J Korean Soc Plast Reconstr Surg.  2010 Jul;37(4):385-390.

Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery

Affiliations
  • 1Department of Plastic and Reconstructive Surgery, Kangnam Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea. sismdps@chollian.net
  • 2Department of Radiology, Kangnam Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea.

Abstract

PURPOSE
The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body.
METHODS
From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal(7), foreign body removal and corrective plastic surgery(4), and conservative treatment with antibiotics and steroid injection(2).
RESULTS
High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared.
CONCLUSION
Considering the usefulness of high-resolution ultrasonography in foreign body injection, high-resolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.

Keyword

Foreign body; Inflammation; High-resolution ultrasonography

MeSH Terms

Anti-Bacterial Agents
Collagen
Foreign Bodies
Humans
Inflammation
Paraffin
Polymethyl Methacrylate
Prognosis
Reoperation
Retrospective Studies
Silicones
Surgery, Plastic
Transducers
Anti-Bacterial Agents
Collagen
Paraffin
Polymethyl Methacrylate
Silicones
Full Text Links
  • JKSPRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr