Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

12 results
Display

A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

Jung SC, Kim SH, Cho JY

OBJECTIVE: To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnosis of Hepatocellular Carcinoma with Gadoxetic Acid-Enhanced MRI: 2016 Consensus Recommendations of the Korean Society of Abdominal Radiology

Korean Society of Abdominal Radiology

Diagnosis of hepatocellular carcinoma (HCC) with gadoxetic acid-enhanced liver magnetic resonance imaging (MRI) poses certain unique challenges beyond the scope of current guidelines. The regional heterogeneity of HCC in demographic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Optimal scan delay depending on contrast material injection duration in abdominal multi-phase computed tomography of pancreas and liver in normal Beagle dogs

Choi SY, Lee I, Seo JW, Park HY, Choi HJ, Lee YW

This study was conducted to establish the values for optimal fixed scan delays and diagnostic scan delays associated with the bolus-tracking technique using various contrast material injection durations in canine...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Troubleshooting Arterial-Phase MR Images of Gadoxetate Disodium-Enhanced Liver

Huh J, Kim SY, Yeh BM, Lee SS, Kim KW, Wu EH, Wang ZJ, Zhao LQ, Chang WC

Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium

Feng R, Tong J, Liu X, Zhao Y, Zhang L

OBJECTIVE: To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. MATERIALS AND METHODS: One hundred and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
F-18 Sodium Fluoride Positron Emission Tomography/Computed Tomography for Detection of Thyroid Cancer Bone Metastasis Compared with Bone Scintigraphy

Lee H, Lee WW, Park SY, Kim SE

OBJECTIVE: The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy and Safety of Balloon-Occluded Retrograde Transvenous Obliteration with Sodium Tetradecyl Sulfate Liquid Sclerotherapy

Chang IS, Park SW, Kwon SY, Choe WH, Cheon YK, Shim CS, Lee TY, Kim JH

OBJECTIVE: To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. MATERIALS AND METHODS: Between February 2012 and August...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The usefulness of contrast-enhanced ultrasonography in the early detection of hepatocellular carcinoma viability after transarterial chemoembolization: pilot study

Cho YZ, Park SY, Choi EH, Baik SK, Kwon SO, Kim YJ, Cha SH, Kim MY

BACKGROUND/AIMS: The therapeutic effect of transarterial chemoembolization (TACE) against hepatocellular carcinoma (HCC) is usually assessed using multidetector computed tomography (MDCT). However, dense lipiodol depositions can mask the enhancement of viable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Triple Arterial Phase MR Imaging with Gadoxetic Acid Using a Combination of Contrast Enhanced Time Robust Angiography, Keyhole, and Viewsharing Techniques and Two-Dimensional Parallel Imaging in Comparison with Conventional Single Arterial Phase

Yoon JH, Lee JM, Yu MH, Kim EJ, Han JK

OBJECTIVE: To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tâ‚‚* Mapping from Multi-Echo Dixon Sequence on Gadoxetic Acid-Enhanced Magnetic Resonance Imaging for the Hepatic Fat Quantification: Can It Be Used for Hepatic Function Assessment?

Yoo H, Lee JM, Yoon JH, Kang HJ, Lee SM, Yang HK, Han JK

OBJECTIVE: To evaluate the diagnostic value of Tâ‚‚* mapping using 3D multi-echo Dixon gradient echo acquisition on gadoxetic acid-enhanced liver magnetic resonance imaging (MRI) as a tool to evaluate hepatic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Predictive factors of contrast-enhanced ultrasonography for the response to transarterial chemoembolization in hepatocellular carcinoma

Park KH, Kwon SH, Lee YS, Jeong SW, Jang JY, Lee SH, Kim SG, Cha SW, Kim YS, Cho YD, Kim HS, Kim BS, Kim YJ

BACKGROUND/AIMS: The predictive role of contrast-enhanced ultrasonography (CEUS) before performing transarterial chemoembolization (TACE) has not been determined. We assessed the possible predictive factors of CEUS for the response to TACE. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions

Choi TW, Lee JM, Kim JH, Yu MH, Han JK, Choi BI

OBJECTIVE: To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). MATERIALS AND METHODS: 193 patients with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr