J Clin Neurol.  2021 Apr;17(2):307-316. 10.3988/jcn.2021.17.2.307.

Evaluation of Reproducibility of Brain Volumetry between Commercial Software, Inbrain and Established Research Purpose Method, FreeSurfer

Affiliations
  • 1Department of Radiology, Soonchunghyang University Bucheon Hospital, Bucheon, Korea
  • 2Department of Radiology, Hanyang University Medical Center, Seoul, Korea
  • 3Department of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan, Korea
  • 4Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
  • 5Department of Radiology, Asan Medical Center, Seoul, Korea
  • 6Departments of Neurology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
  • 7Departments of Psychiatry, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
  • 8Departments of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea

Abstract

Background and Purpose
We aimed to determine the intermethod reproducibility between the commercial software Inbrain (MIDAS IT) and the established research-purpose method FreeSurfer, as well as the effect of MRI resolution and the pathological condition of subjects on their intermethod reproducibility.
Methods
This study included 45 healthy volunteers and 85 patients with mild cognitive impairment (MCI). In 43 of the 85 patients with MCI, three-dimensional, T1-weighted MRI data were obtained at an in-plane resolution of 1.2 mm. The data of the remaining 42 patients with MCI and the healthy volunteers were obtained at an in-plane resolution of 1.0 mm. The within-subject coefficient of variation (CoV), intraclass correlation coefficient (ICC), and effect size were calculated, and means were compared using paired t-tests. The parameters obtained at 1.0-mm and 1.2-mm resolutions in patients with MCI were compared to evaluate the effect of the in-plane resolution on the intermethod reproducibility. The parameters obtained at a 1.0-mm in-plane resolution in patients with MCI and healthy volunteers were used to analyze the effect of subject condition on intermethod reproducibility.
Results
Overall the two methods showed excellent reproducibility across all regions of the brain (CoV=0.5–3.9, ICC=0.93 to >0.99). In the subgroup of healthy volunteers, the intermethod reliability was only good in some regions (frontal, temporal, cingulate, and insular). The intermethod reproducibility was better in the 1.0-mm group than the 1.2-mm group in all regions other than the nucleus accumbens.
Conclusions
Inbrain and FreeSurfer showed good-to-excellent intermethod reproducibility for volumetric measurements. Nevertheless, some noticeable differences were found based on subject condition, image resolution, and brain region.

Keyword

magnetic resonance imaging; reproducibility of results; mild cognitive impairment; brain; volumetry
Full Text Links
  • JCN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr