Clin Orthop Surg.  2014 Sep;6(3):267-272. 10.4055/cios.2014.6.3.267.

Examination of the Pronator Quadratus Muscle during Hardware Removal Procedures after Volar Plating for Distal Radius Fractures

Affiliations
  • 1Department of Orthopedic Surgery, Soonchunhyang University College of Medicine, Cheonan, Korea.
  • 2Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea. hsgong@snu.ac.kr

Abstract

BACKGROUND
It is not clear whether the pronator quadratus (PQ) muscle actually heals and provides a meaningful pronation force after volar plating for distal radius fractures (DRFs). We aimed to determine whether the length of the PQ muscle, which is dissected and then repaired during volar plating for a DRF, affects the forearm rotation strength and clinical outcomes.
METHODS
We examined 41 patients who requested hardware removal after volar plating. We measured the isokinetic forearm rotation strength and clinical outcomes including grip strength, wrist range of motion, and disabilities of the arm, shoulder and hand (DASH) scores at 6 months after fracture fixation. During the hardware removal surgery, which was performed at an average of 9 months (range, 8.3 to 11.5 months) after fracture fixation, we measured the PQ muscle length.
RESULTS
The average PQ muscle length was 68% of the normal muscle length, and no significant relationship was found between the PQ muscle length and the outcomes including isokinetic forearm rotation strength, grip strength, wrist range of motion, and DASH scores.
CONCLUSIONS
This study demonstrates that the length of the healed PQ muscle does not affect isokinetic forearm rotation strength and clinical outcomes after volar plating for DRFs. The results of this study support our current practice of loose repair of the PQ that is performed by most of the surgeons to prevent tendon irritation over the plate, and suggest that tight repair of the PQ is not necessary for achieving improved forearm function.

Keyword

Distal radius fracture; Volar plating; Pronator quadratus; Isokinetic strength

MeSH Terms

Adult
Aged
Bone Plates
Device Removal
Female
Forearm/physiopathology/surgery
Fracture Fixation, Internal/*methods
Hand Strength
Humans
Male
Middle Aged
Muscle Strength
Muscle, Skeletal/physiopathology/*surgery
Radius Fractures/radiography/*surgery
Range of Motion, Articular
Wound Healing
Young Adult

Figure

  • Fig. 1 Intraoperative photograph of the pronator quadratus (PQ) muscle covering the volar plate. The length of the healed PQ muscle was measured using a ruler at 2 cm proximal to the distal radioulnar joint between the lateral border of the ulna and the lateral margin of the muscular part along the direction of its fibers (B). For the reference length of the PQ muscle, we measured the length between the lateral border of the ulna and the lateral border of the radius (A). The relative length of the PQ muscle was calculated as B/A (%).


Reference

1. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM. Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am. 2006; 88(12):2687–2694.
2. Lozano-Calderon SA, Doornberg JN, Ring D. Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures. Hand (N Y). 2008; 3(2):102–110.
3. Protopsaltis TS, Ruch DS. Volar approach to distal radius fractures. J Hand Surg Am. 2008; 33(6):958–965.
4. Huh JK, Lim JY, Song CH, Baek GH, Lee YH, Gong HS. Isokinetic evaluation of pronation after volar plating of a distal radius fracture. Injury. 2012; 43(2):200–204.
5. Dos Remedios C, Nebout J, Benlarbi H, Caremier E, Sam-Wing JF, Beya R. Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis: surgical technique. Chir Main. 2009; 28(4):224–229.
6. Heidari N, Clement H, Kosuge D, Grechenig W, Tesch NP, Weinberg AM. Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? J Hand Surg Eur Vol. 2012; 37(5):402–406.
7. Fallahi F, Jafari H, Jefferson G, Jennings P, Read R. Explorative study of the sensitivity and specificity of the pronator quadratus fat pad sign as a predictor of subtle wrist fractures. Skeletal Radiol. 2013; 42(2):249–253.
8. Chloros GD, Papadonikolakis A, Ginn S, Wiesler ER. Pronator quadratus space and compartment syndrome after low-energy fracture of the distal radius: a case report. J Surg Orthop Adv. 2008; 17(2):102–106.
9. Swigart CR, Badon MA, Bruegel VL, Dodds SD. Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. J Hand Surg Am. 2012; 37(9):1868–1873.
10. McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T. Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am. 2009; 34(9):1612–1617.
11. Stuart PR. Pronator quadratus revisited. J Hand Surg Br. 1996; 21(6):714–722.
12. Armangil M, Bezirgan U, Basarir K, Bilen G, Demirtas M, Bilgin SS. The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eur J Orthop Surg Traumatol. 2014; 24(3):335–339.
13. Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA. The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma. 2013; 27(3):130–133.
14. Tosti R, Ilyas AM. Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures. J Hand Surg Am. 2013; 38(9):1678–1684.
15. Gallagher MA, Cuomo F, Polonsky L, Berliner K, Zuckerman JD. Effects of age, testing speed, and arm dominance on isokinetic strength of the elbow. J Shoulder Elbow Surg. 1997; 6(4):340–346.
16. Drouin JM, Valovich-mcLeod TC, Shultz SJ, Gansneder BM, Perrin DH. Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements. Eur J Appl Physiol. 2004; 91(1):22–29.
17. Oh JH, Yoon JP, Kim JY, Oh CH. Isokinetic muscle performance test can predict the status of rotator cuff muscle. Clin Orthop Relat Res. 2010; 468(6):1506–1513.
18. Gunther CM, Burger A, Rickert M, Crispin A, Schulz CU. Grip strength in healthy caucasian adults: reference values. J Hand Surg Am. 2008; 33(4):558–565.
19. Hudak PL, Amadio PC, Bombardier C. The Upper Extremity Collaborative Group (UECG). Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). Am J Ind Med. 1996; 29(6):602–608.
20. Graff S, Jupiter J. Fracture of the distal radius: classification of treatment and indications for external fixation. Injury. 1994; 25:Suppl 4. S-D14–S-D25.
21. Matsuoka J, Berger RA, Berglund LJ, An KN. An analysis of symmetry of torque strength of the forearm under resisted forearm rotation in normal subjects. J Hand Surg Am. 2006; 31(5):801–805.
22. Gordon KD, Dunning CE, Johnson JA, King GJ. Influence of the pronator quadratus and supinator muscle load on DRUJ stability. J Hand Surg Am. 2003; 28(6):943–950.
23. Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008; 12(1):2–6.
24. Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am. 2008; 33(2):164–167.
25. Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg. 2009; 17(6):369–377.
Full Text Links
  • CIOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr