J Korean Ophthalmol Soc.  2009 Dec;50(12):1853-1859. 10.3341/jkos.2009.50.12.1853.

Comparison of RNFL Thickness Measured by Two Different Kind of OCT in NTG Patients

Affiliations
  • 1Department of Ophthalmology, Ewha Womans University School of Medicine, The Institue of Ophthalmology and Optometry, Seoul, Korea. ckrey02@mm.ewha.ac.kr

Abstract

PURPOSE
To compare retinal nerve fiber layer (RNFL) thicknesses with two types of OCT in patients with normal tension glaucoma (NTG) and early NTG.
METHODS
We evaluated the RNFL thicknesses of 101 eyes in 101 patients using Fourier domain OCT and time domain OCT. We compared the measured RNFL thicknesses according to the subject groups and the type of OCT. We calculated the area under the receiver operating characteristic curve (AUROC) to determine the best parameters with which to make a diagnosis of NTG or early NTG.
RESULTS
The RNFL thicknesses measured by 3D OCT were greater than that measured by Stratus OCT for all of the groups. The RNFL thickness in each group was statistically significantly different in the superior quadrant, the inferior quadrant, and the 1 and 2 o'clock positions when using 3D OCT. It was statistically significantly different in the superior, temporal, and inferior quadrant, as well as the 1, 7, 8, 9, 10 and 11 o'clock positions when using Stratus OCT. The largest AUROC was found for the inferior quadrant thickness (0.773) using Stratus OCT and the 1 o'clock thickness (0.712) using 3D OCT when comparing normal patients and those with suspected NTG. The largest AUROC was found for the inferior quadrant thickness (0.888) using Stratus OCT and the superior quadrant thickness (0.802) using 3D OCT when comparing normal patients and those with early NTG. The AUROC was greater in the temporal and inferior quadrants and in the 6, 7, 8, 9 and 10 o'clock thicknesses using Stratus OCT compared to the 3D OCT in differentiating patients with suspected NTG from normal patients. The AUROC found using 3D OCT compared to the Stratus OCT was greater only in the 1 o'clock thickness (p<0.05). The AUROC differentiating patients with early NTG from normal patients was greater in the temporal, inferior, nasal quadrant, and in the 5, 6, 7, 8, 9, 10 and 11 o'clock positions using the Stratus OCT compared to the 3D OCT (p<0.05).
CONCLUSIONS
The RNFL thicknesses measured using 3D OCT were generally greater than those measured using Stratus OCT. The largest AUROCs for differentiating patients with suspected NTG and early NTG from normal patients were in the 1 o'clock position and the superior quadrant RNFL thickness using 3D OCT and the inferior quadrant RNFL thickness using Stratus OCT. The AUROCs using the 3D OCT parameters were less than those from the Stratus OCT when comparing normal patients and those with suspected or early NTG.

Keyword

Fourier domain; Normal tension glaucoma; Optical coherence tomography; Time domain

MeSH Terms

Eye
Humans
Low Tension Glaucoma
Nerve Fibers
Retinaldehyde
ROC Curve
Tomography, Optical Coherence
Retinaldehyde

Cited by  1 articles

A Comparison of Retinal Nerve Fiber Layer Thickness Measured Using Five Different Optical Coherence Tomography Devices
Youn Gon Lee, Young Hoon Hwang
J Korean Ophthalmol Soc. 2018;59(3):261-267.    doi: 10.3341/jkos.2018.59.3.261.


Reference

References

1. Quigley HA, Dunkelberger GR, Green WR. Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol. 1989; 107:453–64.
Article
2. Harwerth RS, Carter-Dawson L, Smith EL 3rd, et al. Neural losses correlated with visual losses in clinical perimetry. Invest Ophthalmol Vis Sci. 2004; 45:3152–60.
Article
3. Quigley HA, Dunkelberger GR, Green WR. Chronic human glaucoma causing selectively greater loss of larger optic nerve fibers. Ophthalmology. 1988; 95:357–63.
4. Odberg T, Riise D. Early diagnosis of glaucoma: the value of succe-ssive stereophotography of the optic disc. Arch Ophthalmol (Copenh). 1985; 63:257–63.
5. Melo GB, Libera RD, Barbosa AS, et al. Comparison of optic disk and retinal nerve fiber layer thickness in nonglaucomatous and glaucomatous patients with high myopia. Am J Ophthalmol. 2006; 142:858–60.
Article
6. Choplin NT, Schallhorn SC. The effect of excimer laser photorefractive keratectomy for myopia on nerve fiber layer thickness measurements as determined by scanning laser polarimetry. Ophthalmology. 1999; 106:1019–23.
7. Colen TP, Lemij HG. Motion artifacts in scanning laser polarimetry. Ophthalmology. 2002; 109:1568–72.
Article
8. Takahashi H, Goto T, Shoji T, et al. Diabetes-associated retinal nerve fiber damage evaluated with scanning laser polarimetry. Am J Ophthalmol. 2006; 142:88–94.
Article
9. Kremmer S, Garway-Heath DF, De Cilla S, et al. Influence of cataract surgery with implantation of different intraocular lenses on scanning laser tomography and polarimetry. Am J Ophthalmol. 2003; 136:1016–21.
Article
10. Parikh RS, Parikh S, Sekhar GC, et al. Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma. Opthal-molology. 2007; 114:2238–43.
Article
11. Nouri-Mahdavi K, Hoffman D, Tannenbaum DP, et al. Identifying early glaucoma with optical coherence tomography. Am J Ophthalmol. 2004; 137:228–35.
Article
12. Hong SM, Ahn HS, Ha SJ, et al. Early glaucoma detection using the Humphery matrix perimeter, GDx VCC, Stratus OCT, and retinal nerve fiber layer photography. Ophthalmology. 2007; 114:210–5.
13. Kan SM, Lee SB, Uhm KB. Diagnostic ability of stratus OCT using Korean normative database for ealry detection of normal-tension glaucoma. J Korean Ophthalmol soc. 2008; 49:798–810.
14. Song YM, Uhm KB. Discrimination between normal and ealry stage of galucomatous eyes using the stratus optical coherence tomography. J Korean Ophthalmol soc. 2007; 48:1675–85.
15. Schuman JS, Pedut-Kloizman T, Hertzmark E, et al. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology. 1996; 103:1889–98.
Article
16. DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988; 44:837–45.
Article
17. Kim TW, Park UC, Park KH, Kim DM. Ability of Stratus OCT to identify localized retinal nerve fiber layer defects in patients with normal standard automated perimetry results. Invest Ophthalmol Vis Sci. 2007; 48:1635–41.
Article
18. Menke MN, Dabov S, Sturm V. Features of age-related macular degeneration assessed with three-dimensional Fourier-domain optical coherence tomography. Br J Ophthalmol. 2008; 92:1492–7.
Article
19. Gupta P, Gupta V, Dogra MR, et al. Morphological changes in the retinal pigment epithelium on spectral-domain OCT in the unaffected eyes with idiopathic central serous chorioretinopathy. Int Ophthalmol 2009 Jan 30. Epub ahead of print.
Article
20. Leung CK, Cheung CY, Weinreb RN, et al. Comparison of macular thickness measurements between time domain and spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2008; 49:4893–7.
Article
21. Menke MN, Knecht P, Sturm V, et al. Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT. Invest Ophthalmol Vis Sci. 2008; 49:5386–91.
Article
22. Hood DC, Fortune B, Arthur SN, et al. Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma. 2008; 17:519–28.
Article
23. Bowd C, Zangwill LM, Berry CC, et al. Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual fuction. Invest Ophthalmol Vis Sci. 2001; 42:1993–2003.
24. Kanamori A, Nakamura M, Escano MF, et al. Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography. Am J Ophthalmol. 2003; 135:513–20.
Article
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr