Arch Craniofac Surg.  2019 Mar;20(1):10-16. 10.7181/acfs.2018.02243.

Short-term changes of human acellular dermal matrix (Megaderm) in a mouse model

Affiliations
  • 1Department of Plastic and Reconstructive Surgery, Wonkwang University Hospital, Iksan, Korea. ycnadr@hanmail.net

Abstract

BACKGROUND
Physicians tend to overcorrect when applying the acellular dermal matrix for reconstructive option because of volume decrement problem after absorption comparing with initial volume. However, there are no studies on the exact volume decrement and absorption rate with commercial products in South Korea. To figure out absorption rate of acellular dermal matrix product in South Korea (Megaderm), authors designed this experiment.
METHODS
Nine mice were used and randomly divided into three groups by the time with sacrificing. The implant (Megaderm) was tailored to fit a cuboid form (1.0 cm× 1.0 cm in length and width and 2.0 mm in thickness). A skin incision was made at anterior chest with blade #15 scalpel with exposing the pectoralis major muscle. As hydrated Megaderm was located upon the pectoralis major muscle, the skin was sutured with Ethilon #5-0. After the surgical procedure, each animal group was sacrificed at 4, 8, and 12 weeks, respectively, for biopsies and histological analysis of the implants. All samples were stained with routine hematoxylin and eosin staining and Masson's trichrome staining and the thickness were measured. A measurements were analyzed using Friedman test. Statistically, the correlation between thicknesses of Megaderm before and after implantation was analyzed.
RESULTS
After sacrificing the animal groups at postoperative 4, 8, 12 weeks, the mean tissue thickness values were 2.10± 1.03 mm, 2.17± 0.21 mm, and 2.40± 0.20 mm (p= 0.368), respectively. The remaining ratios after absorption comparing with after initial hydrated Megaderm were 82.7%, 85.4%, and 94.5%, respectively. In histopathological findings, neovascularization and density of collagenous fiber was increased with time.
CONCLUSION
Author's hypothesis was absorption rate of implant would be increased over time. But in this experiment, there is no statistical significance between mean absorption thickness of implant and the time (p= 0.368). Also it can be affected by graft site, blood supply, and animals that were used in the experiment.

Keyword

Acellular dermal matrix; Alloderm; Megaderm; Surederm

MeSH Terms

Absorption
Acellular Dermis*
Animals
Biopsy
Collagen
Eosine Yellowish-(YS)
Hematoxylin
Humans*
Korea
Mice*
Nylons
Skin
Thorax
Transplants
Collagen
Eosine Yellowish-(YS)
Hematoxylin
Nylons
Full Text Links
  • ACFS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr