Evaluation of the Long-Term Stability for the Cylindrical Ionization Chambers

Rah JE, Hong JY, Kim GY, Lim CI, Jeong HK, Shin DO, Suh TS

  • KMID: 2323581
  • J Korean Soc Ther Radiol Oncol.
  • 2006 Jun;24(2):138-143.
PURPOSE: To analyze the long-term stability of Farmer-type cylindrical ionization chambers by calibration factor provided from the KFDA (Korea Food Drug Administration) MATERIALS AND METHODS: The cylindrical ionization chambers used in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Acoustic Calibration of Clinical Audiometers Used for Special Periodic Health Examination

Kim KS, Won YL, Chung SY, Kang SK

  • KMID: 2141545
  • Korean J Occup Environ Med.
  • 2004 Dec;16(4):381-390.
OBJECTIVES: Various problems are encountered during audiometric testing. Deviation from reference threshold levels for supra-aural earphones is often a serious problem when hearing levels are measured. This paper reports the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Necessity of Reticulocyte Calibration for More Accurate and Precise Results

Lim YK, Chi HY, Lee MK, Kim HR

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Report of Present Status of Calibration for Domestic Radiation Measurements Instruments

Lim S, Choi J, An S, Cho KH, Lee SH, Lee R, Cho SJ

Periodical calibrations of radiation detectors are important for accurate quality assurance of therapeutic linac. The measuring instruments such as ion-chamber, thermometer, barometer, and survey meter should be calibrated periodically. Period...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Error Minimization of Respiratory Air Flow Measurement by Pneumotachometer

Cha EJ, Kang YK, Lee TS

  • KMID: 2329833
  • J Korean Soc Med Inform.
  • 2000 Mar;6(1):67-78.
Pneumotachometer is the most widely used respiratory air flow sensor. But the measurement error hard to be ignored exists, since the empirical calibration carve in a closed form cannot provide...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Practical Output Dosimetry with Undefined NdwCo-60 of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator

Oh YK, Choi TJ, Song JY

  • KMID: 2425223
  • Korean J Med Phys.
  • 2012 Jun;23(2):114-122.
For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor Nx or air kerma calibration factor Nk of air ionization...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Web-based Dosimetry Calibration Program for High Energy Radiation

Shin DO, Shin D, Kim SH, Park SY, Seo WS, Ahn HK, Kang JO, Hong SE

  • KMID: 2080297
  • Korean J Med Phys.
  • 2005 Sep;16(3):116-124.
Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma calibration factors, have somewhat complex formalism and limitations for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
High Dose Rate Ir-192 Source Calibration Method with Newly Designed Calibration Jig

Yi BY, Choi EK, Chang H

  • KMID: 2197214
  • J Korean Soc Ther Radiol.
  • 1989 Dec;7(2):299-304.
Authors have developed highly reproducible calibration method for the Micro-Selection HDR Ir-192 system(Nucletron, Netherland). The new jig has a 10cm radius circular hole in the 30cm x 30cm x 0.2cm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Validation of New Derivatization Procedure for the Determination of Hippuric Acid in Urine Using Gas Chromatography

Cho SH, Yim YH, Kim SM, Kwon HJ, Ha MN, Han SH

  • KMID: 2141608
  • Korean J Occup Environ Med.
  • 1995 Feb;7(1):58-62.
Urinary hippuric acid was analyzed by gas chromatography/mass spectrometry method. A simple and economical derivatization procedure using excessive methanol in acidic condition was adopted to esterify hippuric acid. Quantitative analysis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source

Huh HD, Choi JH, Choi SH, Kim SH, Kim WC, Kim HJ, Lee R, Kim KB, Hong SE, Shin DO

  • KMID: 2243974
  • Korean J Med Phys.
  • 2008 Dec;19(4):305-312.
The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Calibration and Radiation Survey of High Dose Rate Remote Afterloading System

Lee JO, Kang JK, Moon SR

  • KMID: 2196731
  • J Korean Soc Ther Radiol.
  • 1995 Mar;13(1):101-112.
High Dose Rate Remote Afterloading system was installed at Wonkwang Universi-ty Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Geometric Calibration Method for Triple Head Pinhole SPECT System

Kim JH, Lee JS, Lee WW, Park SY, Son JY, Kim YK, Kim SE, Lee DS

  • KMID: 2051928
  • Nucl Med Mol Imaging.
  • 2008 Feb;42(1):62-69.
PURPOSE: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Need for Cross-calibration of Body Composition Even with the Same Model of Dual-energy X-ray Absorptiometry

An SY, Choi YJ, Lee BJ, Chung YS

  • KMID: 2314125
  • Osteoporosis.
  • 2012 Dec;10(3):129-135.
OBJECTIVES: The purpose of this study was to compare total body fat mass, lean mass, and bone mineral content in addition to regional fat measured by the same model of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of clinical validation of acceleromyography and electromyography in children who were administered rocuronium during general anesthesia: a prospective double-blinded randomized study

Jung W, Hwang M, Won YJ, Lim BG, Kong MH, Lee IO

BACKGROUND: Electromyography and acceleromyography are common neuromuscular monitoring devices. However, questions still remain regarding the use of acceleromyography in children. This study compared the calibration success rates and intubation conditions...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam

Kim SH, Huh H, Choi SH, Choi J, Kim HJ, Lim C, Shin DO

  • KMID: 1989088
  • Korean J Med Phys.
  • 2009 Dec;20(4):317-323.
The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study on Short Term Test-Retest Reliability of High Frequency Audiometry

Park JY, Jung HS, Park HM, Moon IH, Jun BH

  • KMID: 2274298
  • Korean J Otolaryngol-Head Neck Surg.
  • 1997 Feb;40(2):240-245.
Although high frequency threshold has been regarded as a early detector of cochlear damage, there has been no standardized system for calibration or measurement of high frequency threshold. Compared measurement...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing

Kim MJ, Cho W, Kang YN, Suh TS

  • KMID: 1436555
  • Korean J Med Phys.
  • 2012 Mar;23(1):62-69.
The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams

Shin DO, Park SY, Ji YH, Lee CG, Suh TS, Kwon SI, Ahn HK, Kang JO, Hong SE

  • KMID: 2323821
  • J Korean Soc Ther Radiol Oncol.
  • 2002 Dec;20(4):381-390.
PURPOSE: To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Ultrasound Phantom for Volume Calibration

Kim HY, Lee JH, Lee KJ, Suh H, Lee R

  • KMID: 2243963
  • Korean J Med Phys.
  • 2008 Dec;19(4):227-230.
The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simulated Nystagmus Blockage Syndrome

Kim JK, Jhung JI, Lee JB

  • KMID: 1949883
  • J Korean Ophthalmol Soc.
  • 1993 Jun;34(6):545-548.
Manifest latent nystagmus (MLN) combined with esotropia may be confused with the nystagmus blockage syndrome (NBS), so the NBS may be overdiagnosed. The NBS is similar to MLN in the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close