Ultrasonography.  2021 Apr;40(2):217-227. 10.14366/usg.20036.

Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements

Affiliations
  • 1Department of Radiology, Seoul National University Hospital, Seoul, Korea
  • 2Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
  • 3Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea

Abstract

Purpose
This study investigated whether the use of ultrasound (US) guidance in transient elastography (TE) improved the technical success and reliability of liver stiffness (LS) measurements and whether 2-dimensional (2D) shear wave elastography (SWE) provided reliable LS measurements if TE measurements failed.
Methods
In this prospective study, 292 participants (male:female, 189:103; median age, 60 years) with chronic liver disease (CLD) were enrolled. LS was measured via the consecutive use of conventional TE, 2D-SWE, and US-guided TE. The technical success rates and reliable LS measurement rates of the three elastography techniques were compared. The risk factors for TE failure were assessed through univariate and multivariate logistic regression models.
Results
US-guided TE was associated with a higher technical success rate (281 of 292, 96.2%) and a higher reliable measurement rate (266 of 292, 91.1%) than conventional TE (technical success: 256 of 292, 87.7%; reliable measurements: 231 of 292, 79.1%; P<0.001 for both). In participants for whom conventional TE failed, 2D-SWE provided high rates of technical success (36 of 36, 100%) and reliable measurements (30 of 36, 83.3%). TE failure was associated with female sex (odds ratio [OR], 5.85; 95% confidence interval [CI], 1.30 to 26.40), severe reverberation artifacts (OR, 8.79; 95% CI, 3.93 to 19.69), and high skin-to-liver capsule depth (OR, 1.23; 95% CI, 1.09 to 1.39).
Conclusion
US guidance in TE improved the technical success and reliable measurement rates in the assessment of LS in patients with CLD. In participants for whom TE failed, subsequent 2D-SWE successfully delivered reliable LS measurements.

Keyword

Ultrasonography; Transient elastography; Shear wave elastography; Chronic liver disease
Full Text Links
  • USG
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr