Electro-Mechanical Safety Testing of Portable ECG Devices for Home Healthcare Usage

Kim JH, Cho EJ, Lee CK, Park SK, Lee BC, Yoo SK

OBJECTIVES: This paper suggests the experimental guidelines to evaluate the electro-mechanical safety of belt type equipment. The electro-mechanical safety was determined by using the International Electrotechnical Commission guidelines, which are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Medical device adverse effects

Kwon BS

This study aimed to describe adverse effects or reactions by medical devices. There may be unexpected effects caused by medical devices that can often be harmful to the patient. This...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Review of regulatory management on standards and specifications for veterinary medical devices in Korea

Kang KM, Kim TW, Kwon OR, Park HJ, Cho SM, Kim CH, Lee MH, Moon JS

Well-established standards and specifications for medical devices not only provide clarity and consistency in licensing processes but also secure device safety and effectiveness. This study reviewed regulatory standards and specifications...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects and Satisfaction of Medical Device Safety Information Reporting System Using Electronic Medical Record

Jang HJ, Choi YD, Kim NH

OBJECTIVES: This paper describes an evaluation study on the effectiveness of developing an in-hospital medical device safety information reporting system for managing safety information, including adverse incident data related to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Arrangements of the intravenous parallel infusions with anti-reflux valves decreasing occlusion alarm delay

Joe HB, Moon BK, Lee YJ, Min SK

BACKGROUND: The methods of arrangement of combined intravenous parallel infusions using anti-reflux valve (ARV), with and without anti-syphon valve (ASV) that could decrease occlusion alarm delay were investigated. METHODS: Occlusion challenge...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An evaluation of the Manufacturer And User Facility Device Experience database that inspired the United States Food and Drug Administration's Reclassification of transvaginal mesh

Sandberg J, Gray I, Pearlman A, Terlecki R

PURPOSE: To assess the utility of the Manufacturer And User Facility Device Experience (MAUDE) database in objectively capturing adverse events for transvaginal mesh in the United States. MATERIALS AND METHODS: We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Incidence of Riata Defibrillator Lead Failure: a Single-Center Experience

Gwag HB, Hwang JK, Park KM, Park SJ, On YK, Kim JS

Riata defibrillator leads were recalled due to a high failure rate. This study measured the incidence of externalized conductor (EC) and electrical dysfunction (ED) and sought to determine the predictors...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative clinical study on the accuracy and efficacy of Accumate(R) 1100, an infusion pump for patient-controlled analgesia

Kim KM, Noh GJ

BACKGROUND: The accuracy and efficacy of patient-controlled analgesia (PCA) devices are crucial because malfunction of the devices may lead to fatal outcomes. The aim of this study is to evaluate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of Factors Affecting the Usefulness and Diagnostic Yield of Core Biopsy Needles with a Side Hole in Endoscopic Ultrasound-Guided Fine-Needle Aspiration

Inoue T, Okumura F, Mizushima , Nishie H, Iwasaki H, Anbe K, Ozeki T, Kachi K, Fukusada S, Suzuki Y, Sano H

BACKGROUND/AIMS: A barbed puncture needle with a side hole was recently developed to improve sample quality and quantity in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). In this study, we retrospectively assessed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cardiac Implantable Electronic Device Safety during Magnetic Resonance Imaging

Hwang YM, Kim J, Lee JH, Kim M, Nam GB, Choi KJ, Kim YH

BACKGROUND AND OBJECTIVES: Although magnetic resonance imaging (MRI) conditional cardiac implantable electronic devices (CIEDs) have become recently available, non-MRI conditional devices and the presence of epicardial and abandoned leads remain...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Prospective, Randomized, Controlled Comparative Study of Three Energy Devices in Open Thyroid Surgery: Thunderbeat, Harmonic, and Ligasure

Back K, Hur N, Kim MJ, Choe JH, Kim JH, Kim JS

PURPOSE: Energy devices, such as Harmonic Focus Plus (Ethicon; ultrasonic scalpel; Harmonic) and Ligasure Small Jaw (Covidien; bipolar sealer; Ligasure) are widely used in thyroid surgery as substitutes for Bovie...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy

Kim JH, Hong SS, Kim JH, Park HJ, Chang YW, Chang AR, Kwon SB

OBJECTIVE: To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. MATERIALS AND METHODS: We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement

Song HY, Nam DH, Lee H

OBJECTIVE: To investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. MATERIALS AND METHODS: Between June 2007 and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
National Endoscopy Quality Improvement Program Remains Suboptimal in Korea

Cha JM, Moon JS, Chung IK, Kim JO, Im JP, Cho YK, Kim HG, Lee SK, Lee HL, Jang JY, Kim ES, Jung Y, Moon CM, Kim Y, Park BY

BACKGROUND/AIMS: We evaluated the characteristics of the National Cancer Screening Program (NCSP) and opinions regarding the National Endoscopy Quality Improvement Program (NEQIP). METHODS: We surveyed physicians performing esophagogastroduodenoscopy and/or colonoscopy screenings...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top