Maintaining the Constant Exposure Condition for an Acute Caenorhabditis elegans Mortality Test Using Passive Dosing

Affiliations
  • 1Department of Environmental Engineering, Ajou University, Suwon, Korea. jhkwon@ajou.ac.kr
  • 2Faculty of Environmental Engineering, University of Seoul, Seoul, Korea.

Abstract


OBJECTIVES
Maintaining the constant exposure to hydrophobic organic compouds in acute toxicity tests is one of the most difficult issues in the evaluation of their toxicity and corresponding risks. Passive dosing is an emerging tool to keep constant aqueous concentration because of the overwhelming mass loaded in the dosing phase. The primary objectives of this study were to develop the constant exposure condition for an acute mortality test and to compare the performance of the passive dosing method with the conventional spiking with co-solvent.
METHODS
A custom cut polydimethylsiloxane (PDMS) tubing loaded with benzyl butyl phthalate (BBP) was placed in each well of a 24-well plate containing assay medium. The rate of the release of BBP from PDMS was evaluated by measuring the change in the concentration of BBP in the assay medium. The efficiency of maintaining constant exposure condition was also evaluated using a simple two-compartment mass transport model employing a film-diffusion theory. An acute mortality test using 10 C. elegans in each well was conducted for the evaluation of the validity of passive dosing and the comparative evaluation of the passive dosing method and the conventional spiking method.
RESULTS
Free concentration in the assay medium reached 95% steady state value within 2.2 hours without test organisms, indicating that this passive dosing method is useful for an acute toxicity test in 24 hours. The measured concentration after the mortality test agreed well with the estimated values from partitioning between PDMS and the assay medium. However, the difference between the nominal and the free concentration became larger as the spiked concentration approached water solubility, indicating the instability of the conventional spiking with a co-solvent.
CONCLUSIONS
The results in this study support that passive dosing provides a stable exposure condition for an acute toxicity test. Thus, it is likely that more reliable toxicity assessment can be made for hydrophobic chemicals using passive dosing.

Keyword

Benzyl butyl phthalate; Bioavailability; Free concentration; Partition coefficient; Water solubility

MeSH Terms

Benzophenones
Biological Availability
Boronic Acids
Caenorhabditis
Caenorhabditis elegans
Dibutyl Phthalate
Dimethylpolysiloxanes
Phthalic Acids
Solubility
Toxicity Tests, Acute
Benzophenones
Boronic Acids
Dibutyl Phthalate
Dimethylpolysiloxanes
Phthalic Acids