1. Krieglstein G, Langham ME. Influence of body position on the intraocular pressure of normal and glaucomatous eyes. Ophthalmologica. 1975; 171:132–45.
Article
2. Kiuchi T, Motoyama Y, Oshika T. Relationship of progression of visual field damage to postural changes in intraocular pressure in patients with normaltension glaucoma. Ophthalmology. 2006; 113:2150–5.
Article
3. Gudmundson LE. The pneumatonograph and Perkins' tonometer. A clinical study of the reproducibility in glaucomatous eyes. Acta Ophthalmol (Copenh). 1984; 62:731–8.
Article
4. Nakakura S, Mori E, Yamamoto M. . Intradevice and Interdevice Agreement Between a Rebound Tonometer, Icare PRO, and the Tonopen XL and Kowa Hand-held Applanation Tonometer When Used in the Sitting and Supine Position. J Glaucoma. 2013 Oct 17; [Epub ahead of print].
Article
5. Fernandes P, Díaz-Rey JA, Queirós A. . Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt. 2005; 25:436–40.
6. Sahin A, Niyaz L, Yildirim N. Comparison of the rebound tonometer with the Goldmann applanation tonometer in glaucoma patients. Clin Experiment Ophthalmol. 2007; 35:335–9.
Article
7. Hessemer V, Rössler R, Jacobi KW. [Tono-pen, a new position-in-dependent tonometer. Comparison with the Goldmann tonometer by applanation measurement]. Klin Monbl Augenheilkd. 1988; 193:420–6.
8. Yücel AA, Stürmer J, Gloor B. [Comparison of tonometry with the Keeler air puff noncontact tonometer "Pulsair" and the Goldmann applanation tonometer]. Klin Monbl Augenheilkd. 1990; 197:329–34.
9. Gräf M, Wassill H, Dick B. [A new site-independent tonometer (ProTon) in comparison with the Goldmann applanation ton-ometer]. Klin Monbl Augenheilkd. 1995; 206:255–61.
10. Schweier C, Hanson JV, Funk J, Töteberg-Harms M. Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions. BMC Ophthalmol. 2013; 13:44.
Article
11. Jablonski KS, Rosentreter A, Gaki S. . Clinical use of a new po-sition-independent rebound tonometer. J Glaucoma. 2013; 22:763–7.
Article
12. Kontiola AI, Goldblum D, Mittag T, Danias J. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Exp Eye Res. 2001; 73:781–5.
Article
13. Davies LN, Bartlett H, Mallen EA, Wolffsohn JS. Clinical evaluation of rebound tonometer. Acta Ophthalmol Scand. 2006; 84:206–9.
Article
14. Prashar A, Guggenheim JA, Erichsen JT. . Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies. Exp Eye Res. 2007; 85:563–71.
Article
15. Schild AM, Rosentreter A, Hermann MM. . [Comparison of Rebound tonometry versus Perkins tonometry in the supine glaucoma patient]. Klin Monbl Augenheilkd. 2011; 228:125–9.
16. Takenaka J, Mochizuki H, Kunihara E. . Evaluation of rebound tonometer for measuring intraocular pressure at deviated angle and position. Curr Eye Res. 2011; 36:422–8.
Article
17. Takenaka J, Mochizuki H, Kunihara E. . Intraocular pressure measurement using rebound tonometer for deviated angles and positions in human eyes. Curr Eye Res. 2012; 37:109–14.
Article
18. Moreno-Montañés J, Gosende I, Caire J. . Comparation of the new rebound tonometer IOPen and the Goldmann tonometer, and their relationship to corneal properties. Eye (Lond). 2011; 25:50–6.
Article
19. Muttuvelu DV, Baggesen K, Ehlers N. Precision and accuracy of the ICare tonometer - Peripheral and central IOP measurements by rebound tonometry. Acta Ophthalmol. 2012; 90:322–6.
Article
20. Chui WS, Lam A, Chen D, Chiu R. The influence of corneal properties on rebound tonometry. Ophthalmology. 2008; 115:80–4.
Article
21. Beasley IG, Laughton DS, Coldrick BJ. . Does rebound tonometry probe misalignment modify intraocular pressure measurements in human eyes? J Ophthalmol. 2013; 2013:791084.
Article