Ultrasonography.  2018 Jul;37(3):217-225. 10.14366/usg.17046.

Application of computer-aided diagnosis in breast ultrasound interpretation: improvements in diagnostic performance according to reader experience

Affiliations
  • 1Department of Radiology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Bucheon, Korea.
  • 2Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. gmlionmain@gmail.com

Abstract

PURPOSE
The purpose of this study was to evaluate the usefulness of applying computer-aided diagnosis (CAD) to breast ultrasound (US), depending on the reader's experience with breast imaging.
METHODS
Between October 2015 and January 2016, two experienced readers obtained and analyzed the grayscale US images of 200 cases according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon and categories. They additionally applied CAD (S-Detect) to analyze the lesions and made a diagnostic decision subjectively, based on grayscale US with CAD. For the same cases, two inexperienced readers analyzed the grayscale US images using the BI-RADS lexicon and categories, added CAD, and came to a subjective diagnostic conclusion. We then compared the diagnostic performance depending on the reader's experience with breast imaging.
RESULTS
The sensitivity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 91.7%, 75.0%, 75.0%, and 66.7%, respectively. The specificity values for the experienced readers, inexperienced readers, and CAD (for experienced and inexperienced readers) were 76.6%, 71.8%, 78.2%, and 76.1%, respectively. When diagnoses were made subjectively in combination with CAD, the specificity significantly improved (76.6% to 80.3%) without a change in the sensitivity (91.7%) in the experienced readers. After subjective combination with CAD, both of the sensitivity and specificity improved in the inexperienced readers (75.0% to 83.3% and 71.8% to 77.1%). In addition, the area under the curve improved for both the experienced and inexperienced readers (0.84 to 0.86 and 0.73 to 0.80) after the addition of CAD.
CONCLUSION
CAD is more useful for less experienced readers. Combining CAD with breast US led to improved specificity for both experienced and inexperienced readers.

Keyword

Ultrasonography; Breast neoplasms; Diagnosis, computer-assisted

MeSH Terms

Breast Neoplasms
Breast*
Diagnosis*
Diagnosis, Computer-Assisted
Information Systems
Sensitivity and Specificity
Ultrasonography*
Full Text Links
  • USG
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr