Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

72 results
Display

Shape memory alloy actuation of non-bonded piezo sensor configuration for bone diagnosis and impedance based analysis

Srivastava S, Bhalla S, Madan A

In the recent years, there has been a growing interest in research community towards the application of smart materials for bio-medical structural health monitoring. Amongst the smart materials, directly bonded...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Role of Esophageal Mean Nocturnal Baseline Impedance and Post-reflux Swallow-induced Peristaltic Wave Index in Discriminating Chinese Patients With Heartburn

Sun YM, Gao Y, Gao F

  • KMID: 2460480
  • J Neurogastroenterol Motil.
  • 2019 Oct;25(4):515-520.
  • doi: 10.5056/jnm19056
BACKGROUND/AIMS: Recently, esophageal mean nocturnal baseline impedance (MNBI) and post-reflux swallow-induced peristaltic wave (PSPW) index have been proposed, which can increase the diagnostic role of multichannel intraluminal impedance and pH...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Letter to the Editor: Normal Reference Plots of the Bioelectrical Impedance Vector for Healthy Korean Adults

Lukaski HC

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bioelectrical Impedance Analysis for Prediction of Early Complications after Gastrectomy in Elderly Patients with Gastric Cancer: the Phase Angle Measured Using Bioelectrical Impedance Analysis

Yu B, Park KB, Park JY, Lee SS, Kwon OK, Chung HY

PURPOSE: Phase angle obtained using bioelectrical impedance analysis (BIA) provides a relatively precise assessment of the nutritional status of elderly patients. This study aimed to evaluate the significance of phase...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Normal Reference Plots for the Bioelectrical Impedance Vector in Healthy Korean Adults

Oh JH, Song S, Rhee H, Lee SH, Kim DY, Choe JC, Ahn J, Park JS, Shin MJ, Jeon YK, Lee HW, Choi JH, Lee HC, Cha KS

BACKGROUND: Accurate volume measurement is important in the management of patients with congestive heart failure or renal insufficiency. A bioimpedance analyser can estimate total body water in litres and has...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor

Kim GE, Kim SY, Kim SJ, Yun SY, Jung HH, Kang YS, Koo BN

PURPOSE: The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Association between body composition measured by bioelectrical impedance analysis and platelet-to-lymphocyte ratio in colorectal cancer

Song WJ, Kim KE, Bae SU, Jeong WK, Baek SK

PURPOSE: This study investigated the relationship between body composition and platelet-to-lymphocyte ratio (PLR) in patients with colorectal cancer (CRC). METHODS: This retrospective study included 110 patients who underwent anthropometric measurement by...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Association between bioelectrical impedance analysis and platelet-to-lymphocyte ratio in colorectal cancer

Kim JS

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Combined Multichannel Intraluminal Impedance and High-resolution Manometry Improves Detection of Clinically Relevant Esophagogastric Junction Outflow Obstruction

Song BG, Min YW, Lee H, Min BH, Lee JH, Rhee PL, Kim JJ

  • KMID: 2433500
  • J Neurogastroenterol Motil.
  • 2019 Jan;25(1):75-81.
  • doi: 10.5056/jnm18148
BACKGROUND/AIMS: Esophagogastric junction outflow obstruction (EGJOO) is a diagnostically heterogeneous group with variable clinical relevance. We studied whether evaluation of bolus transit by multichannel intraluminal impedance (MII) is useful for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relative Association of Overhydration and Muscle Wasting with Mortality in Hemodialysis Patients: Assessment by Bioelectrical Impedance Analysis

Kim E, Seo SO, Choi YB, Lee MJ, Lee JE, Kim HJ

BACKGROUND/AIMS: Assessment of fluid status in hemodialysis patents is very important. Overhydration in hemodialysis is associated with generalized edema, cardiovascular complications, and hypertension. The aim of this study was to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Use of Bioelectrical Impedance Analysis for the Measurement of Appendicular Skeletal Muscle Mass/Whole Fat Mass and Its Relevance in Assessing Osteoporosis among Patients with Low Back Pain: A Comparative Analysis Using Dual X-ray Absorptiometry

Fujimoto K, Inage K, Eguchi Y, Orita S, Suzuki M, Kubota G, Sainoh T, Sato J, Shiga Y, Abe K, Kanamoto H, Inoue M, Kinoshita , Norimoto M, Umimura T, Koda M, Furuya T, Akazawa T, Toyoguchi , Terakado A, Takahashi , Ohtori S

STUDY DESIGN: Cross-sectional observational study. PURPOSE: To compare measurements of appendicular skeletal muscle mass (ASMM) and whole fat mass (WFM) obtained using dualenergy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

Wong U, Person EB, Castell DO, von Rosenvinge E, Raufman JP, Xie G

  • KMID: 2422847
  • J Neurogastroenterol Motil.
  • 2018 Oct;24(4):570-576.
  • doi: 10.5056/jnm18010
BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Rumination Syndrome: Unknown Pathology Easy to Diagnose With High-resolution Impedance Manometry

Vizcaino E, Rodriguez-Valcárcel FC, de Los Ríos CC

  • KMID: 2417396
  • J Neurogastroenterol Motil.
  • 2018 Jul;24(3):503-505.
  • doi: 10.5056/jnm18048
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship between Body Composition and Cognitive Function : Using Bioelectrical Impedance Analysis

Roh J, Kim H, Lee KJ

OBJECTIVE: Body composition is measured using bioelectrical impedance analysis (BIA), and correlation between the result of BIA and cognitive function is analyzed. METHODS: A total of 118 elderly (46 male, 72...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
What Is the Future of Impedance Planimetry in Gastroenterology?

Gregersen , Lo KM

  • KMID: 2413094
  • J Neurogastroenterol Motil.
  • 2018 Apr;24(2):166-181.
  • doi: 10.5056/jnm18013
The gastrointestinal (GI) tract is efficient in transporting ingested material to the site of delivery in healthy subjects. A fine balance exists between peristaltic forces, the mixing and delivery of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Esophageal Baseline Impedance Reflects Mucosal Integrity and Predicts Symptomatic Outcome With Proton Pump Inhibitor Treatment

Xie C, Sifrim D, Li Y, Chen M, Xiao Y

  • KMID: 2417271
  • J Neurogastroenterol Motil.
  • 2018 Jan;24(1):43-50.
  • doi: 10.5056/jnm17032
BACKGROUND/AIMS: Esophageal baseline impedance, which is decreased in gastroesophageal reflux disease (GERD) patients, is related to the severity of acid reflux and the integrity of the esophageal mucosa. The study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Can Esophageal Baseline Impedance Predict Proton Pump Inhibitor Response in Gastroesophageal Reflux Disease?

Jung K, Park MI

  • KMID: 2417266
  • J Neurogastroenterol Motil.
  • 2018 Jan;24(1):1-3.
  • doi: 10.5056/jnm17138
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utility of Volume Assessment Using Bioelectrical Impedance Analysis in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Prospective Observational Study

Park KH, Shin JH, Hwang JH, Kim SH

BACKGROUND: Fluid overload prior to continuous renal replacement therapy (CRRT) is an important prognostic factor. Thus, precise evaluation of fluid status is necessary to treat such patients. In this study,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Belching in Irritable Bowel Syndrome: An Impedance Study

Obekli T, Akyuz F, Akyuz U, Arici S, Ä°liaz R, Gokturk S, Evirgen S, Cavus B, Karaca C, Demir K, Besisik F, Kaymakoglu S

  • KMID: 2387832
  • J Neurogastroenterol Motil.
  • 2017 Jul;23(3):409-414.
  • doi: 10.5056/jnm16103
BACKGROUND/AIMS: There are limited data about the relation between belching and irritable bowel syndrome (IBS). We aim to evaluate belching in patients with IBS. METHODS: Twenty-five patients with IBS and 12...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Relationship of the Post-reflux Swallow-induced Peristaltic Wave Index and Esophageal Baseline Impedance with Gastroesophageal Reflux Disease Symptoms

Cho YK, Lee JS, Lee TH, Hong SJ, Park SJ, Jeon SR, Kim HG, Kim JO

  • KMID: 2433524
  • J Neurogastroenterol Motil.
  • 2017 Apr;23(2):237-244.
  • doi: 10.5056/jnm16115
BACKGROUND/AIMS: The post-reflux swallow-induced peristaltic wave (PSPW) index and esophageal baseline impedance (BI) are novel impedance parameters used to evaluate esophageal chemical clearance and mucosal integrity. However, their relationship with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2022 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr