Ann Lab Med.  2015 Mar;35(2):263-265. 10.3343/alm.2015.35.2.263.

Efficacy of the Measurement of 25-Hydroxyvitamin D2 and D3 Levels by Using PerkinElmer Liquid Chromatography-Tandem Mass Spectrometry Vitamin D Kit Compared With DiaSorin Radioimmunoassay Kit and Elecsys Vitamin D Total Assay

Affiliations
  • 1Department of Laboratory Medicine, Cheil General Hospital & Women's Healthcare Center, Catholic Kwandong University College of Medicine, Seoul, Korea. vivid.hee@gmail.com
  • 2Department of Family Medicine, Cheil General Hospital & Women's Healthcare Center, Catholic Kwandong University College of Medicine, Seoul, Korea.

Abstract

No abstract available.


MeSH Terms

25-Hydroxyvitamin D 2/*blood
Cholecalciferol/*blood
Chromatography, High Pressure Liquid
Humans
*Radioimmunoassay
Reagent Kits, Diagnostic
*Tandem Mass Spectrometry
25-Hydroxyvitamin D 2
Cholecalciferol
Reagent Kits, Diagnostic

Figure

  • Fig. 1 Comparison between immunometric assays and LC-MS/MS (PerkinElmer MS/MS Vitamin D kit) for 25-hydroxyvitamin D quantification: (A, B) Linear regression between LC-MS/MS and ECLIA (Elecsys Vitamin D total assay), and LC-MS/MS and RIA (DiaSorin RIA kit), respectively. (C, D) Bland-Altman plot between LC-MS/MS and ECLIA, and LC-MS/MS and RIA, respectively. Open circles represent samples containing relatively low concentrations of 25-hydroxyvitamin D2 (<1 ng/mL), and black circles represent samples containing relatively high concentrations of 25-hydroxyvitamin D2 (≥1 ng/mL).Abbreviations: ECLIA, electrochemiluminescence immunoassay; LC-MS/MS, liquid chromatography-tandem mass spectrometry.

  • Fig. 2 Distribution for 25-hydroxyvitamin D3 (25OHD3) (A) and 25-hydroxyvitamin D2 (25OHD2) (B). Results were obtained by analyzing serum samples provided by 50 volunteers.


Cited by  2 articles

Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities
Jun Hyung Lee, Jee-Hye Choi, Oh Joo Kweon, Ae Ja Park
J Bone Metab. 2015;22(3):107-112.    doi: 10.11005/jbm.2015.22.3.107.

Prevalence of Vitamin D Deficiency and Insufficiency in Korean Children and Adolescents and Associated Factors
Anna Lee, Se Hwi Kim, Chung Mo Nam, Young-Jin Kim, Soo-Ho Joo, Kyoung-Ryul Lee
Lab Med Online. 2016;6(2):70-78.    doi: 10.3343/lmo.2016.6.2.70.


Reference

1. Saenger AK, Laha TJ, Bremner DE, Sadrzadeh SM. Quantification of serum 25-hydroxyvitamin D2 and D3 using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin deficiency. Am J Clin Pathol. 2006; 125:914–920. PMID: 16690491.
2. Moon HW, Cho JH, Hur M, Song J, Oh GY, Park CM, et al. Comparison of four current 25-hydroxyvitamin D assays. Clin Biochem. 2012; 45:326–330. PMID: 22244986.
Article
3. Chen Y, Kinney L, Božović A, Smith H, Tarr H, Diamandis EP, et al. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays. Clin Biochem. 2012; 45:1485–1490. PMID: 22705028.
Article
Full Text Links
  • ALM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr