Difficulty in Removal of a Femoral Intramedullary Nail: The Geometry of the Distal End of the Nail

Bombaci H, Gorgec M

Different difficulties can be encountered during removal of an intramedullary femoral nail depending partly upon the design of the nail but mainly on bone ingrowth. This possibility is higher in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
New Technique for Removal of the Ulnar Intramedullary Nail Failed to Remove: Broken Assembly Piece in the Nail

Yi JW, Oh BH, Kim SB, Heo YM, Kim TG, Kim DH, Jung YS

Methods about removal of intramedullary nail in complicated cases were reported in some literatures but there are no reports about nail removal in the ulna. The authors would like to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Chin Deformity after Removal of Silicone Chin Implant: A Case Report

Lee SY

  • KMID: 2117738
  • J Korean Soc Aesthetic Plast Surg.
  • 2010 Feb;16(1):53-56.
Chin augmentation with silicone implants has long been considered as a simple and effective operation to increase chin projection. However, insertion and subsequent removal of silicone chin implant are not...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Delayed Left Atrial Perforation Associated with Erosion After Device Closure of an Atrial Septal Defect

Kim JS, Yeom SY, Kim SH, Choi JW, Kim KH

A 43-year-old man who had had a history of atrial septal defect (ASD) device closure 31 months previously presented with abrupt chest and back pain along with progressive cardiogenic shock...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Application of Lateral Approach for the Removal of Migrated Interbody Cage: Taphole and Fixing Technique

Eom JS, Jeon I, Kim SW

When a revision surgery related with removal of failed interbody cage is required, going through the previous passage can lead to a higher risk of neurological deficits or incidental dural...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Percutaneous Removal of Cutted Left Atrial Pressure Catheter after Mitral Valve Replacement

Jung HS, Kim JY, Ahn MS, Lee KH, Kim WJ, Yoo BS, Lee SH, Yoon JH, Choe KH

We experienced a case of the successful retlement of a remnant cutted left atrial pressure catheter found in the left ventricle and ascending aorta on the 67 th day after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Successful Retrieval of a Fractured Guidewire during Extracorporeal Membrane Oxygenator Insertion

Moon JH, Kim HK, Moon SM, Park JE, Byeon SG, Park TK, Yang JH

Recently, the use of extracorporeal membrane oxygenation has evolved rapidly and there is potential for expanding its use. There are many complications associated with extracorporeal membrane oxygenation, but the fracture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Remnant Pacemaker Lead Tips after Lead Extractions in Pacemaker Infections

Kim D, Baek YS, Lee M, Uhm JS, Pak HN, Lee MH, Joung B

Complete hardware removal is recommended in the case of patients with cardiovascular implantable electronic device (CIED) infections. However, the complete extraction of chronically implanted leads is not always achieved. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Retrieval of Embolized Amplatzer Septal Occluder after Treatment of Double Atrial Septal Defect: A Case Report

Cho JY, Kim KH, Yoon HJ, Seon HJ, Ahn Y, Jeong MH, Cho JG, Park JC

Embolization of the occlusion device after percutaneous closure of atrial septal defect (ASD) is a potential disastrous complication. The usual site of embolization is the right side of the heart...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Air Embolism in the Left Ventricle after the Removal of a Central Venous Catheter

Cho DS, Kim MH, Lee DH, Lee HW, Kim EB, Kim SH, Jung HJ, Kim SJ, Kim HJ

Air embolism is a rare, potentially critical complication that can induce death. Central venous catheterization, which is commonly used for critically ill patients, is a possible cause of air embolism....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Retrieval of an Embolized Central Venous Chemoport in a Patient With Colon Cancer

Kim JE, Kim MK, Shim YK, Kim JT, Kim SM, Lee SY, Bae JW, Hwang KK, Kim DW, Cho MC

The central access device is commonly used as a route of chemotherapuetic agents in patients with malignant diseases for its convenient and safety for insertion. This report describes a case...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Pedicle Screw Fixation in Thoracolumbar Fractures: Comparison of Results According to Implant Removal Time

Oh HS, Seo HY

BACKGROUND: The purpose of this study was to determine whether restoration of range of motion (ROM) could be achieved by implant removal after natural bone healing and consolidation of fractured...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Removal of Visualized Nasal Foreign Bodies with a Clip

Jang PM, Cho YS, Kim HJ

  • KMID: 2192784
  • J Korean Soc Emerg Med.
  • 2009 Feb;20(1):130-133.
PURPOSE: Nasal foreign bodies in children are often encountered in emergency medicine and treated using many methods. This study was conducted to describe the benefit of a clip used in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Impact on Retrievability by Cement Variety for Implant Restorations Equipped with a Lingual Slot

Lee JH, Lee KB

PURPOSE: The purpose of this study is to measure and compare the removal torques of different cements applied in attachments of zirconia restorations on titanium (Ti) abutments fitted with retrievable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique

Park JS, Pak HN, Lee MH, Kim SS, Joung B

A 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous retrieval of a misplaced transjugular intrahepatic portosystemic shunt stent using the rigid endobronchial forceps

Vu J, Kim SK

Summary of Event: A transjugular intrahepatic portosystemic shunt (TIPS) stent (Viatorr) was misplaced into main portal vein and superior mesenteric vein. This misplaced covered stent was then successfully retrieved using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique

Park JS, Pak HN, Lee MH, Kim SS, Joung B

A 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Breakage of a Lag Screw of Cephalomedullary Nail: A Technique of Removal

Tantigate , Riansuwan , Mahaisavariya B, Sukjaitham K

A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Risk Factors of Catheter Loss Following Peritonitis in Patients on Continuous Ambulatory Peritoneal Dialysis

Jang M, Hwang E, Kim J, Choi G, Han S, Park S, Hong Y, Lee K, Kim H

  • KMID: 1855497
  • Korean J Nephrol.
  • 2010 May;29(3):357-365.
PURPOSE: Peritoneal dialysis (PD) catheter removal is regarded as an important index of patient morbidity. The aim of this study was to evaluate factors influencing catheter loss following peritonitis in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound

Kim S, Choi YS, Kim JS, Kim S, Cho S

OBJECTIVE: The aim of this study was to present experiences in localization and removal of non-palpable subdermal contraceptive implants with ultrasonography. METHODS: Medical records from January 1, 2016, to April 30,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close