Diabetes Metab J.  2025 May;49(3):436-447. 10.4093/dmj.2024.0160.

Comparison of Real-Time and Intermittently-Scanned Continuous Glucose Monitoring for Glycemic Control in Type 1 Diabetes Mellitus: Nationwide Cohort Study

Affiliations
  • 1Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
  • 2Department of Clinical Research Design and Evaluation, Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Korea

Abstract

Background
This study compares the association between real-time continuous glucose monitoring (rtCGM) and intermittently- scanned CGM (isCGM) and glycemic control in individuals with type 1 diabetes mellitus (T1DM) in a real-world setting.
Methods
Using data from the Korean National Health Insurance Service Cohort, individuals with T1DM managed by intensive insulin therapy were followed at 3-month intervals for 2 years after the initiation of CGM. The glycosylated hemoglobin (HbA1c) levels and coefficients of variation (CVs) of rtCGM and isCGM users were compared using independent two-sample t-test and a linear mixed model.
Results
The analyses considered 7,786 individuals (5,875 adults aged ≥19 years and 1,911 children and adolescents aged <19 years). Overall, a significant reduction in HbA1c level was observed after 3 months of CGM, and the effect was sustained for 2 years. The mean HbA1c level at baseline was higher in rtCGM users than in isCGM users (8.9%±2.7% vs. 8.6%±2.2%, P<0.001). However, from 3 to 24 months, rtCGM users had lower HbA1c levels than isCGM users at every time point (7.1%±1.2% vs. 7.5%±1.3% at 24 months, P<0.001 for all time points). In both adults and children, the greater reduction in HbA1c with rtCGM remained significant after adjusting for the baseline characteristics of the users. The CV also showed greater decrease with rtCGM than with isCGM.
Conclusion
In this large nationwide cohort study, the use of rtCGM was associated with a greater improvement in glycemic control, including HbA1c reduction, than the use of isCGM in both adults and children with T1DM.

Keyword

Cohort studies; Continuous glucose monitoring; Diabetes mellitus, type 1; Glycated hemoglobin; Glycemic control