Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

209 results
Display

Full mouth rehabilitation using removable prosthesis of patient with unstable mandible movements: A case report

Sohn DH, Yi YJ, Jo DW

Patients with collapsed occlusal support and unilateral chewing show parafunctional mandibular movements, which can be complicated in older patients. Gothic arch tracing and split cast technique are used to confirm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Retrospective Review of Radiographic and Clinical Findings from the M6 Cervical Prosthesis

Oltulu I, Korkmaz O, Sarıoğlu E, Aydoğan M

STUDY DESIGN: Retrospective clinical study. PURPOSE: To evaluate clinical results of the M6 cervical prosthesis. OVERVIEW OF LITERATURE: Cervical disk prostheses have been developed to preserve motion and reduce degeneration in adjacent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of cementless fixation of implant prosthesis: A finite element study

Lee H, Park S, Kwon KR, Noh G

PURPOSE: A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Prosthesis Design on Blood Loss in Simultaneous Bilateral Total Knee Arthroplasty: Closed-Box versus Open-Box Prosthesis

Rattanaprichavej P, Laoruengthana A, Rasamimogkol S, Varakornpipat P, Reosanguanwong K, Pongpirul

BACKGROUND: Various pre- and perioperative risk factors have been reported in association with blood loss in knee arthroplasty. However, the effect of the uncovered cancellous surface on blood loss in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A compact-sized surface EMG sensor for myoelectric hand prosthesis

Prakash A, Sharma S, Sharma N

Myoelectric prosthesis requires a sensor that can reliably capture surface electromyography (sEMG) signal from amputees for its controlled operation. The main problems with the presently available EMG devices are their...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ageing assessment of zirconia implant prostheses by three different quantitative assessment techniques

Kyaw PP, Pongprueksa P, Anuchitolarn W, Sirinukunwatta K, Suputtamongkol K

PURPOSE: To evaluate the influence of cyclic loading on phase transformation of zirconia abutments and to compare the effectiveness of three different quantitative ageing assessment techniques. MATERIALS AND METHODS: Thirty two...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Posterior single implant prosthesis using scannable healing abutment

Kim SM, Lee KB

Accurate impression taking for the success of implant prosthesis is a very important process. Methods of taking implant impression include the conventional method using impression coping and impression material, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area

Chae HS, Wang YK, Lee JJ, Song KY, Seo JM

PURPOSE: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Erratum: Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

Ku I, Lee GK, Park CY, Lee J, Jeong E

We have noticed two errors in our published paper above. In Fig. 3, the name of “Figure by courtesy of Sanho Yi” should be “Sangho Yi.” In Table 2, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D-Printed Prosthesis Replacement for Limb Salvage after Radical Resection of an Ameloblastoma in the Tibia with 1 Year of Follow Up: A Case Report

Feng D, He J, Zhang C, Wang L, Gu X, Guo Y

Ameloblastoma in the tibia is rare. Limb reconstruction after tumor resection is challenging in terms of selection of the operative method. Here, we report a case of radical resection of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

Kotanidis , Kontonasaki E, Koidis P

PURPOSE: The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with SiO2 nanoparticles. MATERIALS AND METHODS: Silica...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

Ku I, Lee GK, Park CY, Lee J, Jeong E

BACKGROUND: Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Use of digital scan data for evaluation of edentulous ridge relationship: A case report for removable prosthesis with unilateral cross bite

Kim JH, Kim JE, Park YB, Lee KW

After the teeth were extracted, maxillary and mandibular alveolar ridges show the opposite resorption pattern and as a result, the mandibular arch is enlarged than maxillary arch relatively. In this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report

Kim T, Lee JS, Hong SJ, Kim HS, Kwon KR

Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report

Park J, Kim JE, Park JM, Kim J, Shim JS

As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Use of an Extraoral Transfer Jig and a Handheld Face Scanner App for Integrating Face Scan Data into Prosthesis Design

Oh KC, Park JM

This article demonstrates a case that successfully rehabilitated the maxillary anterior missing tooth area with a single-tooth implant prosthesis by integrating three-dimensional face scan data into the computer-aided design software....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full Mouth Rehabilitation on Fixed Prosthesis with Implant in Oligodontia Patient

Hong JG, Chae HS, Kim KA, Ahn SG, Seo JM

The treatment of oligodontia is a minimally invasive method to preserve the remaining deciduous teeth and orthodontic space closure. However, it is difficult to obtain esthetic satisfaction, and long-term prognosis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report

Kee W, Park JH, Lim HP, Yun KD, Park SW

Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A prospective clinical of lithium disilicate pressed zirconia and monolithic zirconia in posterior implant-supported prostheses: A 24-month follow-up

Roh KW, Jeon YC, Jeong CM, Yun MJ, Huh JB, Lee SH, Yang DS, Bae EB

PURPOSE: The purpose of this study was to compare the clinical outcomes of lithium disilicate ceramic pressed zirconia prostheses and monolithic zirconia prostheses and to investigate the complications after two...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Completely Cast-Free, Digital Workflow for Fabricating an Implant-Supported Prosthesis with a New Coded Healing Abutment

Lee JH

The BellaTek Encode System introduced an innovative concept of a healing abutment-level impression. As the coded healing abutment is unscrewed only at the placement session, the mucosal barrier at an...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2023 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr