Display

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

Nirale RM, Thombre R, Kubasad G

PURPOSE: To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS: A brass die was prepared by...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three dimensional deformation of dry-stored complete denture base at room temperature

Lim SR, Lee JS

PURPOSE: The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study on the accuracies of resin denture bases and metal denture bases

Park HW, Kim CW, Kim YS

  • KMID: 2195895
  • J Korean Acad Prosthodont.
  • 2001 Jun;39(3):250-259.
Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative tensile bond strength of heat-cured, cold-cured, and light cured denture base resins bonded to continuous: pressure injection type denture base resin

Whang SW, Chung MK

  • KMID: 1696408
  • J Korean Acad Prosthodont.
  • 1993 Sep;31(3):385-393.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An in vitro study on cellular response of several denture base resins

Jun CO, Vang MS

  • KMID: 1959717
  • J Korean Acad Prosthodont.
  • 1992 Aug;30(2):347-357.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

Al-Fouzan , Al-mejrad , Albarrag A

PURPOSE: The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS: Twenty discs of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The bond strength of rebase resin to denture base resin

Kim IP, Cho HW, Jin TH

  • KMID: 1696597
  • J Korean Acad Prosthodont.
  • 1993 Dec;31(4):515-522.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The color change of denture base resins by coffee

Han SH, Dong JK, Jin TH

  • KMID: 1696599
  • J Korean Acad Prosthodont.
  • 1993 Dec;31(4):523-531.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC

Lee SH, Chang IT, Yim SH

  • KMID: 1907068
  • J Korean Acad Prosthodont.
  • 1999 Apr;37(2):167-184.
The purpose of this study was to evaluate and compare the fit of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A clinical study on the retention of maxillary complete denture with different denture base materials

Lee JH, Lim JH, Cho IH

  • KMID: 2195907
  • J Korean Acad Prosthodont.
  • 2001 Feb;39(1):58-70.
For the successful treatment of complete denture, obtaining a good retention is essential. There are lots of factors affecting denture retention. Denture material, one of those factors affecting denture retention,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE

Lee HY

  • KMID: 2195350
  • J Korean Acad Prosthodont.
  • 1998 Feb;36(1):18-25.
The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study on the dimensional change of the different denture bases

Kim MJ, Kim CW

  • KMID: 2000651
  • J Korean Acad Prosthodont.
  • 2006 Dec;44(6):712-721.
STATEMENT OF PROBLEM: Acrylic resin is most commonly used for denture bases. However, acrylic resin has week points of volumetric shrinkage during polymerization that reduces denture fit. The expandability of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A case of allergic contact stomatitis due to denture relining materials

Kim KH, Joh GY, Kim YS

  • KMID: 2128363
  • Korean J Dermatol.
  • 1992 Dec;30(6):892-896.
Many sensitizing chemicals and additives are used in manifacturing and mending dentures. Among them, phtolyldiethanolamine, a kind of accelerto for polymerization, is necessary only in self-curing acrylic resins which are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

Lee S, Hong SJ, Paek J, Pae A, Kwon KR, Noh K

PURPOSE: The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS: The maxillary edentulous master cast was fabricated and round shaped...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Complete denture rehabilitation of fully edentulous patient with severe bone resorption and class II jaw relation using piezography

Kwon W, Song YG, Lee JS

Piezography, prosthetic space recorded by pronunciation, can be used as a reference for arrangement of artificial teeth and polishing surface of a denture. In this case, a 67 year old...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Complete denture fabricated by Jiro Abe's method for edentulous patient with severe alveolar ridge resorption: a case report

Jun D, Yang DH, Vang M, Yang H, Park S, Yun K

Fabrication of complete denture by Jiro Abe's method was introduced that enhance the retention and stability of denture by sealing around the denture border with mucous membrane to make negative...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tensile bond strength of four denture resins to porcelain teeth with different surface treatment

El-Sheikh , Powers J

PURPOSE: This study evaluated the bond strength between porcelain denture teeth (Bioblend 43D) and four different polymerized denture resins (Lucitone 199, Palapress, Acron MC, Triad) with and without a bonding...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Investigation of bonding properties of denture bases to silicone-based soft denture liner immersed in isobutyl methacrylate and 2-hydroxyethyl methacrylate

Akin H, Tugut F, Mutaf B, Guney U

PURPOSE: The purpose of this study was to investigate the bonding properties of denture bases to silicone-based soft denture liners immersed in isobutyl methacrylate (iBMA) and 2-hydroxyethyl methacrylate (HEMA) for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of denture adhesives on the retention of complete denture

Yoon YM, Choi YS, Lee JS

  • KMID: 2321769
  • J Korean Acad Prosthodont.
  • 2010 Apr;48(2):87-93.
PURPOSE: The purpose of this study was to compare the retention of the two denture adhesives with a silicone edentulous model and a resin denture base in vitro study. MATERIAL AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
THE CHANGE IN TRANSVERSE STRENGTH OF DENTURE BASE AFTER RELINE PROCEDURE

Kim SY, Vang MS

  • KMID: 1959581
  • J Korean Acad Prosthodont.
  • 1999 Dec;37(6):782-790.
The purpose of this study was to evaluate the effect of proportional thickness of various reline materials on the transverse strength of denture base. The denture base resin used in...