Anesth Pain Med.  2007 Oct;2(4):252-256.

Comparison of the Success Rates of Lightwand Tracheal Intubation on the First Attempt When Using the Lightwand at Different Angles

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Fatima Hospital, Daegu, Korea. lovehan3@yahoo.co.kr

Abstract

BACKGROUND: It has been recommended that lightwand tracheal intubation be used for cases in which there is difficult airway management. Transillumination of the soft tissue of the neck by the lightwand can lead to successful intubation; however, this depends on skin color, obesity, head position, angle and the bent length of the lightwand. The goal of this study was to compare the success rates of intubation on the first attempt and complications of lightwand orotracheal intubation that occurred when using the lightwand at angles of 60 degrees and 90 degrees.
METHODS
One hundred forty eight patients of ASA physical status 1 or 2 were enrolled in this study. Patients in whom intubation had previously been difficult as well as patients who had the potential for difficult intubation were excluded from this study. Patients were randomly assigned to one of two groups: The lightwand bent in 60 degrees (LW60) group and the lightwand bent in 90degrees (LW90) group. Anesthesia was performed using propofol (2 mg/kg), fentanyl (1microg/kg) and rocuronium (0.9 mg/kg), and lightwand orotracheal intubation was attempted 2 minutes after the induction of anesthesia. The success rates of intubation, the number of attempts and their duration, as well as hemodynamic changes, resistance to the tube and complications that occurred during the procedure were recorded.
RESULTS
In the LW90 group, resistance to the tube during lightwand intubation occurred in a significant number of patients (P < 0.05), however, there were no significant differences observed between the two groups with regard to the intubation success rates on the first attempt, the duration of intubation, hemodynamic changes and complications.
CONCLUSIONS
Their were no significant differences observed between intubation success rates on first attempt and complications when using a lightwand bent to 60 degrees or 90 degrees in patients without any previously known airway abnormalities.

Keyword

angle of lightwand; tracheal intubation; transillumination

MeSH Terms

Airway Management
Anesthesia
Fentanyl
Head
Hemodynamics
Humans
Intubation*
Neck
Obesity
Propofol
Skin
Transillumination
Fentanyl
Propofol
Full Text Links
  • APM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr