Korean J Ophthalmol.  2023 Oct;37(5):387-394. 10.3341/kjo.2022.0157.

Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System

Affiliations
  • 1Institute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
  • 2Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea

Abstract

Purpose
To evaluate the effect of the Active Sentry handpiece of the Centurion Vision System compared to the Centurion Ozil handpiece for phacoemulsification in cataract surgery.
Methods
A retrospective study was conducted on 281 patients (449 eyes) who underwent cataract surgery between August 2020 and June 2021. Preoperative measurements, intraoperative parameters, complication rate, and postoperative outcomes were compared between the Active Sentry handpiece and the Centurion Ozil handpiece groups. Additionally, the parameters were compared in different cataract severity groups and multiple predictive factors for the number of active surge mitigation (ASM) actuations were assessed with the Active Sentry handpiece.
Results
There were 198 eyes in the Active Sentry group and 251 eyes in the Centurion Ozil group. There were no statistically significant differences between the two groups, as the cumulative dissipated energy in the Active Sentry and Centurion Ozil groups were 8.32 ± 7.74 and 7.87 ± 9.25 μJ, respectively (p = 0.576). Total surgery time, ultrasound usage time, aspiration time, amount of fluid aspirated, postoperative corrected distant visual acuity, and postoperative decrease in corneal endothelial cell density were comparable between the two groups. The significant contributors to the number of ASM actuations were age, preoperative corrected distant visual acuity, axial length, and total ultrasound time.
Conclusions
There was no clear advantage of the Active Sentry handpiece compared to the Centurion Ozil handpiece. ASM actuation increases with age, poor visual acuity before surgery, short axial length, and prolonged ultrasound usage time. It is expected that in more severe and high-risk cataract surgery, the Active Sentry handpiece functions more effectively, possibly affecting the safety and prognosis.

Keyword

Active fluidics; Active sentry handpiece; Cataract; Phacoemulsification; Retrospective study
Full Text Links
  • KJO
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr