Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

14 results
Display

Lumbosacral Fixation Using the Diagonal S2 Screw for Long Fusion in Degenerative Lumbar Deformity: Technical Note Involving 13 Cases

Park YS, Kim HS, Baek SW, Lee SH

Placing instrumentation into the ilium has been shown to increase the biomechanical stability and the fusion rates, but it has some disadvantages. The diagonal S2 screw technique is an attractive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Additional Fixations for Sliding Hip Screws in Treating Unstable Pertrochanteric Femoral Fractures (AO Type 31-A2): Short-Term Clinical Results

Cho SH, Lee SH, Cho HL, Ku JH, Choi JH, Lee AJ

BACKGROUND: To evaluate the utility of additional fixation methods and to suggest a method of reduction in the treatment of unstable pertrochanteric femur fractures with a sliding hip screw (SHS). METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Early Results from Posterior Cervical Fusion with a Screw-Rod System

Kim SH, Shin DA, Yi S, Yoon DH, Kim KN, Shin HC

PURPOSE: We performed 65 cases of posterior fusion surgery for cervical and/or high thoracic lesions using a polyaxial screw-rod system. PATIENTS AND METHODS: A total of 486 screws were implanted...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Optimal Insertion Angle for Iliosacral Screw Fixation Using Three-Dimensional Computed Tomography Scans

Kim JJ, Jung CY, Eastman JG, Oh HK

BACKGROUND: Percutaneous iliosacral screw fixation can provide stable fixation with a minimally invasive surgical technique for unstable posterior pelvic ring injuries. This surgical technique is not limited by cases of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Poly-L-Lactic Acid and Poly-L-Lactic Acid/Hydroxyapatite Bioabsorbable Screws for Tibial Fixation in ACL Reconstruction: Clinical and Magnetic Resonance Imaging Results

Lee DW, Lee JW, Kim SB, Park JH, Chung KS, Ha JK, Kim JG, Kim WJ

BACKGROUND: The purpose of this study was to compare the clinical and radiological results of 2 different tibial fixations performed using bioabsorbable screws with added hydroxyapatite (HA) and pure poly-L-lactic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pedicle Screw Instrumentation for Adolescent Idiopathic Scoliosis: The Insertion Technique, the Fusion Levels and Direct Vertebral Rotation

Suk SI

The pedicle is a power nucleus of the vertebra and offers a secure grip of all 3 columns. Pedicle screw instrumentation has advantages of rigid fixation with improved three-dimensional (3D)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Breakage of a Lag Screw of Cephalomedullary Nail: A Technique of Removal

Tantigate , Riansuwan , Mahaisavariya B, Sukjaitham K

A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation

Hu Y, Pan S, Zhao X, Guo W, He M, Guo Q

OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Postoperative Changes in Paraspinal Muscle Volume: Comparison between Paramedian Interfascial and Midline Approaches for Lumbar Fusion

Hyun SJ, Kim YB, Kim YS, Park SW, Nam TK, Hong HJ, Kwon JT

In this study, we compared the paramedian interfascial approach (PIA) and the traditional midline approach (MA) for lumbar fusion to determine which approach resulted in the least amount of postoperative...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

Oh JK, Hwang JH, Varte L, Ko JH, Oh CW, Jung DY, An H, Cho JW

PURPOSE: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison between Posterolateral Fusion with Pedicle Screw Fixation and Anterior Interbody Fusion with Pedicle Screw Fixation in Adult Spondylolytic Spondylolisthesis

Suk KS, Jeon CH, Park MS, Moon SH, Kim NH, Lee HM

There have been many reports regarding various operative methods for spondylolytic spondylolisthesis. However, there have been no reports regarding the comparison between posterolateral fusion (PLF) with pedicle screw fixation (PSF)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility of Translaminar Screw Placement in Korean Population: Morphometric Analysis of Cervical Spine

Ji GY, Oh CH, Park SH, Kurniawan , Lee J, Jeon JK, Shin DA, Kim KN

PURPOSE: To analyze the feasibility of unilateral and bilateral translaminar screw placement in Koran population, and compare the acceptance rate using previously reported data in American population. MATERIALS AND METHODS: The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Arthroscopic Bioabsorbable Screw Fixation of Unstable Osteochondritis Dissecans in Adolescents: Clinical Results, Magnetic Resonance Imaging, and Second-Look Arthroscopic Findings

Chun KC, Kim KM, Jeong KJ, Lee YC, Kim JW, Chun CH

BACKGROUND: This study aimed to evaluate the clinical and radiological outcomes of arthroscopic bioabsorbable screw fixation in osteochondritis dissecans (OCD) in adolescent patients with unstable lesions causing pain. METHODS: The study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Video-Assisted Thoracoscopic Surgery for Correction of Adolescent Idiopatic Scoliosis: Comparison of 4.5 mm versus 5.5 mm Rod Constructs

Kim HS, Park JO, Nanda A, Kho PA, Kim JY, Lee HM, Moon SH, Ha JW, Ahn EK, Shin DE, Kim SJ, Moon ES

PURPOSE: The purpose of this study is to report the comparative results of thoracoscopic correction achieved via cantilever technique using a 4.5 mm thin rod and the poly-axial reduction screw...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr