Nucl Med Mol Imaging.  2008 Aug;42(4):285-291.

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium

Affiliations
  • 1Department of Nuclear Medicine, Seoul national University College of Medicine, Seoul, Korea. dsl@plaza.snu.ac.kr
  • 2Department of Cardiovascular Surgery, Seoul national University College of Medicine, Seoul, Korea.

Abstract

PURPOSE: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and
METHODS
In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F=28:27) of low-likelihood for coronary artery disease were enrolled and (201)Tl rest / (99m)Tc-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. (201)Tl rest / (99m)Tc-MIBI stress / (201)Tl 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, Q(delay) (perfusion measurement), delta(delay) (Q(delay)-m) and Z(delay) ((Q(delay)-m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis.
RESULTS
Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was 51.8+/-6.5 and the highest segmental perfusion was 87.0+/-5.9, and they are 58.7+/-8.1 and 87.3+/-6.0, respectively in women. In the viability assessment, Q(delay) showed AUC of 0.633, while those for delta(delay) and Z(delay) were 0.735 and 0.716, respectively. The AUCs of delta(delay) and Z(delay) were significantly higher than that of Q(delay) (p=0.001 and 0.018, respectively). The diagnostic performance of delta(delay), which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7.
CONCLUSION
On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Keyword

myocardial perfusion SPECT; quantitative analysis; viability assessment; normal variation

MeSH Terms

Area Under Curve
Coronary Artery Bypass
Coronary Artery Disease
Female
Humans
Male
Myocardium
Perfusion
ROC Curve
Sensitivity and Specificity
Tomography, Emission-Computed, Single-Photon
Transplants
Full Text Links
  • NMMI
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr