Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

17 results
Display

The role of mammography on breast cancer patients in a hospital setting

Lee KP, Hong SJ, Oh KK, Lee KS

From Oct. 1, 1983 to May 31, 1988, 6198 mammograms were taken and 443 mastectomies were performed at the Yonsei University Hospital, Seoul, Korea. Of these, 191 cases had preoperative...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Breast Cancer Screening and Repeat Screening

Kim SH, Jeong IS, Kim JS

  • KMID: 803364
  • J Korean Acad Nurs.
  • 2004 Aug;34(5):791-800.
PURPOSE: This study was to investigate the characteristics and related factors of breast cancer screening and repeat screening, and to propose nursing interventions to increase the rate of breast cancer...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Which Phantom Is Better for Assessing the Image Quality in Full-Field Digital Mammography?: American College of Radiology Accreditation Phantom versus Digital Mammography Accreditation Phantom

Song SE, Seo BK, Yie A, Ku BK, Kim HY, Cho KR, Chung HH, Lee SH, Hwang KW

OBJECTIVE: To compare between the American College of Radiology (ACR) accreditation phantom and digital mammography accreditation phantom in assessing the image quality in full-field digital mammography (FFDM). MATERIALS AND METHODS: In...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Women's Cancer Screening According to Body Mass Index in a Cohort of Rural Korean Women

Kim BH, Koh SB, Hur HK, Park JK, Park SM

PURPOSE: This study was done to examine the difference in cancer screening with mammography and Papanicolaou smear according to Body Mass Index (BMI). METHODS: The participants in this study were 5,912...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Efficacy of Mammography Boot Camp to Improve the Performance of Radiologists

Lee EH, Jun JK, Jung SE, Kim YM, Choi N

OBJECTIVE: To evaluate the efficacy of a mammography boot camp (MBC) to improve radiologists' performance in interpreting mammograms in the National Cancer Screening Program (NCSP) in Korea. MATERIALS AND METHODS: Between...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Rates of Change to a Positive Result in Subsequent Screening Mammography in Korean Women: A Retrospective Observational Study

Bae JM, Shin SY, Kim EH, Kim YN, Nam CM

OBJECTIVES: This retrospective cohort study aimed at calculating some parameters of changes in the findings of the subsequent screening mammography (SSM) in female Korean volunteers. METHODS: The study included screenees aged...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on Scheduling Periodic Examinations for the Early Detection of Breast Cancer in Korea

Jeong SH, Kang DR, Hur NW, Kim J, Lee SY, Jung SH, Nam CM

  • KMID: 1078371
  • J Prev Med Public Health.
  • 2006 Jul;39(4):346-352.
OBJECTIVES: The purposes of this study were to propose a screening schedule for the early detection of breast cancer among Korean women, as based on the statistical model, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dosimetric Evaluation of the Mean Glandular Dose for Mammography in Korean Women: A Preliminary Report

Oh KK, Hur J, Kim EK, Choo SS

  • KMID: 2428355
  • Yonsei Med J.
  • 2003 Oct;44(5):863-868.
The purpose of this study was to evaluate the thickness of the compressed breast in mediolateral oblique (MLO) and craniocaudal (CC) mammograms, to relate these thickness and breast patterns to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance of Screening Mammography: A Report of the Alliance for Breast Cancer Screening in Korea

Lee EH, Kim KW, Kim YJ, Shin DR, Park YM, Lim HS, Park JS, Kim HW, Kim YM, Kim HJ, Jun JK

OBJECTIVE: To analyze the diagnostic accuracy and trend in screening mammography in Korea. MATERIALS AND METHODS: We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
RE: Is There a Correlation between the Presence of a Spiculated Mass on Mammogram and Luminal A Subtype Breast Cancer?

Wang RP, Xu L, Zhou S, Wang N, Tang L

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mammographic Breast Density Evaluation in Korean Women Using Fully Automated Volumetric Assessment

Youn I, Choi S, Kook SH, Choi YJ

The purpose was to present mean breast density of Korean women according to age using fully automated volumetric assessment. This study included 5,967 screening normal or benign mammograms (mean age,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Peculiar Mammographic and Ultrasonographic Findings of a Retained Silastic Drain in the Breast

Son EJ, Oh KK, Kim EK

Foreign bodies, such as surgical sponges or drains, are sometimes retained after surgical procedures.1 Retention of a drain in the breast tissue postoperatively is an unusual complication. This report describes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mammographic Density Estimation with Automated Volumetric Breast Density Measurement

Ko SY, Kim EK, Kim MJ, Moon HJ

OBJECTIVE: To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Unilateral Breast Edema: Spectrum of Etiologies and Imaging Appearances

Kwak JY, Kim EK, Chung SY, You JK, Oh KK, Lee YH, Kwon TH, Jung HK

Breast edema is defined as a mammographic pattern of skin thickening, increased parenchymal density, and interstitial marking. It can be caused by benign or malignant diseases, as a result of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pregnancy-Associated Breast Disease: Radiologic Features and Diagnostic Dilemmas

Son EJ, Oh KK, Kim EK

In this paper, we evaluate the radiological features of pregnancy-associated breast lesions and discuss the difficulties in diagnosis by imaging. We selected patients who were diagnosed with pregnancy-associated breast lesions...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Is There a Correlation between the Presence of a Spiculated Mass on Mammogram and Luminal A Subtype Breast Cancer?

Liu S, Wu XD, Xu WJ, Lin Q, Liu XJ, Li Y

OBJECTIVE: To determine whether the appearance of a spiculated mass on a mammogram is associated with luminal A subtype breast cancer and the factors that may influence the presence or...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Ultrasound-Guided Vacuum-Assisted Removal versus Surgery for Breast Lesions Showing Imaging-Histology Discordance after Ultrasound-Guided Core-Needle Biopsy

Sohn YM, Yoon JH, Kim EK, Moon HJ, Kim MJ

OBJECTIVE: To evaluate the upgrade rate and delayed false-negative results of percutaneous vacuum-assisted removal (VAR) and surgical excision in women with imaging-histologic discordance during ultrasound (US)-guided automated core needle biopsy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr