korean J Thorac Cardiovasc Surg.
  • 1999 May;32(5):422-427.
BACKGROUND: Tachycardia induced heart failure model would be the model of choice for the dilated cardiomyopathy. This more closely resembles the clinical syndrome and does not require major surgical trauma,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anesthetic considerations for a patient with situs inversus totalis undergoing cardiac surgery: A case report

Koo CH, Shim JK, Kim N, Ki Y, Park J, Kim JC

A 58-year-old male patient with situs inversus totalis, a rare congenital malformation characterized by all asymmetric organs being formed as the mirror images of their normal morphologies, underwent mitral valve...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr