Tuberc Respir Dis.  1997 Apr;44(2):329-337. 10.4046/trd.1997.44.2.329.

The Comparison of Work of Breathing Between Before Extubation and After Extubation of Endotracheal Tube

Abstract

BACKGROUND: Since endotracheal tube is the most important factor involved in the imposed work of breathing during mechanical ventilation, extubation of endotracheal tube is supposed to reduce respiratory work of patient. However, some patients show labored breathing after extubation despite acceptable blood gases. We investigated the changes of work of breathing before and after extubation and the factors involved in the change of WOB after extubation.
METHODS
The subjects were 34 patients(M : F = 20 : 14, mean age = 61 l7yre) who recovered from respiratory failure after ventilatory support and were considered to be ready for extubation. The patients with clinical or radiologic evidences of upper airway obstruction before endotracheal intubation for mechanical ventilation were excluded. Vital sign, physical examination, chest X-ray, work of breathing and other respiratory mechanic indices were measured prior to, immediately, 6, 24 and 48 hours after extubation serially. Definition of weaning failure after extubation was resumption of ventilatory support or reintubation of endotracheal tube within 48 hour after extubation because of respiratory failure. The patients were classified into group I (decreased work of breathing), group 2(unchanged work of breathing) and group 3(increased work of breathing) depending on the statistical difference in the change of work of breathing before and after extubation.
RESULTS
Work of breathing decreased in 33%(11/34, group 1), unchanged in 41%(14/34, group 2) and increased in 26% (9/34, group 3) of patients after extubation compared with before extubation. Weaning failure occurred 9%(1/11) of group, 1, 28.67(4/14) of group 2 and 44.4%(4/9) of group 3 after extubation(p = 0.07). The change of work of breathing after extubation was positively correlated with change of mean airway resistance(mRaw). (r = 0.794, p> 0.01) In three cases of group 3 whose respiratory indices could be measured until 48 hr ater extubation, the change in work of breathing paralleled with the sequential change of mRaw. The work of breathing was peaked at 6 hr after extubation, which showed a tendency to decrease thereafter.
CONCLUSIONS
Reversible increase of work of breathing after extubation may occur in the patients who underwent extubation, and the increase in mRaw could be responsible for the increase in work of breathing. In addition, the risk of weaning failure after extubatuion may increase in the patients who have increased WOB immediately after extubation.

Keyword

Work of breathing; Extubation; Mechanical ventilation

MeSH Terms

Airway Obstruction
Gases
Humans
Intubation, Intratracheal
Physical Examination
Respiration
Respiration, Artificial
Respiratory Insufficiency
Respiratory Mechanics
Thorax
Vital Signs
Weaning
Work of Breathing*
Gases
Full Text Links
  • TRD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr