Korean J Thorac Cardiovasc Surg.  2000 Feb;33(2):146-150.

transprosthetic Pressure Gradient after aortic Valve Replacement with Small Sized Prostheses

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Dong Kwang Ju Hospital.
  • 2Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine.

Abstract

BACKGROUND: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. MATERIAL AND METHOD: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. RESULT: The mean pressure gradient and body surface area in each group were 21.7+/-10.2 mmHg and 1.52+/-0.14m2 in ATS 19mm 11.4+/-6.5 mmHg and 1,57+/-0.20m2 in M-H 20mm 15.2+/-6.3 mmHg and 1.54+/-0.13m2 in ATS 21mm 9.3+/-2.5 mmHg and 1.63 +/-0.14m2 in M-H 22 mm and 12.9+/-5.3 mmHg and 1.69+/-0.13m2 in ATS 23mm.
CONCLUSIONS
The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.

Keyword

Aortic valve, replacement; Echocardiography; Heart valve prosthesis

MeSH Terms

Aortic Valve*
Body Surface Area
Echocardiography
Follow-Up Studies
Heart Valve Prosthesis
Hemodynamics
Humans
Prognosis
Prostheses and Implants*
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr