Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

34 results
Display

Ultrafast Magnetic Resonance Imaging: Echo Planar Imaging and Spiral Scan Imaging

Ahn CB

  • KMID: 2099790
  • J Korean Soc Magn Reson Med.
  • 1999 Mar;3(1):6-12.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Improvement of Gibb

Ahn CB, Kim CY, Ryu WS, Oh CH, Yi Y, Shin JK

  • KMID: 1540733
  • J Korean Soc Magn Reson Med.
  • 1997 Dec;1(1):79-85.
Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple T2-weighed images. As results, intensities in k-space data are varying according to T2 decay,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dual Birdcage RF Coil for Leg MR Angiography

Yang YJ, Kim SK, Lee DR, Choi HJ, Bae SH, Kim HC, Ahn CB, Oh CH

  • KMID: 1540732
  • J Korean Soc Magn Reson Med.
  • 1997 Dec;1(1):75-78.
A dual birdcage RF coil is proposed for MRI and MRA of the human leg. The coil can be used to cover the whole human leg by imaging upper and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Computerized Neuropsychological Tests for Functional localization of Brain

Lee SH, Ahn CB, Park HJ

  • KMID: 2317332
  • Sleep Med Psychophysiol.
  • 1999 Dec;6(2):149-157.
A Computerzed Neuropsychological Test (CNT) system using multimedia and object oriented technologies are developed for clinical application in psychiatry. The developed system is composed of 14 neuropsychologial tests which are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D Printing Technology and Its Applications for Tissue/Organ Regeneration

Ahn CB, Son KH, Lee JW

Three-dimensional (3D) printing, also known as additive manufacturing (AM), has been used frequently in regenerative or translational medicine. In addition, recent advances in 3D printing technologies have opened the door...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Water-Fat Imaging with Automatic Field Inhomogeneity Correction Using Joint Phase Magnitude Density Function at Low Field MRI

Kim PK, Ahn CB

PURPOSE: A new inhomogeneity correction method based on two-point Dixon sequence is proposed to obtain water and fat images at 0.35T, low field magnetic resonance imaging (MRI) system. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
KAIS Resistive NMR-CT and Its Clinical Application

Kim SY, Eun TK, Lee JH, Cho ZH, Oh CH, Ahn CB, Park HW

This paper contains the results of cl inical studies with 0.1 and 0.15 Tesla KAIS NMR Tomograph which was developed by Korea Advanced 1 nstitute of 5cience. A variety of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Removal of Edge Artifact due to Partial Volume Effect in the Adaptive Template Filtering

Ahn CB, Song YC

  • KMID: 1560562
  • J Korean Soc Magn Reson Med.
  • 2000 Dec;4(2):120-127.
Adaptive template filtering has been proposed recently for enhancement of signal-to-noise ratio without loss of resolution. In the adaptive template filtering, an optimal template among multiple templates is selected, then...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fast Cardiac CINE MRI by Iterative Truncation of Small Transformed Coefficients

Park J, Hong HJ, Yang YJ, Ahn CB

PURPOSE: A new compressed sensing technique by iterative truncation of small transformed coefficients (ITSC) is proposed for fast cardiac CINE MRI. MATERIALS AND METHODS: The proposed reconstruction is composed of two...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
ECG gated magnetic resonance imaging in normal heart

Park JH, Park CS, Lim D, Im CK, Han MC, Kim CW, Ahn CB, Kim YS, Rew CY, Moon CW, Cho ZH

MR imaging of normal heart was done in 7 Volunteers who had no clinical evidence of cardiobascular disease,using KAIS 0.15 Tesla resistive magnet imaing system. Saturation recovery with spin echo...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
f-MRI with Three-Dimensional Visual Stimulation

Ahn CB, Kim CY, Park HJ, Oh SJ

  • KMID: 2330917
  • J Korean Soc Magn Reson Med.
  • 2005 Jun;9(1):24-29.
PURPOSE: Instead of conventional two-dimensional (2-D) visual stimuli, three-dimensional (3-D) visual stimuli with stereoscopic vision were employed for the study of functional Magnetic Resonance Imaging (f-MRI). In this paper f-MRI...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Distribution of Serotonin-2 Receptor in the Superior Collicullus of the Adult Rat: A Radioarutographic Study

Lee NK, Kim MH, Ahn CB

  • KMID: 2123146
  • J Korean Ophthalmol Soc.
  • 1993 Dec;34(12):1262-1268.
The superior colliculus is a laminated structure that consisted with superficial and deep layers in the roof of midbrain and the center of visual information and sensorimotor intergration. The deep...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Model-based Gradient Compensation in Spiral Imaging

Cho SH, Kim PK, Lim JW, Ahn CB

  • KMID: 1471614
  • J Korean Soc Magn Reson Med.
  • 2009 Jun;13(1):15-21.
PURPOSE: A method to estimate a real k-space trajectory based on a circuit model of the gradient system is proposed for spiral imaging. The estimated k-space trajectory instead of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study of Motion Effects in Cartesian and Spiral Parallel MRI Using Computer Simulation

Park SK, Ahn CB, Sim DG, Park H

  • KMID: 2144315
  • J Korean Soc Magn Reson Med.
  • 2008 Dec;12(2):123-130.
PURPOSE: Motion effects in parallel magnetic resonance imaging (MRI) are investigated. Parallel MRI is known to be robust to motion due to its reduced acquisition time. However, if there are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Blended-Transfer Learning for Compressed-Sensing Cardiac CINE MRI

Park SJ, Ahn CB

Purpose: To overcome the difficulty in building a large data set with a high-quality in medical imaging, a concept of 'blended-transfer learning' (BTL) using a combination of both source data...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Validity of the Domestic EEG and Mapping System(Neuronics)

Min SK, Jon DI, Lee SH, Ahn CB, Yoo SK

  • KMID: 2317283
  • Sleep Med Psychophysiol.
  • 1997 Jun;4(1):96-106.
The clinical validity of a korean EEG and EP mapping system(Neuronics) was evaluated with schizophrenic patients(n=20), normal controls(n=19), and 10 patients with central nervous system disease(8 patients with cerebrovascular accident,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cardiac Magnetic Resonance Imaging Using Multi-physiological Intelligent Trigger System

Park J, Yoon JH, Yang YJ, Ahn CB

PURPOSE: We proposed a multi-physiological signals based real-time intelligent triggering system(MITS) for Cardiac MRI. Induced noise of the system was analyzed. MATERIALS AND METHODS: MITS makes cardiac MR imaging sequence synchronize...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System

Kim PK, Lim JW, Ahn CB

  • KMID: 2206900
  • J Korean Soc Magn Reson Med.
  • 2007 Dec;11(2):95-102.
PURPOSE: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain

Yang YJ, Yoon JH, Baek HM, Ahn CB

PURPOSE: The effect of global inhomogeneity on quantitative susceptibility mapping (QSM) was investigated. A technique referred to as Simultaneous Unwrapping Phase with Error Recovery from inhomogeneity (SUPER) is suggested as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

Lim J, Won JY, Ahn CB, Kim J, Kim HJ, Jung JS

Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr